DAQ for Pressure Test, and later... - PowerPoint PPT Presentation

About This Presentation
Title:

DAQ for Pressure Test, and later...

Description:

1 GHz PC, 512M RAM, 20G disk. Labview, NI-DAQ. 3 National Instruments PCI ... multichannel logger. file reader. 15 March 2001. Absorber Review Meeting at NIU. 4 ... – PowerPoint PPT presentation

Number of Views:23
Avg rating:3.0/5.0
Slides: 7
Provided by: webHe
Category:
Tags: daq | later | logger | pressure | test

less

Transcript and Presenter's Notes

Title: DAQ for Pressure Test, and later...


1
DAQ for Pressure Test,and later...
  • Michael J. Haney
  • University of Illinois
  • m-haney_at_uiuc.edu

2
In Hand at UofI
  • 1 GHz PC, 512M RAM, 20G disk
  • Labview, NI-DAQ
  • 3 National Instruments PCI-MIO-16E-1
  • 1.25 MS/s, 12 bit ADC
  • 16 SE / 8 Diff analog input channels
  • 100mV - 10V (FS) programmable gain range
  • 11V max CM 25V OVP (on)

3
Enroute to UofI
  • National Instruments PCI-GPIB
  • and cables for 3 peripherals
  • GPIB software
  • Labview .VIs (work in progress)
  • multichannel logger
  • file reader

4
Enroute (elsewhere)
?
  • Keithley 220 current source
  • Keithley 7001 switch
  • Keithley 2001 multimeter
  • all are GPIB peripherals

5
DAQ Plan for Pressure Test
  • every millisecond
  • read (up to) 24 stain gauges
  • via PCI-MIO-16E-1 boards
  • common-mode permitting...
  • every second
  • read strain gauges, pressure, flow
  • all (40) channels
  • via Multimeter/GPIB

6
DAQ Plan for Pressure Test(continued)
  • Spool everything to a file
  • 10 GB / (24 12 bits 1 KHz) 77 hours
  • start and stop are moot...
  • Analyze later
  • find quasi-static measurements between fills
  • look for vibrations
  • examine rupture