The BeamCal Simulation Project - PowerPoint PPT Presentation

About This Presentation
Title:

The BeamCal Simulation Project

Description:

We are simulating a scintillator based calorimeter where the tiles ... and be allowed to used BaBar funds deposited. in Colorado for ILC R&D work. ... – PowerPoint PPT presentation

Number of Views:24
Avg rating:3.0/5.0
Slides: 83
Provided by: nich78
Category:

less

Transcript and Presenter's Notes

Title: The BeamCal Simulation Project


1
  • The BeamCal
    Simulation Project
  • Progress Report
  • Keith Drake, Tera Dunn, Jack
    Gill,
  • Gleb Oleinik, Uriel Nauenberg
  • University of Colorado at
    Boulder

2
Beam Calorimeter Studies

Two photon process cross section about 105
larger than SUSY cross section. Serious source
of background for SUSY if not tagged .
Pointed out by our group around 1998
3

2 Photon Process
e e
Very forward into BEAMCAL
- -
?
q , l
Very forward into BEAMCAL
in the detector
?
q , l
e- e-
4

Lumi Cal
-7 mrad ent.
7 mrad exit
Beam Cal
5
  • Solenoid field keeps the low
    energy charged particle in the forward direction.
    Beam hole is at 7 mrad. Need to add an x field
    component to move low energy charged particles in
    the 7 mrad direction. Anti-DiD
  • dipole field proposed by Andrei Seryi.

6

7

Beamstrahlung ee- pairs. Energy deposited in
0.25 x0.25 cm2 cells.
8
Outside Beam Pipe
Integrated

Energy into the Beam Pipe is TeV
9
Shower in Beamcal from 2 ? process alone

side view
head-on view
core of shower
Radius of 25 mm
Radius of 25 mm
10
  • head on view

side view
beamstrahlung
electron from 2? process
11
Beamstrahlung Energy Deposition in a Tile

Tile at start of BeamCal
Tile 3.0 cm in
12
Beamstrahlung Energy Deposition in a Tile

Tile 4.7 cm in
Tile 6.0 cm in
13
  • Consequences of Beamstrahlung Energy
  • Deposition
  • Energy Deposition is not Gaussian until one
  • reaches a depth gt 3 cms.
  • Distribution is very wide and hence affects
  • energy resolution if we subtract an
    average
  • value.
  • This problem is seen in the study how to
    measure
  • the electron/positron energies.
    Resolution.

14

Electron from 2 photon overlayed
Beamstrahlung
Beamstrahlung with average subtracted
15
Clustering Cuts in Depth and Energy, Example 1

Beamstrahlung Electron from 2-photon
Beamstrahlung Alone
Cut 30 mm
Work in Progress
Cut 10 MeV
16
Clustering Cuts in Depth and Energy, Example 2

Beamstrahlung Electron from 2-photon
Beamstrahlung Alone
17
Clustering Cuts in Depth and Energy, Example 3

Beamstrahlung Electron from 2-photon
Beamstrahlung Alone
18
Energy observed as a function of distance from
center of BeamCal

f
Exit Beam Pipe
r
Entrance Beam Pipe
?f 5 deg
?r 1 mm
19
Energy Deposition versus r and f

F0.0
F30.0
30.0
Effect of Exit Beam Pipe
Effect of Exit Beam Pipe
Distance from center of beamcal (mm)
Distance from center of beamcal (mm)
20
Energy Deposition versus r and f

F150.0
F180.0
150.0
180.0
Effect of Entrance Beam Pipe
Effect of Entrance Beam Pipe
Distance from center of beamcal (mm)
Distance from center of beamcal (mm)
21

sensors
Within a radius of 25mm no clustering
Full detector
Full Detector with clustering
22
Fraction of Energy Observed within a Radius of
0.5 cm of Electron Path

No clustering cuts
With clustering cuts
23
Fraction of Energy Observed within a Radius of
1.0 cm of Electron Path

No clustering cuts
With clustering cuts
24

Fraction of Energy Observed within a Radius of
2.0 cm of Electron Path
With clustering cuts
No clustering cuts
25
Fraction of Energy Observed within a Radius of
3.0 cm of Electron Path

