Title: Validation of WINDOW 6 and THERM 6 for Use in Determining the Solar Heat Gain Coefficients and UFact
1Validation of WINDOW 6 and THERM 6 for Use in
Determining the Solar Heat Gain Coefficients and
U-Factors of Complex Glazing Systems Research
Project
- NFRC Project Number 07-101-RP
- NFRC 2008 Fall Membership Meeting
- William C. duPont/Sunergy Consulting
- W. Ross McCluney/Sun Pine Consulting
2Background
- WINDOW 6 and THERM 6 are currently under
development with new capabilities - Calculate the SHGC and U-Factor of
- Woven Shades,
- Venetian Blinds, and
- Fritted Glass
- Shading Systems Can Be Located
- Indoor
- Between Glazing
- Outdoor
3Project Objectives
- Perform and coordinate the data collection,
research, and testing to validate the new
features within WINDOW 6 and THERM 6
4Project Tasks and Deliverables
- Task 1 Literature Search (3 Months)
- Compile and Evaluate Existing SHGC and U-Factor
Test Results - Describe Existing Methods of Calculating SHGC and
U-Factors - Task 2 Perform Tests and Simulations (7 Months)
- Identify and Procure Test Specimens
- Perform SHGC and U-Factor Tests
- Perform SHGC and U-Factor Simulations
- Task 3 Compare and Evaluate Results (2 Months)
- Literature Search
- SHGC and U-Factor Test Results
- Task 4 Status Reports Papers (3 Months)
5Task 1 Overview
- Existing SHGC and U-Factor Test Results
- Manufacturer Product Test Results
- Pella (of 20 sets of tests, 8 sets can be
simulated) - Hunter Douglas (?)
- ASHRAE Papers and Reports
- Queens University
- Tait Solar (RP 947 6-10 Tests Center-of-Glass)
- University of Waterloo (RP 1131)
- NFRC Research Projects
- Black Blind Tilted (6 Tests at 3 Laboratories)
- Glass Block
- 7 Glazings with 9 Shades (48 Tests
Center-of-Glass) - European Research Projects
- Lund University
6Task 1 Overview(Continued)
- Existing SHGC and U-Factor Calculation
Methodologies - ASHRAE Methods
- ASHRAE 1311-RP
- Existing SHGC Load Calculation Method
- European Methods
- ISO 15099
- EN 14500 EN 14501
7Task 2a Overview
- Revision of Test Specimen List (In Collaboration
with the PMTG) - 26 SHGC Tests
- 20 U-Factor Tests
- Revised Test Specimen List
- 6 Simple Glazing System Tests
- 4 Reference Glazing
- 2 Fritted Glazing Samples (High Low Density)
- 8 Inside Shading System Tests
- 4 Woven Blinds (Loose Dense Weave, Tight
Loose Fit) - 2 Venetian Blinds (Open, 45?, Closed, High Low
Absorptance) - 10 Between-Glazing Shading System Tests
- 2 Woven Blinds
- 3 Venetian Blinds (Open, 45?, Closed, Thin
Thick Pane Spacing, High Low Absorptance) - 1 Retracted (Venetian Blind)
- 2 Outside Shading System Tests
- 2 Sunscreen (Loose and Dense Weave, High Low
Absorptance)
8Task 2b Overview(Continued)
- Procure Test Specimens
- Donation of Windows, Glazing and Shades
- Marvin Windows and Doors
- Pella Corporation
- Viracon
- Glen Raven Custom Fabrics
- Phifer Wire
- Hunter Douglas
- Need to Identify Glazing Layer with Properties of
Shade
9Task 2b Overview(Continued)
- Metal Frame Window
- Similar to Proposed Base Case Metal Frame Window
- Designed by PI using common components
- Built by ATI
- Single-Glazed Clear
- Inside Woven Shade
- 2 Fritted Glass IG
10Task 2b Overview
- Perform SHGC Tests
- Develop Statement of Work for SHGC Testing (NFRC
Contract) - Architectural Testing, Inc. in Fresno, CA (ATI)
chosen as NFRC 201 Accredited Testing Laboratory - SHGC Testing started October 6, 2008
- PI Visit ATI during the week of October 6-10, 2008
11Task 2b Overview(Continued)
- Installation of Fenestration Attachments
- SHGC and U-Factor Tests on Identical Specimens
- Sometimes Difficult to Install Attachments at a
Tilt - Shade Materials Sag out of Co-planer Orientation
- Shade Supports shall have Minimum Impact on SHGG
and U-Factor Testing - Venetian Blinds
- Between Glazing use 2 Vertical Clear Acrylic
Square Rods (1/8, ¼ ½) glued to Inside Glass - Indoor use Tightly Strung Monofilament
- Woven Shades
- Mounted on ½ x ¾ Wooden Frame (Painters
Canvas) - Installation Verified by PI
12Task 2b Overview(Continued)
13Task 2b Overview(Continued)
- Instrumentation of Calorimeter and Test Specimens
- Added Temperature Sensors To Specimen
- Modified Means of Attaching Temperature Sensors
to Glass - Indicated Temperature Sensor Locations on Windows
- Modified Air Temperature Radiation Shield
- Verified Tracking
- Solar Time
- Off-Normal Indicator
- Need to Retrieve Atmospheric Data to Adjust Solar
Spectrum
14Task 2b Overview(Continued)
15Task 2b Overview(Continued)
16Task 2b Overview(Continued)
- Perform U-Factor Tests
- Develop RFP for U-Factor Testing (NFRC Contract)
- Primary NFRC 102 Laboratory (All Tests)
- Architectural Testing, Inc. in Fresno, CA (ATI)
- Secondary NFRC 102 Laboratories (Two Tests Each)
- Architectural Testing, Inc. in St. Paul, MI
- Architectural Testing, Inc. in York, PA
- U-Factor Testing started October 3, 2008
- PI Visit ATI during the week of October 6-10, 2008
17Task 2b Overview(Continued)
18Task 2c Overview
- Perform SHGC and U-Factor Simulations
- Develop RFP for SHGC Testing (NFRC Contract)
- Response from 2 Laboratories
- Carli, Inc.
- ETC Laboratories
- Carli, Inc. (Carli) Chosen as NFRC 100 and NFRC
200 Simulation Laboratory - Simulated as Tested
- As Installed in Solar Calorimeter or Thermal
Chamber - At Environmental Conditions Experienced During
Testing - Simulation of New Test Results
- Window Manufactures have donated THERM files
- Simulation of Old Test Results
- More Potential Comparisons than Expected
- Some Center-of-Glass only
- Negotiating Final Contract at this meeting
19Current Tasks
- Follow-up with Optical Properties Test Results
for addition to Shading Systems Library - Shade Manufacturers Have Donated Test Results
- Start to Compile and Analyze Test Results
- Start Simulations...
20A Happy Scientist!