Title: Options
1Options
Hardware Options
Connectivity Options
2Options
Hardware Options
Connectivity options
Low THDI option (5060kVA)
Additional RFI filters (T.B.D.)
Extended battery charger
Galvanic Isolation
Empty battery cubicles
Battery Management System
SBS
3Options
Hardware Options
Connectivity options
LIFE.net kit
LIFE.net tel. switch
PPVIS Monitoring S.W.
RAU
MopUPS
AS400 Multiplex
ManageUPSnet
4Options
Hardware Options
Connectivity options
Low THDI option (5060kVA)
Additional RFI filters (T.B.D.)
Extended battery charger
Galvanic Isolation
Empty battery cubicles
Battery Management System
SBS
5Battery Charger Current
Extended battery charger integrated into the UPS
cabinet
6Battery Charger Current
Extended battery charger integrated into the UPS
cabinet
7Options
Hardware Options
Connectivity options
Low THDI option (5060kVA)
Additional RFI filters (T.B.D.)
Extended battery charger
Galvanic Isolation
Empty battery cubicles
Battery Management System
SBS
8Options
System Bypass Switch (SBS)
- Maintenance bypass switch for parallel systems
- External cabinet
- Different models available (160A and 400A)
- Note SBS is compulsory for non redundant
configurations and for redundant
configurationswith more than 2 UPS connected.
Parallel systems with SBS
9Options
Parallel systems with SBS
Example with 2 UPS
10Options
Hardware Options
Connectivity options
Low THDI option (5060kVA)
Additional RFI filters (T.B.D.)
Extended battery charger
Galvanic Isolation
Empty battery cubicles
Battery Management System
SBS
11Options
External Galvanic Isolation
Only on demand. Standard T versions available.
Output Transformer
Input Mains Transformer
12Options
Hardware Options
Connectivity options
Low THDI option (5060kVA)
Additional RFI filters (T.B.D.)
Extended battery charger
Galvanic Isolation
Empty battery cubicles
Battery Management System
SBS
13Options
Low THDI option for 50 60kVA
- Integrated passive filter
- THDi lt 10
- Only for 50 and 60kVA
- Not available for T, LAM and I versions
14Options
Hardware Options
Connectivity options
Low THDI option (5060kVA)
Additional RFI filters (T.B.D.)
Extended battery charger
Galvanic Isolation
Empty battery cubicles
Battery Management System
SBS
15Options
Empty Battery cubicles
16Options
Hardware Options
Connectivity options
Low THDI option (5060kVA)
Additional RFI filters (T.B.D.)
Extended battery charger
Galvanic Isolation
Empty battery cubicles
Battery Management System
SBS
17Options
Battery Management System
Monitoring and Valuation
Hardware
CHLORIDE
70 NET
Battery
PPGraph
PPArchive-
Measure
-
Monitoring
/
Database
Modules
Computing
PPBatt
consists of
PPMeter
Converter
PPMeter and PPGraph
Measurement
RS232
-
Fibre Optics
- Battery Management System KNOWING THE
BATTERYS FUTURE IN ADVANCE - M By measuring the condition of each single
battery block. - D By a mouse click analysis through measurement
of minimum and maximum battery voltage. - F By finding battery problems early on.
1
2
3
Page
18Options
Battery Management System
...
1
2
3
4
...
UPS
BVM1
BVM2
...
Converter Fiber OpticsRS232
Fibre Optic Connection
Battery Voltage
RS232
RS232
Sammlung von Messdaten
Monitoring and valuation
Monitoring and Valuation
Availability
Availability
U
U
DCOM (Distributed Communication) via Network
T
T
Database
PC with Data archive Server
(MS Access-Data Base)
PC
1
2
3
Page
19Options
Battery Management System
Positive and negative examples of analysis of
single battery blocks after a discharge and
recharge cycle
- The programme
- Will check if all battery blocks provide the same
power - Will give a prognosis of battery life time after
different discharge cycles - Will save money by finding faulty blocks early on
1
2
3
Page
20Options
Hardware Options
Connectivity options
LIFE.net kit
LIFE.net tel. switch
PPVIS Monitoring S.W.
RAU
MopUPS
AS400 Multiplex
ManageUPSnet
21Remote Alarm Unit(RAU)
Options
Single UPS
- This option provides
- remote indications on
- System normal/Summary alarm
- Inverter breakdown
- Load on reserve
- No main supply
- Stop imminent
1
2
page
22Remote Alarm Unit(RAU)
Options
Parallel Systems
Available cable length
20 mt
- This option provides
- remote indications on
- System normal/Summary alarm
- Inverter breakdown
- Load on reserve
- No main supply
- Stop imminent
50 mt
100 mt
1
2
page
23Options
Hardware Options
Connectivity options
LIFE.net kit
LIFE.net tel. switch
PPVIS Monitoring S.W.
RAU
MopUPS
AS400 Multiplex
ManageUPSnet
24Options
Telephone Switch for LIFE.net
When UPS is connected via non-dedicated line For
example Telephone line shared by Fax and UPS
Life.net kit
25Options
Hardware Options
Connectivity options
LIFE.net kit
LIFE.net tel. switch
PPVIS Monitoring S.W.
RAU
MopUPS
AS400 Multiplex
ManageUPSnet
26Options
AS400 Multiplexer
To connect up to four AS400 or similar systems
One volt free contact input Four volt free
contact outputs
27Options
Hardware Options
Connectivity options
LIFE.net kit
LIFE.net tel. switch
PPVIS Monitoring S.W.
RAU
MopUPS
AS400 Multiplex
ManageUPSnet
28LIFE.net connection kit
Allows UPS to be connected to LIFE.net service
LIFE.net kit for single UPS
LIFE.net kit for parallel UPS
LIFE.net