Title: External Control
1by
External Control Overview
2nion control i/o
25 pin GPIO connector
Serial control port
Ethernet jack
Serial bridging via CobraNet (RS-485)
3GPIO Dialog Boxes
NioNode
CAB 4n
Not a selection in Properties, always available
on GPIO Tab
4nion GPIO
- Up to 16 User Configurable
- Low Voltage/Current GIO
- AS..
- 16 Digital Input Or Output
- 0.8 - 2.0VDC TTL Input
- 3.3VDC TTL Output
- Up To 8 Rotary Encoders
5nion GPIO
- Up to 16 User Configurable
- Low Voltage/Current GIO
- AS..
- 16 Analog Input
- 0 - 24VDC input with 12 Bit Precision
- 1k Or 10K Potentiometer
- External Or Self Powered (to ground)
-
6nion GPIO
- Up to 16 User Configurable
- Low Voltage/Current GIO
- AS..
- Three Clock Outputs On Select GIO
- One each
- Word/Brick/Frame Clock
7nion GPIO
- PLUS
- Four High Current Outputs
- 500mA _at_ 11.5VDC
- Configurable as PWM
- AND
- ONE SPDT Fault Relay
8cab4n GPIO
- 8 Analog Or Digital I/O
- 4 SPDT Relays
- 1 SPDT Fault Relay
9GPIO-25
- DB-25 to Euro-Connectors Break Out
- 4 DIN Rail
- 3 Cable
10Driving An LED With A Digital Output
12VDC
GPIO Digital Output
Series Resistance As Needed To Protect Transistor
LED
1k 1/4W
General Purpose NPN Transistor Gain 100
This diagram is for general reference only and
should not be used in system design.
11Driving A Relay Coil With GPIO
12VDC
12 VDC Relay Coil Imax lt100mA
1N4003
GPIO Digital Output
Series Resistance As Needed To Protect Transistor
1k 1/4W
General Purpose NPN Transistor Gain 100
ALWAYS Use A Flyback Diode On A Relay Coil! It
Prevents Back EMF From Destroying The Switching
Transistor.
This diagram is for general reference only and
should not be used in system design.
12Serial Control
- Control Protocols
- RS422, RS485, RS232
- Standard ASCII Text Strings
- PASHA, X-Net AND RATC2
- Control Alias
- Replaces Control Groups
- Improved User Interface
- Supports Long Alias Names
- Case Sensitive
- No Spaces Allowed
- PASHA And X-Net Still Use Three Character Alias
13Nion Serial Control Port
- DB9 on the rear of the unit.
- Unique pinout - be careful.
- RS422/485 operation.
- Integral 120 ohm terminators.
- Use pins 1 2 for RS485 (1, 2-).
- Supplies 12VDC _at_ 500mA
- for XControls.
14Control Via TCP/IP
- RATC And RATC2
- Both Supported
- Re-Use Existing Control Systems
- RATC Type Must Be Selected During Design (NioNode
Properties) - RATC2 - Improved User Interface
- Shorter Commands
- Type h For Command List
15RATC2 Telnet Session
16Control Via TCP/IP
17NWare Kiosk
18CONtrol MANager
- SNMP Functions (Currently not factory supported)
- Offload Control Duties From NIONs
- Control Third Party Products (Currently not
factory supported)
19THE ENDBesides, who likes lookingat PowerPoint
all day? Lets DO something!Even if its
wrong.
20(No Transcript)