L. Staykov - PowerPoint PPT Presentation

1 / 13
About This Presentation
Title:

L. Staykov

Description:

YAG screens. Emittance Measurement SYstem. EMSY. Based upon slit technique (pepper pot) ... OTR and YAG screens installed. Newport motors and motion controller ... – PowerPoint PPT presentation

Number of Views:41
Avg rating:3.0/5.0
Slides: 14
Provided by: desy
Category:
Tags: staykov | yag

less

Transcript and Presenter's Notes

Title: L. Staykov


1
EMSY status report
  • L. Staykov
  • PITZ collaboration meeting 2006.09.05

2
TALK outline
  • EMSY what, where and when
  • EMSY layout
  • PITZ and EMSY
  • Commissioning of the device
  • Whats next
  • Conclusions

3
Emittance Measurement SYstemEMSY
  • Based upon slit technique (pepper pot)
  • Tungsten slit, width of 10 mm
  • OTR and YAG screens installed
  • Newport motors and motion controller
  • YAG screen used for beamlet observation
  • remote zoom optics tested

4
PITZ and EMSY
  • Three new EMSYs are produced by HITECH HEP Group
    in INRNE Sofia
  • Construction and successful vacuum and mechanical
    test done end of May
  • June installed in the tunnel in positions 4.3,
    6.6 and 9.8 m
  • Only the first system aligned
  • All installed components are working properly

5
Commissioningbeam trough
6
Commissioningscreen performance
  • Image from the OTR screen of EMSY1
  • 180 laser pulses
  • 1 nC

7
Commissioningscreen performance
  • Image from the YAG screen of EMSY1
  • 1 nC
  • 2 laser pulses

8
Commissioningscreen performance
  • Radiation noise from the camera at the screen of
    beamlet observation
  • Slit is inserted
  • Screen is removed

9
Commissioningfirst emittance
  • 50 frames, 35 laser pulses
  • 1 nC (8.4 )
  • ref. gun phase 0
  • ref. boo phase 0
  • Imain 295 A
  • Y normalized emittance 1.33 mm mrad
  • 50 frames, 120 laser pulses
  • 1 nC (8.4 )
  • gun phase 0
  • booster phase 0
  • Imain 295 A
  • X normalized emittance 1.1 mm mrad

Preliminary!!!
10
Commissioningnext emittance
  • 50 frames, 30 laser pulses
  • 1 nC (17 )
  • gun phase 0
  • boo phase 0
  • Imain 295 A
  • X normalized emittance 1.87 mm mrad
  • Optimization of the angular orientation of the 10
    mm slit

Preliminary!!!
11
Commissioningangular orientation
  • Optimization of the angular orientation of the 10
    mm slit

12
Whats next
  • Emittance measurements
  • Multi slit masks are produced
  • To be delivered at the end of September
  • Installation follows

13
Summary
  • All the installed components are working fine
  • Remote zoom lenses have too low light
    transmission
  • Good charge transmission from the 10 mm slit
  • System is ready for use
  • Thanks for your attention