1
VRBCs
  • Old VRBCs no spares
  • VRBC in crate 0x53 stopped working on 8-May
  • New VRBCs either do not work or are flaky
  • Quoting Don Femilab engineers are busy working
    on reducing event readout time

2
Flaky new VRBCs
  • Compromise data taking
  • Missing event
  • Garbled data
  • Take our time
  • We devote our time to monitor their work
  • Prolong calibration time because of stale data

3
Missing Events
  • When notified by DAQ shifter that one of out
    crates has missing events
  • click on init VRBC. No need to pause the
    run.
  • Please ask DAQ shifter not to issue SCL init to
    fix missing events.

4
New VRBCs Stale data
  • LED induced spectra

5
New VRBCs Stale data
  • LED induced spectra with stale data

6
New VRBC in 0x5220-May-2003
  • CFT_log 207059 25-May-2003
  • Hit maps okay
  • Re-downloading 0x51 and 0x52 fixed the problem

7
Please watch pdaq_examine
  • Here one needs init VRBC for crate 52.
    Typically errors suddenly will start coming for
    each event, try to init VRBC as soon as you
    notice that.
  • Please also document in logbook

8
Please watch pdaq_examine
  • This situation would require init VRBC for
    crate 0x53. Typically errors suddenly will start
    coming for each event, try to init VRBC as soon
    as you notice that.
  • Please also document in logbook

9
New cft_examine
10
SVX threshold change
  • 4B7 module 5
  • 6A5 module 8

11
Large RMS 4B7, module 5
12
4B7 Pulse Height
13
4B7
  • Large RMS in 4B7 due to light leak

14
Large RMS 6A5 module 8
15
6A5 Pulse Height
16
Temperature 6A5, Module 8
17
Temperature 6A5 Module 8
18
Bias 6A5 Module 8
19
Bias 6A5 Module 8
20
6A5
  • Light leak

21
  • Hit map

22
New cft_examine
  • Bug in offline