26
  • Energy Resolution of High Energy Electrons

E(measured)- E(expected) /E(expected)
Best Possible Resolution No Beamstrahlung effects
included
27
  • Energy Resolution of High Energy Electrons

E(measured)- E(expected) /E(expected)
Energy Resolution with Beamstrahlung
Included. Average Substracted. Only energy
deposited in a 25 mm radius from maximum. Sum
energy over full Beamcal thickness. Effect of
Beamstrhalung fluctuation in resolution clearly
has an effect
28
  • Energy Resolution of High Energy Electrons

E(measured)- E(expected) /E(expected)
Energy Resolution. Beamstrahlung Included and
Average Substracted. Measurements from 3.0 cm in
and Including only cells with more than 10 MeV
energy deposited.
29
  • Energy resolution of the reconstruction of the
    electrons from 2-photon
    events including the effects of beamstrahlung

Preliminary results
Preliminary results
Using Bayesian Statistical Analysis
30

Case of no Beamstrahlung Included in analysis
Case of Best Analysis with Beamstrahlung
Included.
Exit Beam Pipe Region
Exit Beam Pipe Region
31
  • Reason for Resolution Tail

Measured Energy loss due to cuts
32
  • Work to be Done
  • Understand the low energy tails of the energy
    resolution
  • distribution. Develop a better scan.
  • What is the missing Pt distribution of 2 photon
    events given
  • the resolution.
  • Study the resolution of new geometries.

33

34

35

36
  • Work to be Done
  • Optimize signal to Background.
  • Check all our Calculations.
  • Find other analysis techniques that reduce the
  • beamstrahlung fluctuations and hence improve
    the
  • signal resolution.
  • Study the effect of this analysis on SUSY
    signal.
  • Missing Pt limits.

37

38

39
  • Study of a Scintillator Calorimeter
  • We are simulating a scintillator based
    calorimeter where the tiles
  • are offset in alternate layers. We are making now
    a great deal of

    progress.

40

? s are well separated
5 cm
100 GeV
100 GeV
p0 mostly low p
41
ALCPG
Geometrical Arrangement
5 cm
Scintillator Panels
Worst separation
1.25 cm
?
?
?
?
f
?????
0 0.5 1.0 0.25 0.75
?
Best separation
42
Track Following into the Calorimeter

Low momentum curlers
43
Cluster Correlation with Charged Tracks Success
Probability

Energy cluster in the calorimeter associated with
a charged track interaction Success
Conclude that it is a neutral cluster Failure
44
ALCPG
  • The Chi-Square Structure
  • µi average photon energy deposited in ith
    tile
  • si standard deviation in the energy
    deposition
  • Hij si sj
  • ?2 S (xi µi )Hij (xj
    µj )
  • where xi is the energy deposited by the
    shower being tested in the ith tile.

9
-1
i,j 1
45
  • We are now in the middle of trying to separate
  • photon clusters by means of the chi-square
  • method. Hard problem. Crucial aspect of
  • pattern recognition and calorimeter resolution.

46
Fitted ? direction from shower energy
distribution

Z vs R
50 GeV
20 GeV
47
  • Study of the Characteristics of
  • Silicon Photomultipliers

48
  • New Silicon Photo-Detectors

Bias Voltage 40 volts
Photonique, SA Pulsar, Russia Moscow
Eng. Physics Inst.
2mm
Scintillator performance
49

50
2mm scint., cosmic rays

0 lt t lt 200 nsec
20 lt t lt 70 nsec
1 photo elec.
Similar resolution
5 photo elec.
Need to Improve Resolution
8 photo elec.
51

52
Sipm attached to the center of surface of the
scintillator tile

53

New Nat. Inst. PHA
54
  • Special Budgetary Issue
  • ILC RD in DOE (Paul Grannis) awarded us a
  • 20 K late award that could not be sent to CU
  • but could only be deposited at SLAC because of
  • the timing.
  • I request that I use these funds for BaBar work
  • and be allowed to used BaBar funds deposited
  • in Colorado for ILC RD work.

