WASTE DISPOSAL FLOWCHART - PowerPoint PPT Presentation

1 / 2
About This Presentation
Title:

WASTE DISPOSAL FLOWCHART

Description:

Is waste contaminated with any material of human or animal origin? ... such as new pipet tips, empty glassware, Pasteur pipets, forceps, scissors, etc. ... – PowerPoint PPT presentation

Number of Views:42
Avg rating:3.0/5.0
Slides: 3
Provided by: Universi85
Category:

less

Transcript and Presenter's Notes

Title: WASTE DISPOSAL FLOWCHART


1
WASTE DISPOSAL FLOWCHART
Contact Radiation Safety Officer for
assistance x6771
Contact UAF Hazmat for disposal or
assistance x5617
Does the waste contain any hazardous chemicals
(formaldehyde, ethidium bromide, flammable
liquids, etc.), or is the pH of the material lt5
or gt10?
Contact Incinerator Supervisor for disposal x7020
Collect sharps in puncture-resistant container
marked Sharps.
If bacterial or viral agents are present, place
sharps container in autoclave bag and follow
Autoclaving Flowchart
If no bacterial or viral agents are present,
remove any Biohazard labels and place sharps
container in box marked Broken Glass. Seal and
dispose in regular trash.
2
AUTOCLAVING FLOWCHART
STOP! Do not autoclave these materials. Contact
EHSRM for assistance. x6771 or x5617
Do the items that you want to autoclave contain
any of the following flammable liquids
(ethanol, methanol, acetone, etc.) toxic or
reactive chemicals bleach radioactive
isotopes animal carcasses or large blocks of
tissue
Autoclave for 20 min on liquid cycle.
Place items in a tray and ensure that caps are
not tightly sealed (containers may explode).
Separate items to allow steam circulation.
Is the maximum volume in any given tube or bottle
lt500 mL?
Are you autoclaving liquids or a combination of
liquids and solid items?
Autoclave for 35 min on liquid cycle. NOTE very
large volumes may require longer times.
Is the maximum volume in any given tube or bottle
gt500 mL?
Are you autoclaving only solid items, such as new
pipet tips, empty glassware, Pasteur pipets,
forceps, scissors, etc.?
Place items on tray and ensure that any lids are
not tightly sealed. Separate objects so that
steam can circulate completely around
them. Autoclave for 20 minutes using a gravity
cycle.
Are you autoclaving solid waste in an autoclave
bag, such as contaminated agar plates, gloves,
tips, swabs?
Place bag in bin or tray. Add 100-200 mL water
to bag just prior to placing in autoclave (to
generate steam within bag during cycle). Close
bag loosely. Autoclave for 35-60 minutes using a
gravity cycle. After cycle is finished, place
bag in gray Autoclaved Waste Disposal bin next to
autoclave.
Write a Comment
User Comments (0)
About PowerShow.com