L0 module on the structure - PowerPoint PPT Presentation

1 / 8
About This Presentation
Title:

L0 module on the structure

Description:

Rather long wires used to get ground connection to the ... No Faraday cage. 20V (plot above) and 60V. temperature stable _at_~35oC (may need cooling later) ... – PowerPoint PPT presentation

Number of Views:21
Avg rating:3.0/5.0
Slides: 9
Provided by: kazu76
Category:

less

Transcript and Presenter's Notes

Title: L0 module on the structure


1
L0 module on the structure
  • Two modules are installed on the sector-A

This is the first module (b)
(b)
(b)
2
Hybrid Grounding
  • Two modules have old hybrid ? no ground pad on
    the backplane

Rather long wires used to get ground connection
to the structure, especially for module (a)
(b)
(a)
3
First Result
(a)
(b)
  • No Faraday cage
  • 20V (plot above) and 60V
  • temperature stable _at_35oC (may need cooling later)

4
Noise before installation
(a)
(b)
20V bias
5
Noise after installation
20V bias
  • Noise increase very small!!
  • Only 0.5ADC count of common mode pickup in (a)
    ? due to longer wires for grounding of hybrid
    (?)

6
Noise correlation
  • Correlation between two neighbors really small

7
Even odd effect
  • Significant in (b), analog cable nearer the
    structure with 0.4-0.5mm spacer

8
Plan
  • Building 4 more modules with new hybrid, i.e.
    grounding pad on the back
  • More noise study with external noise source
  • Investigation of even-odd effect
Write a Comment
User Comments (0)