1
Options
Hardware Options
Connectivity Options
2
Options
Hardware Options
Connectivity options
Low THDI option (5060kVA)
Additional RFI filters (T.B.D.)
Extended battery charger
Galvanic Isolation
Empty battery cubicles
Battery Management System
SBS
3
Options
Hardware Options
Connectivity options
LIFE.net kit
LIFE.net tel. switch
PPVIS Monitoring S.W.
RAU
MopUPS
AS400 Multiplex
ManageUPSnet
4
Options
Hardware Options
Connectivity options
Low THDI option (5060kVA)
Additional RFI filters (T.B.D.)
Extended battery charger
Galvanic Isolation
Empty battery cubicles
Battery Management System
SBS
5
Battery Charger Current
Extended battery charger integrated into the UPS
cabinet
6
Battery Charger Current
Extended battery charger integrated into the UPS
cabinet
7
Options
Hardware Options
Connectivity options
Low THDI option (5060kVA)
Additional RFI filters (T.B.D.)
Extended battery charger
Galvanic Isolation
Empty battery cubicles
Battery Management System
SBS
8
Options
System Bypass Switch (SBS)
  • Maintenance bypass switch for parallel systems
  • External cabinet
  • Different models available (160A and 400A)
  • Note SBS is compulsory for non redundant
    configurations and for redundant
    configurationswith more than 2 UPS connected.

Parallel systems with SBS
9
Options
Parallel systems with SBS
Example with 2 UPS
10
Options
Hardware Options
Connectivity options
Low THDI option (5060kVA)
Additional RFI filters (T.B.D.)
Extended battery charger
Galvanic Isolation
Empty battery cubicles
Battery Management System
SBS
11
Options
External Galvanic Isolation
Only on demand. Standard T versions available.
Output Transformer
Input Mains Transformer
12
Options
Hardware Options
Connectivity options
Low THDI option (5060kVA)
Additional RFI filters (T.B.D.)
Extended battery charger
Galvanic Isolation
Empty battery cubicles
Battery Management System
SBS
13
Options
Low THDI option for 50 60kVA
  • Integrated passive filter
  • THDi lt 10
  • Only for 50 and 60kVA
  • Not available for T, LAM and I versions

14
Options
Hardware Options
Connectivity options
Low THDI option (5060kVA)
Additional RFI filters (T.B.D.)
Extended battery charger
Galvanic Isolation
Empty battery cubicles
Battery Management System
SBS
15
Options
Empty Battery cubicles
16
Options
Hardware Options
Connectivity options
Low THDI option (5060kVA)
Additional RFI filters (T.B.D.)
Extended battery charger
Galvanic Isolation
Empty battery cubicles
Battery Management System
SBS
17
Options
Battery Management System
Monitoring and Valuation
Hardware
CHLORIDE
70 NET
Battery
PPGraph
PPArchive-
Measure
-
Monitoring
/
Database
Modules
Computing
PPBatt
consists of
PPMeter
Converter
PPMeter and PPGraph
Measurement
RS232
-

Fibre Optics
  • Battery Management System KNOWING THE
    BATTERYS FUTURE IN ADVANCE
  • M By measuring the condition of each single
    battery block.
  • D By a mouse click analysis through measurement
    of minimum and maximum battery voltage.
  • F By finding battery problems early on.

1
2
3
Page
18
Options
Battery Management System
...
1
2
3
4
...
UPS
BVM1
BVM2
...
Converter Fiber OpticsRS232
Fibre Optic Connection
Battery Voltage
RS232
RS232
Sammlung von Messdaten
Monitoring and valuation
Monitoring and Valuation
Availability
Availability
U
U
DCOM (Distributed Communication) via Network
T
T
Database
PC with Data archive Server
(MS Access-Data Base)
PC
1
2
3
Page
19
Options
Battery Management System
Positive and negative examples of analysis of
single battery blocks after a discharge and
recharge cycle
  • The programme
  • Will check if all battery blocks provide the same
    power
  • Will give a prognosis of battery life time after
    different discharge cycles
  • Will save money by finding faulty blocks early on

1
2
3
Page
20
Options
Hardware Options
Connectivity options
LIFE.net kit
LIFE.net tel. switch
PPVIS Monitoring S.W.
RAU
MopUPS
AS400 Multiplex
ManageUPSnet
21
Remote Alarm Unit(RAU)
Options
Single UPS
  • This option provides
  • remote indications on
  • System normal/Summary alarm
  • Inverter breakdown
  • Load on reserve
  • No main supply
  • Stop imminent

1
2
page
22
Remote Alarm Unit(RAU)
Options
Parallel Systems
Available cable length
20 mt
  • This option provides
  • remote indications on
  • System normal/Summary alarm
  • Inverter breakdown
  • Load on reserve
  • No main supply
  • Stop imminent

50 mt
100 mt
1
2
page
23
Options
Hardware Options
Connectivity options
LIFE.net kit
LIFE.net tel. switch
PPVIS Monitoring S.W.
RAU
MopUPS
AS400 Multiplex
ManageUPSnet
24
Options
Telephone Switch for LIFE.net
When UPS is connected via non-dedicated line For
example Telephone line shared by Fax and UPS
Life.net kit
25
Options
Hardware Options
Connectivity options
LIFE.net kit
LIFE.net tel. switch
PPVIS Monitoring S.W.
RAU
MopUPS
AS400 Multiplex
ManageUPSnet
26
Options
AS400 Multiplexer
To connect up to four AS400 or similar systems
One volt free contact input Four volt free
contact outputs
27
Options
Hardware Options
Connectivity options
LIFE.net kit
LIFE.net tel. switch
PPVIS Monitoring S.W.
RAU
MopUPS
AS400 Multiplex
ManageUPSnet
28
LIFE.net connection kit
Allows UPS to be connected to LIFE.net service
LIFE.net kit for single UPS
LIFE.net kit for parallel UPS
LIFE.net