Title: Controlling the ACIS FP Temperature:
1- Controlling the ACIS FP Temperature
- Turning off the DH Heater During ALL Perigee
Passages - ACIS Ops Team
2What Are We Asking For Today ?
Change to Standard Operations
- turn off the DH heater for ALL perigee passages
regardless of pitch angle
Results of Tests in FEB0408 Load
- two tests conducted during the FEB0408 load
demonstrated that it is safe to turn off the DH
heater at forward-Sun orientations, the Camera
Body temperatures never dropped below -72.2 C
3Results of the 4/5 Feb 2008 Test
Cool ACIS DH for an Entire Perigee Passage and
during E0102 observations
DePasquale (SAO), min temperature -69.8 side
A/B 63 ks at tail-Sun 48 ks at forward-Sun
4Results of the 4/5 Feb 2008 Test
FP Temperature during the test
DePasquale (SAO) Colder Camera Body results in a
colder FP temperature
5Results of the 6/7 Feb 2008 Test
Cool ACIS DH for an Entire Perigee Passage, some
E0102 observations and some HRC observations
DePasquale (SAO) Min temperature -72.2 C 59 ks
at tail-Sun 110 ks at forward-Sun Some evidence
the primary survival heater turned on
6Results of the 6/7 Feb 2008 Test
FP Temperature during the test
DePasquale (SAO)
7Summary and Conclusions of Tests at Forward-Sun
- 1CBAT and 1CBBT reached a minimum temperature of
-69.8 C in the first test after 48 ks at
forward-Sun and -72.2 C in the second test after
110 ks at forward-Sun (in both cases after
cooling for the entire perigee passage at
tail-Sun) - time constants at forward-Sun orientations are
very similar to those in tail-Sun orientations - minimum temperature of -72.2 C at forward-Sun is
consistent with Vogrins model - ACIS Fid lights are operating nominally after
these tests - it is safe to turn off the DH heater for an
entire perigee passage at any pitch angle - a cold Camera Body keeps the FP colder in
general and allows a faster recovery after
perigee passage
Future Plans
- we plan to come back to the FDB to ask for
approval to turn off the DH heater for good and
we will discuss the issue of the primary survival
heater - waiting for DS to update schedule on release of
SW which accounts for a variable Camera Body
temperature