Title: Subtrochanteric Fractures
1Subtrochanteric Fractures Sliding Plate
Fixations Peter Biberthaler LMU-Innenstadt Münche
n
2Aims
- Plate options
- Biomechanics
- Indications
- Surgical technique
- Cases
- Results in Literature
3Plate Options
- Condylar plate 95
- Dynamic compression screw 95
- Dynamic hip screw 135
4Plate Options
DHS
Condyle
DCS
5Biomechanics
A m. gluteus medius B m. ileopsoas C adductor
group (Adapted from Russell TA,
Taylor JC subtrochanteric fractures of the femur
in Browner BD, Jupiter JB and Levine AM editors.
Skeletal trauma 2nd edition Philadelphia PA, WB
Saunders 1992, p1836, drawing by Hella Thun)
6Classifications
AO 31A3
Seinsheimer
Russel-Taylor
7Surgery patient and C-Arm placement
8Surgical technique 95-condyle-plate
9Surgical technique 95-condyle-plate
Insertion of blade
Anterior 1/3 of femoral neck
Maintainance of reduction
Very carefully alignement to the shaft axis
10Surgical technique 95-condyle-plate
Insertion of plate
Fixation by screws
11Cases
Male, 35a, high energy impact accident Open
fracture Long ICU stabilization period
12Cases
Female, 65a, max. obesity
13Cases
Male, 58a, incompliance Salvage procedure for
failed IM
14Limitations
15Handicaps of the 95 condylar plate
- Extensive soft tissue
- detachment required
- for precise placement
- to the shaft
- Requires surgical
- expertise
- Long leather arm
16Results Data literature
Lundy, JOT 1999 Technical requirements of
implantations requires wide soft tissue
detachment, impaired bone healing 95-Condylar
plate is limited by long leather
arm/bending Bedi, 2004, Orthop Clin North
Am Craig, Disabil Rehab 2005 Race between bone
healing and plate breakage
- 95 Condylar plate limited to
- Heavily contaminated open fractures
- Very obese patients with technical impossibility
of correct nail insertion - Too narrow medullar space for nails
17Dynamic Compression Plate
- Combines sliding mechanism
- with 95 stronghold
- Technically less demanding but..
- Still unfavorable leather arm
18Cases
19Results Data literature
Lundy, JOT 1999 95 Dynamic compression plate
requires less soft tissue detachment and is
easier to handle but still has a bad leather
armBedi, 2004, Orthop Clin North Am
- 95 Dynamic Compression Plate
- Similar to Condyle plate
- Second/third choice
20Dynamic Hip Screw
21Conclusion
- Sliding plates were the first implants for better
results for surgery as compared to conservative
treatment - Current data supports implantation only for
special indications - Multiple injury, wide open fractures, long
stabilization period with Fix. Ex. - Max. Obesity
- Contraindications for IM
- Salvage procedure for failed IM