Title: LBC
1LBC Sink or Swim?Thames Valley Cytology
SocietyBedford24th June 2004
2NICE Guidance
- October 2003
- NICE recommends that LBC is used as
- the primary means of processing samples
- in the cervical screening programme in
- England and Wales
3NICE Guidance
- There is currently insufficient evidence to
- recommend one LBC product over
- another.
- The NHSCSP and SCW may wish to
- consider evaluating further different
- products as the method is introduced.
4(No Transcript)
5(No Transcript)
6Conventional Smears
- False Negative Rate of up to 55
- Sampling and interpretative errors
- Borderline Rates of up to 6.4
- 70 are truly negative
- 30 represent more severe abnormality
- Inadequate Rates of 9.7
7Sources Of False Negatives
- Sampling issues (70)
- cells not collected on the sampling device
- cells collected, but not transferred to the slide
- Interpretative issues (30)
- abnormal cells present on slide but either not
seen or misinterpreted
8The Problem
The Problem
The Conventional Cervical Smear
Non-randomized portion of cells
A cervical sample containing precancerous cells
(red)
Over 80 of cells discarded
Sample may not reflect patients actual
condition
Smear spray-fixed and sent to lab
Missing cells, obscuring elements
9The Solution
The Solution
The ThinPrep Pap Test
Virtually 100 of cells collected into ThinPrep
vial
A cervical sample containing precancerous cells
(red)
Cells immediately preserved and sent to lab
Increased opportunity to detect early signs of
abnormality
Filtration process disperses, randomizes cells
More representative and clear thin layer of
cells
10Evidence Base
Clinical Validation
ThinPrep Improvement
Patients LSIL HSIL S.Q. Split-Sample Lee et
al. 6,747 65 36 54 Corkill et
al. 1,583 110 54 N/A Roberts et al. 81,754
26 15 91 Direct-to-Vial Scottish
Pilot 30,228 92 84 76 Diaz-Rosario 56,339 72
103 ??? Papillo et al. 8,574 52
55 52 Weintraub et al. 18,247 184
94 93 Bolick 10,694 181 173 70 Johnson et
al. 902 71 125 41 Guidos/Selvaggi 9,583 267
233 97 Quddus 14,216 24
35 28 Hornish 30,431 N/A 83 N/A gt60
peer reviewed international publications from 4
Continents
11Does LBC increase sensitivity?
- Educational bias
- Lab / Smear takers
- Study design bias
- Split sample / Direct-to-Vial
- Population bias
- Self-selecting / Non-screening
- End point bias
- Dyskaryosis as surrogate / lack of histological
confirmation
12Does LBC decrease inadequate rates?
- SurePath 5000 cells
- Thinprep 40000 cells
- Conventional 50000 cells?
13Scottish Pilot Results
Weighted Average (total 30,228)
Conventional
ThinPrep Unsatisfactory 7.63
1.84 Borderline 3.98 3.67 Mild 1.10
2.12 92? Moderate 0.45
0.97 Severe 0.65 1.06 84 ?
14Scottish Pilot Conclusions
- No major storage problems
- Reduced workload for smear takers
- 349/350 smear takers preferred ThinPrep
- Increased productivity in laboratories
- Sharp reduction in the unsatisfactory rate
- Less anxiety and discomfort for women
- More appropriate referrals to colposcopy
- Allows scope for further developments
- in the screening programme
-
-
15HPV Triage
- ?Negative
- ?Borderline
- ?Mild dyskaryosis
- ?Moderate/severe
- dyskaryosis
- ?Cancer
COLPOSCOPY/ BIOPSY
HPV Testing
NO TREATMENT
16Vial storage
- Modular storage units available
- (File-a-Vial)
- 150 vial capacity
- Example
- 30,000 samples pa
- 4 week cycle
- 2,500 vials
- 17 units
17ThinPrep T2000 Processor
18ThinPrep 3000 Processor
19SurePath
- Why I like the SurePath Liquid-Based
- PAP Test
- David R Bolick
- RPS Sandy, Utah
20SurePath
- SurePath and ThinPrep
- Similarities
- Diagnostic rates
- Detection rates of HPV from vial
- Histology/Cytology correlation rates
21SurePath
- SurePath and ThinPrep
- Differences
- Inadequate rates
- False negative fraction
- Detection of abnormalities in clusters
-
22SurePath
- SurePath and ThinPrep
- Inadequate rates
-
- SurePath 0.18 26/14419
- ThinPrep 0.37 123/33198
23SurePath
- SurePath and ThinPrep
- False negative fraction
- LSIL HSIL
- SurePath 6.8 0.0
- ThinPrep 14.0 16.0
- SurePath screened TWICE ThinPrep screened ONCE
24SurePath
- SurePath and ThinPrep
- Abnormalities in clusters
- AGUS Endom Adenoca
- SurePath 0.13 0.24 0.05
- ThinPrep 0.09 0.13 0.02
25LBC
- LBC is on the way.
- 5 year conversion timescale is too long
- Major retraining exercise for labs
- Benefits in terms of productivity and scope for
future developments - Good for smear takers and women
- Issues around sensitivity / specificity /
inadequate rates will be answered in long run - Expensive solution