FFSP-0003
2
  • Peace of Mind
  • The OneSump provides the highest level of
    environmental protection by minimizing the leak
    paths to the environment
  • Installation Tank OpeningsDirect
    bury 6Multiport 2Onesump 1
  • OneSump means less equipment to purchase and
    faster installation, saving you both time and
    money

3
  • Everything in One Enclosure
  • The OneSump secondarily contains
  • Fill port spill containment
  • Vent risers
  • Turbine
  • Probe riser
  • 15 gallon spill containment bowl
  • No need to install additional turbine sump
  • No need to install additional probe manhole

4
  • Added Protection
  • The large 15 gallon spill containment bowl
    provides maximum room for spills
  • In the event that the spill were to exceed 15
    gallons, overfill is diverted to the tank top
    containment sump rather than at grade as with
    conventional spill bucket design
  • In extreme overfill events, this effectively
    turns the OneSump into a 200 gallon spill
    containment system

5
  • Easy Installation
  • Complete system can be fully installed by one or
    two technicians
  • Flanged system dramatically reduces installation
    time by eliminating many field piping cuts and in
    sump wrenching
  • Unnecessary turbine sump is eliminated, reducing
    installation time and cost

6
  • Easy Installation
  • Flanged extractor vent provides 360 degree
    directional adjustment while installed
  • Installation tool installs flange adaptors onto
    manway to maintain flange seal surface integrity

Installation Tool
7
  • Easy Installation
  • Fill drop tube and overfill prevention valve
    installed through flanged fill riser extractor
    vent
  • Allows for ullage of tank to remain isolated from
    the drain valve

8
1. Remove Cover
2. Remove Drip Caps
3. Remove Spill Bowl
4. Remove Drain Connection
5. Access Sump
9
  • Easy Access
  • Single technician can access tank manway in
    minutes
  • Complete system can be removed without the need
    for a pipe wrench

10
  • Installation Flexibility
  • SS flex lines, Viton gaskets and single pin
    clamps used for product and vent piping
    connections make for simple maintenance and easy
    access
  • Loosen clamps to pivot assembly, then retighten
    when desired direction is met

11
  • Let Us Help You Customize
  • Site specific packages fully customized to meet
    customer needs
  • Single package part number for ease of ordering
  • Full color drawings provided for on site reference

12