1. dia - PowerPoint PPT Presentation

About This Presentation
Title:

1. dia

Description:

Development of reconstruction software for the 3DXRD method. Indexing ... Low and high resolution 3D-reconstruction of the initial state (M9) ... Topo-tomography ... – PowerPoint PPT presentation

Number of Views:36
Avg rating:3.0/5.0
Slides: 20
Provided by: borbely
Category:
Tags: dia | tomography

less

Transcript and Presenter's Notes

Title: 1. dia


1
WP5 at the midterm meeting András Borbély, ELTE
  • What has been done
  • Development of reconstruction software for the
    3DXRD method
  • Indexing
  • Refinement (low resolution reconstruction)
  • High resolution reconstruction
  • Application to a model structure
  • Application to the real material (Al-0.5Mg)
  • Software development for the evaluation of
    experimental data

2
Deliverables
  • Low and high resolution 3D-reconstruction of the
    initial state (M9).
  • Ex situ and in situ deformation, evaluation of
    dislocation densities (M18).
  • None of them could be produced!

3
3DXRD microscopy
  • E. M. Lauridsen, S. Schmidt, R. M. Suter and H.
    F. Poulsen, J. Appl. Cryst. (2001) 34.

4
  • Indexing
  • Identification of Sensicam spots
  • Reconstruction

(x,y)
Sensicam (1.3 ?m)
Frelon, low resolution detector (50 ?m)
5
A measure for the goodness of reconstructed
parameters, output of indexing
6
How large is the error of the experimental data?
7
How large is the error of grain centers?
8
Model structure, best possible reconstruction
(5?m)
y ?m
FOM 0.96
x ?m
9
No additional error. Indexing based on Frelon
No additional error. Indexing based on Sensicam
FOM 0.92
FOM 0.7
10
The influence of errors
? 1 pixel (Frelon)
  • 1 pixel (Sensicam)

FOM 0.90
FOM 0.54
11
Plan for the next 6 months
  • Software development for high resolution peak
    identification
  • New indexing software with high resolution data,
    considering all 5 parameters
  • (2-position, 3-orientation)

12
Deliverables to be produced
  • Reconstruction of the 3D structure layer-by-layer
    (probably not easy, due to the absence of
    publications containing such reconstructions)
  • Evolution of dislocation density in plane-strain
    compressed samples. Comparison between in situ
    and statistical evaluations. (Availability of
    ESRF for the in situ measurement)

13
Problems with the experimental data
14
(No Transcript)
15
(No Transcript)
16
(No Transcript)
17
(No Transcript)
18
(No Transcript)
19
Topo-tomographyan alternative method for the
nondeformed and recrystallized states, W. Ludwig
(INSA, ESRF)
Write a Comment
User Comments (0)
About PowerShow.com