Title: Emanuel Karantzoulis, Alessandro Fabris,
1Status of Elettra
- Emanuel Karantzoulis, Alessandro Fabris,
- Sincrotrone Trieste, Trieste, Italy.
Acknowledgments S. Bassanese, P. Borsi, A.
Carniel, S. Krecic, M. Svandrlik, R. Visintini
2Overview /Pre-injector/Booster/Storage
ring/Conclusions
- OUTLINE
- New injector
- Pre-injector
- Booster
- Elettra performance and statistics
- Conclusions
3Overview /Pre-injector/Booster/Storage
ring/Conclusions
2008
2007
4Overview /Pre-injector/Booster/Storage
ring/Conclusions
- NEW ELETTRA INJECTOR
- GENERAL PROJECT ASSESMENT
- Project timeframe March 2005-March 2008.
- Concluded on budget and on time.
- 100 man-year of personnel matrixed to the
project. - BOOSTER MILESTONES
- Building construction September 2005 - July 2007
- Installations April 2007 - August 2007.
- Commissioning from September 2007.
- First injection for users March 3rd, 2008 as
planned.
4
5Overview /Pre-injector/Booster/Storage
ring/Conclusions
- Pre-injector energy 110 MeV maximum, 100 MeV
operating - Operating improvements
- Pre-injector synchronous with Elettra RF master
oscillator. - Safe operating conditions of pre-injector during
storms - power interruptions could damage the HV cabinet
or klystron itself. - Interruption relay of HV modulator on UPS
- Act on the thyratron trigger interlock time.
- Work in progress ( to be completed in 2008)
- Completion and test of spare modulator.
- Construction of a spare gun.
Buncher direct and reflected power vs. RF freq.
Section direct and reflected power vs. RF freq.
5
6Overview /Pre-injector/Booster/Storage
ring/Conclusions
- Booster Operational Progress
- Full energy injection at 2 GeV for users (March
3) with 3 HC tuned (ramping frequency 1.5 Hz). - 2 GeV injection with IDs at user gaps (test).
- Full energy injection at 2.4 GeV (April
13-machine shifts). - Major dipole pwr converter fault (April 16).
- Restored 2 GeV injection from August 29 (ramping
frequency 2.4 Hz). - 2.4 GeV full energy injection (November 25).
6
7Overview /Pre-injector/Booster/Storage
ring/Conclusions
- Power converters status
- Dipole 2.4 GeV _at_ 3 Hz will be tested in this
run. - Quadrupoles 2.5 GeV _at_ 3 Hz reached.
- Sextupoles delivered. To be tested on the load,
we continue to operate with the spare corrector
supplies. - Refurbishing activities (possible only during
Elettra shutdowns) - Improved layout and cards to lower interference
from EM noise, improve grounding, eliminate
communication errors. - New IGBT trigger cards embedding low level
protection to reduce number of failures and
improve functionality. - Work in progress ripple and stability.
At present X10 above
At present X3 above
7
8Overview /Pre-injector/Booster/Storage
ring/Conclusions
8
9Overview /Pre-injector/Booster/Storage
ring/Conclusions
- Maximum injection efficiency gt 95
1.0 Hz
Ratio 2.18 so 1.4/2.180.642 i.e 100
efficiency
- Booster max current above design value (5
mA/shot)
1.5 Hz
Again efficiency gt95
9
10Overview /Pre-injector/Booster/Storage
ring/Conclusions
Impact on Elettra operation
0.75 or 0.9 GeV (accelerator physics time) for
SR-FEL and SISSI CIR
10
11Overview /Pre-injector/Booster/Storage
ring/Conclusions
- RF UPGRADE
- One 150 kW plant (2 x 80 kW IOTs)
- Upgraded one of the two transmitter with a new
tube (TH793-1 from THALES) and circuit type
assembly in October 08. - Up to now IOTs lifetime is not comparable with
klystrons.
11
12Overview /Pre-injector/Booster/Storage
ring/Conclusions
Up to date 3144 scheduled hours of user
operation out of a total of 4032 (77.9)
- Up to date 3144 scheduled hours of user
operation out of a total of 4032 (77.9) - Uptime 95.3 excluding storms, 91.9 including
storms,
322 h
12
13Overview /Pre-injector/Booster/Storage
ring/Conclusions
- PRE-INJECTOR performs quite well, working to
improve. - BOOSTER
- PS are the major source of problems.
- Next steps
- Bring PSs in tolerances (and also any other
system if necessary). - Complete instrumentation.
- Increase stability and reliability.
- Reach and establish operation at 3 Hz and 2.4
GeV. - STORAGE RING
- Elettra is already showing the beneficial signs
of the full energy injection. - Next steps
- Reduce refill times to 10 minutes (reduce ID
gaps at injection, keep GOF on during refills). - Keep current above 200 mA (2 refills/day).
- Dedicate more machine shift for studies to
implement top-up.
13