55
  • Because ILC RD funds become available in
  • July the funds cover 2 years of BaBar work
  • 1 year of differential housing costs for
    Nagel
  • 5 K
  • 1 year travel costs from Colorado to SLAC
  • 5 K
  • The total award from ILC RD is 53 K

56
  • The University has contributed to my research
  • a total of 38 K towards support of a Research
  • Associate since I have become Chair of the
  • Boulder Faculty Assembly and my research time
  • is now limited. I propose to use these and the
  • ILC RD funds towards the Research
  • Associate if DOE accepts the ILC-BaBar fund
  • exchange.

57
The Calorimeter
  • Modules
  • Each module 12 tons

58
Removal of Charged Track Hits

Extrapolation of charged tracks
Charged hits removed
Track Interact
Jason Gray, Jiaxin Yu
59
Pattern Recognition of Showers

Chris Geraci
60
Chi Square Separation, 1st order

Sarah Moll Joseph Proulx
100 GeV p0 Odd layers
100 GeV p0 Even layers
61

2 Photon Process
Very forward into BEAMCAL
e e
- -
?
q , l
in the detector
?
q , l
Very forward into BEAMCAL
e- e-
Discussion in Beam Cal section at end
62
  • Study the efficiency to observe
    the electron and positron of the two photon
    process above the beamstrahlung background
  • Essential to remove this background in the
  • study of Supersymmetry in the dynamic region
  • of low Pt. Needed to measure the masses.

63
Testing GEANT 4.0

Evidence for multiple scattering
air in beam pipe
No field, 50 GeV muons
No field, 50 MeVmuons
64
50 MeV, solenoid on, forward
50 MeV, no field, forward

Solenoid field shrinks mult. Scat.
65
Beamstrahlung Distribution with Solenoid
Anti-DiD

Beam pipes Entrance Exit
No beam pipes
Difficult region to detect 2 photon process
66
  • GEANT 4.0 seems to be working
  • properly We have fixed various bugs
    in
  • collaboration with SLAC team.
  • All Simulation is work in
    progress.

67
  • Hardware Studies
  • Keith Drake, Elliot Smith

68
  • Long Term Tests of Scint. Fiber Stability

69
  • Latest Pulse Distribution from
  • Photonique/Russia

6 photoelectrons
10 photoelectrons
70

Pulse National Inst.
.
.
.
.
.
.
3 pe
.
1 pe
8 pe
Scan every 2.5 nsec
71
Our Measurements

6 photo-elec.
Blue LED, 10nsec, 2.5 volts drive
50 nsec gate
noiseless SiPD
72

1st 10 nsec
2nd 10 nsec
3rd 10 nsec
4th 10 nsec
73
  • Cosmic Rays in a 1 cm Thick Scintillator

20 lt t lt 70 nsec
0 lt t lt 200 nsec
poorer resolution
1 pe
2pe
4pe
74
1cm scint

10 lt t lt 20
30 lt t lt 40
40 lt t lt 50
60 lt t lt 70
75
  • Pulse Height versus Temperature
  • Gain of SiPD Increases x4

Noisy SiPD Could not detect peaks
Room temp
-300 C
Needs to be repeated with New SiPDs noiseless
76
2 mm scint

10 lt t lt 20
30 lt t lt 40
40 lt t lt 50 nsec
60 lt t lt 70 nsec
77
  • By time tagging we are observing the
  • photons arriving in time sequence. Possibility
  • to use this to improve resolution. Need beam
    tests
  • to check this hypothesis.

78
  • Work still in progress. Comparison with
    Russian
  • plots indicate 100 Mhz x 4 (measuring pulse
    height
  • every 2.5 nsec) not enough resolution.
  • National Instruments has just released a 2
  • Gigahertz unit. Using our trick of x4 will allow
    us to
  • scan every 0.125 nsec. A demo is on its way here
    to
  • check whether 8 bits resolution is good enough.

79
  • Conclusions
  • A new revolution in photo-detection. A lot of
  • improvements still possible. A lot of work to be
  • done in this area. If one is bold and reckless
    one
  • may say that It may revolutionize calorimetry
  • resolution.

80
  • Conclusions
  • Our simulation work with the undergraduates is
  • moving ahead. A lot of work needs to be done
  • still. Need manpower help. Most of the pieces are
  • in place to study Z and W mass resolution.

81
(No Transcript)
82

We helped with the organization of the Linear
Collider Workshop and the various ALCPG
meetings up to but not including Vancouver
Write a Comment
User Comments (0)
About PowerShow.com