Title: Control and regulation of boiler operation


1
Control and regulation of boiler operation
  • Heat Engines Boilers

2
Contents
  • Hot- and warm water boiler operation controland
    safety limits
  • Domestic heating and hot water generation control
  • Hot- and warm water boiler operation controland
    safety limits- Spray type superheat control-
    Water level control
  • Boiler controls for operation without permanent
    supervision
  • Steam supply system principals
  • Steam traps

3
Hot- and warm water boiler operation control
Thermal oil boiler control is similar
  • In these type of systems there is not phase
    change only heating up of heat transfer medium
    happens. Useful heat can be expressed according
    to following expression.
  • Quseful mwater ? c ?( tout tin )
  • Heat supply is controlled mainly by two ways-
    In case of quantity control inlet and outlet
    temperature level constant and mass flow rate of
    heat transfer medium is modified - In case of
    quality control inlet and outlet temperature
    level modified and mass flow rate of heat
    transfer medium is constant
  • Power level control happens generally from outlet
    temperature of the boiler(Power level control
    means burning fuel control done generally by
    fuel inlet quantity control)

4
Safety limits
  • Maximal outlet temperature
  • Minimal inlet temperature(in case of non
    condensing boilers)
  • Overpressure limitation
  • Heat transfer medium absence limitation
  • Minimal flow limitation

5
Domestic heating system control
6
Heating water temperature variation
7
Domestic heating and hot water generation control
8
Steam generator operation control
  • In case of steam generator useful heat can be
    calculated according to following expression
  • Quseful msteam ? ( hout hin )
  • Heat demand variation results variation of steam
    mass flow rate. Mass flow rate variation at
    constant power level and at constant feed water
    parameters results outlet enthalpy and outlet
    pressure variation.
  • Power level control happens generally by means of
    outlet pressure control, because of previously
    detailed phenomena.(Power level control means
    burning fuel control done generally by fuel
    inlet quantity control)

9
Outlet temperature control
  • In case of saturated steam outlet temperature is
    not needs to be controlled, because outlet
    temperature is determined by saturation
    condition.
  • But in case of superheated steam generation
    superheat temperature is affected by load
    conditions, and several operation parameters, so
    it needs to be controlled.
  • Earlier several methods were used for superheat
    temperature control,
  • but nowadays only spray type superheat control is
    used.

10
Spray type superheat control
  • Of all the direct contact types, the spray
    attemperator has proved most satisfactory.
  • Water of high purity is injected directed into
    the superheated steam main or into a mingling
    chamber.
  • The water is sprayed in through a series of
    nozzles at the throat of a venturi section,
    forming a fine mist.
  • It is quickly vaporized and first mixes with and
    then cools the superheated steam. The design must
    include a thermal sleeve to protect the piping
    from thermal shock caused by water droplets
    striking the hot surface.

11
Spray at different locationsfor outlet steam
temperature controlat the boiler outlet in
between two superheater
12
Installation of a spray type attemperator
13
Installation of a spray type attemperator
14
Typical injector construction of spray type
attemperators
15
Feed water quantity control
  • According to actual evaporated water quantity the
    same amount of feed water needs to be fed into
    the boiler.
  • Generally water level in the drum is used for
    this task.
  • In case of once-through type boilers it has to be
    connected with power level control.

16
Water level sensors
17
Water quality control
  • At any type of water treatment a certain amount
    of salt is delivered to the boiler with feed
    water.
  • But the steam delivers nearly any salt out from
    the boiler.
  • So salt is accumulated in boiler water. Over a
    certain concentration it can cause operation
    troubles e.g. foaming of water, etc.
  • So salt concentration needs to be held below a
    certain concentration level.
  • This is solved by letting out some boiler water
    quantity, which is called slugging or
    desalination. Fresh feed water will reduce salt
    concentration

18
General safety limitations
  • Maximal outlet pressure is generally limited by
    both- electronic and - mechanical way with
    safety valves
  • Maximal outlet temperature
  • Water level limitation- minimal more important-
    maximal less important
  • Boiler water quality limitation- salt
    concentration by means of water conductivity

19
Boiler operation supervision
  • In general case boiler operation is potential
    danger, so it needs continuous attendance to
    supervise.
  • With fulfilling special requirements boiler can
    be operated without permanent attendance. But it
    does not mean without attendance, it means only
    that supervisor visit needs to be held regularly,
    and not continuously.
  • Special requirement means that boiler has to be
    protected automatically from all the possible
    dangerous operation condition

20
Boiler controls
21
Shell boilers controls
22
Condensate monitoring for salt and oil pollution
23
Boiler and auxiliary controls
24
Steam supply system principals
25
Flash steam formation
26
Flash steam formation
27
Example for steam trap installation
28
Float steam trap
29
Operation of a thermodynamic steam trap
30
Operation of a bimetal steam trap
31
Termic steam trap
32
Summary
  • You are already familiar with
  • Hot- and warm water boiler operation controland
    safety limits
  • Domestic heating and hot water generation control
  • Hot- and warm water boiler operation controland
    safety limits- Spray type superheat control-
    Water level control
  • Boiler controls for operation without permanent
    supervision
  • Steam supply system principals
  • Steam traps

33