SUPERPHENIX 1 - PowerPoint PPT Presentation

1 / 12
About This Presentation
Title:

SUPERPHENIX 1

Description:

4 Primary Pumps. 8 Intermediate Heat Exchangers. System Components. 4 ... Ar blankets kept on top of SG and Pri Pool. Safety Systems (cont.) Automatic Shutdowns ... – PowerPoint PPT presentation

Number of Views:33
Avg rating:3.0/5.0
Slides: 13
Provided by: james458
Category:

less

Transcript and Presenter's Notes

Title: SUPERPHENIX 1


1
SUPERPHENIX 1
2
General Description
  • 3000 MWth, 1200MWe
  • Pool Type FBR
  • 4 Loops
  • 3 Circuits Per Loop

3
(No Transcript)
4
System Components
  • 4 Primary Pumps
  • 8 Intermediate Heat Exchangers

5
(No Transcript)
6
System Components
  • 4 Steam Generators
  • 2 IHXs per SG

7
(No Transcript)
8
Fuel and Control Rods
  • 24 B4C Control Rods
  • Rack Drive Gear CRDMs
  • 271 Fuel Pins per Fuel Assembly
  • 91 Fuel Pins per 238U Blanket Assembly

9
(No Transcript)
10
Safety Systems/Features
  • 4 Independent Na/Na/Air HX DHR loops w/ 4MW
    capacity each
  • H2 Detector in SG
  • 3 Circuit System Avoids Radioactive Na contacting
    water
  • Ar blankets kept on top of SG and Pri Pool

11
Safety Systems (cont.)
  • Automatic Shutdowns
  • High neutron flux/Large d/dt flux
  • High inlet/outlet temperature
  • High H2 in containment (Na/Air reaction)
  • High rad in containment
  • Low primary coolant flow
  • Earthquake

12
(No Transcript)