Design Team Report: Acquisition and Diagnostics - PowerPoint PPT Presentation

1 / 12
About This Presentation
Title:

Design Team Report: Acquisition and Diagnostics

Description:

Acquisition time, conditions (full moon, dark sky), limiting magnitude (how faint) ... Are current calibration methods sufficient. Deliverables ... – PowerPoint PPT presentation

Number of Views:13
Avg rating:3.0/5.0
Slides: 13
Provided by: chrisn85
Category:

less

Transcript and Presenter's Notes

Title: Design Team Report: Acquisition and Diagnostics


1
Design Team Report Acquisition and Diagnostics
Christopher Neyman W. M. Keck Observatory
Keck NGAO Team Meeting 10 September 17, 2007
021 Robison Laboratory
2
Outline
  • Introduction
  • Acquisition
  • PSF camera
  • Atmospheric monitor
  • AO calibration, diagnostics, and metrology

3
Acquisition and diagnostics overview
  • Acquisition cameras to boresight science, TTFA
    and LGS sources
  • Diagnostics
  • Group of task related to AO quality assurance
    (QA)
  • All seek to answer the question Is the data
    good?
  • Assumptions temperature, humidity, cleanliness,
    status
  • These functions are part of AO enclosure and
    bench
  • AO non real-time software
  • Assumptions AO telemetry data
  • part of AO real-time software
  • Overall team plans to
  • Focus on requirements and interfaces
  • Detailed design in subsequent phases

4
Proposed AO diagnostic systems
  • PSF camera (WBS 3.2.3.12)
  • Science data calibration
  • Check on AO performance
  • Atmospheric profiler (3.2.310)
  • Science data calibration (PSF off-axis)
  • Tomography
  • Integrated with AO (3.2.3.9)
  • Radiometric calibration of instrument and AO
    focal planes
  • Astrometric calibration source
  • Point source simulator (NGSLGS)
  • Turbulence simulator
  • Alignment and registration aides
  • Metrology
  • Instrument and AO flexures, drifts, vibrations
  • Observers for parts of AO system
  • Example high speed interferometer looking at
    first DM

5
Acquisition camera
  • Lead Chris Neyman Team Neyman consult
    DLM (3.4)
  • Status
  • Planning sheet done, reviewed by team, pending
    approval
  • Inputs
  • Acquisition time, conditions (full moon, dark
    sky), limiting magnitude (how faint)
  • Requirements from science and science operations
    teams
  • Interfaces
  • Acquisition software (ACAM server, AO sequencer,
    Obs. sequencer)
  • AO bench

6
Acquisition Camera
  • Key tech issues
  • IR or visible
  • Field of view
  • Processing time
  • Optical interface
  • Deliverables
  • Predicted performance of camera
  • Design
  • Requirements and interfaces
  • Costs and risks
  • Report

7
PSF Monitor Camera
  • Lead Mathew Britton Team Matthew
    Britton
  • Status
  • Planning sheet done, reviewed by team, pending
    approval
  • Inputs
  • Performance budgets for photometry and astrometry
  • CfAO PSF study team (Flicker, Britton, LeMignant,
    Veran, Jolissaint)
  • Interfaces
  • AO software
  • AO optics, use dNIRI/LOWFS pickoffs or something
    else

8
PSF Monitor Camera
  • Key tech issues
  • Anisoplanatism
  • Non common path (need camera in second or first
    relay )
  • Sky coverage (running out of NGS 3LOWFS, 1TWFS, 1
    PSF Camera)
  • Optical interface
  • Deliverables
  • Predicted performance of camera
  • Design
  • Requirements and interfaces
  • Costs and risks
  • Report

9
Atmospheric Profiler
  • Lead Mathew Britton Team Matthew
    Britton
  • Status
  • Planning sheet done, reviewed by team, pending
    approval
  • Inputs
  • Performance budgets for photometry and astrometry
  • Requirements of tomography algorithm
  • Interfaces
  • AO software non real-time
  • AO data repository
  • Telemetry engine

10
Atmospheric Profiler
  • Key tech issues
  • Is state of the art SLODAR or MASS/DIMM
    sufficient?
  • Deliverables
  • Predicted performance of profiler
  • Design
  • Requirements and interfaces
  • Costs and risks
  • Report

11
Diagnostics, Calibration, Metrology
  • Lead Chris Neyman Team Chris
    Neyman
  • Status Planning sheet done, reviewed by team,
    pending approval
  • Inputs
  • Wavefront error budget spread sheet
  • The instrument definitions and requirements
  • Calibration requirements for OSIRIS
  • Science, system, and functional requirements
  • Interfaces
  • Optical bench
  • AO optics
  • AO software sequencer
  • AO software device control

12
Diagnostics, Calibration, Metrology
  • Key tech issues
  • Are current calibration methods sufficient
  • Deliverables
  • Predicted performance of calibration systems
  • Design or suggested vendor
  • Requirements and interfaces
  • Costs and risks
  • Report
Write a Comment
User Comments (0)