S8910U1000 Universal Electronic Ignition Modules Training Module - PowerPoint PPT Presentation

1 / 27
About This Presentation
Title:

S8910U1000 Universal Electronic Ignition Modules Training Module

Description:

There are 3 different ways a burner can be ignited: 1) Standing Pilot Ignition ... delivered, check for overheating of the igniter/sensor, flame rod ceramic or ... – PowerPoint PPT presentation

Number of Views:667
Avg rating:3.0/5.0
Slides: 28
Provided by: dbot7
Category:

less

Transcript and Presenter's Notes

Title: S8910U1000 Universal Electronic Ignition Modules Training Module


1
S8910U1000Universal Electronic Ignition Modules
Training Module
2
What you will learn
  • Ignition Types
  • S8910U1000
  • Features and Benefits
  • Installation and Set Up
  • Troubleshooting
  • S8910U Advantage
  • Product Cross Reference Information

3
Ignition Sources
  • There are 3 different ways a burner can be
    ignited
  • 1) Standing Pilot Ignition
  • 2) Intermittent Pilot Ignition
  • Intermittent Pilot - S8610U
  • 3) Direct Burner Ignition
  • Hot Surface Ignition S8910U
  • Direct Spark Ignition S87

4
S8910U1000
5
Universal Hot Surface Ignition Module
  • What is the S8910U1000?
  • Electronic control of direct hot surface Ignition
    systems used on gas fired furnaces, boilers, and
    other heating appliances
  • Operating control of a direct ignition system
    using a 120 Vac hot surface igniter
  • No spark generator
  • Simple relay to power igniter
  • Two wires to gas valve

One Part Number S8910U1000
6
S8910U Features The Universal Choice
  • Features
  • Universal Compatibility
  • Replaces over 100 Honeywell and competitor
    models.
  • Personality Plug-Ins- match the ignition
    sequence of the model being replaced using the
    plug in selector tabs and cross reference chart
    for an instant equivalent of the old control.
  • Application Flexibility
  • Use with Single Rod or Dual Rod Systems
  • Works with both Natural or LP gas
  • Easy Installation
  • Easy-to-use instructions plus the adaptation
    accessories required to adapt the existing hot
    surface ignition module
  • Accessory kit includes White-Rodgers adapter,
    Robertshaw ground lead, four ¼ female .032
    quick-connects, one 3/16 female .032 quick
    connects, four selection tabs and seven wire
    labels.

7
The Universal Choice continued..
  • LED diagnostics
  • Quickly troubleshoot and diagnose any problems
    with the system
  • Ignition Trials
  • Provides one or three ignition trials (4-second
    or 7-second trials) per call for heat
  • Prepurge of 32-seconds or less
  • Up to 90-seconds between purge cycle times
  • Excellent industry acceptance
  • The Honeywell brand is recognized as a top
    performer in the industry

8
S8910U Features
BRN/GND
LED
24 GND
SENSE
MV
MV
24 V
IGNITION TRIAL SELECTOR TAB
SENSE JUMPER WIRE
HOT SURFACE IGNITER
9
Installation and Set Up
10
Installation of the S8910U
  • Mount the module
  • Do not mount with terminals facing up
  • protect the module from exposure to water,
    moisture, corrosive chemicals and excessive dust
    and grease.
  • Install selection tab (personality plug-ins)
  • The number of trials for ignition and trial time
    is determined by the selection tabs.
  • Four selection tabs are included with the S8910U.
    (A,B,C,D)
  • Without a selection tab, the module operates at
    four-second trial time and one ignition.
  • Selection tabs A and B 4 seconds.
  • Selection tabs C and D 7 seconds.
  • Wire the module
  • Use diagrams in installation instructions for
    wiring

11
Selection Tab Installation
  • See Tables 1 through 3 in installation
    instructions (Form 68-1061) for correct tab
    selection.
  • Select and Install the correct tab, push firmly
    in place and discard the remaining tabs.

12
Selection Tab Cross Reference
13
Select Timing Tries
GND 24V VALVE 24V LED VALVE L2 HSI
L1 HSI SENSE
! WARNING
Honeywell
S8910U HOT SURFACE IGNITION
TRIAL 7 SEC 1 TRY (C)
14
Troubleshooting
15
LED Indicator Light
LED
GND 24V VALVE 24V LED VALVE L2 HSI
L1 HSI SENSE
! WARNING
  • Flashes Meaning
  • Pulse Normal operation
  • 1 Lockout
  • 2 Flame signal
  • 3 Internal

Honeywell
S8910U HOT SURFACE IGNITION
16
Troubleshooting of the S8910U
  • LED shows system status for the current call for
    heat
  • Pulsing heartbeat is the normal operating mode
    during a call for heat (24V terminal is powered).
    The system can be in any of the normal operating
    modes including prepurge, warm-up, ignition
    trial, between trial purge, or normal run.
  • One flash indicates the S8910U is in an ignition
    lockout mode. The most probable cause is the main
    burner failing to light or failure to detect the
    flame. Run the appliance through a call for heat
    and if the burner does not light, check the
  • gas supply
  • input voltage
  • hot surface igniter
  • gas control
  • Wiring
  • If the main burner lights, but goes out at the
    end of ignition trial, check the
  • igniter/sensor
  • flame rod
  • burner ground connections
  • wiring

17
Troubleshooting of the S8910U
  • LED Continued
  • Two flashes indicates the flame rectification
    signal is weak. The most probable causes are
  • contaminated or mis-located igniter/sensor or
    flame rod
  • poor flame sense lead-wire insulation or
    connections
  • poor gas pressure
  • If the flame rectification signal is strong when
    the appliance lights, but weak while heat is
    being delivered, check for overheating of the
    igniter/sensor, flame rod ceramic or flame sense
    leadwires.
  • Three flashes indicate an internal error. The
    most probable cause is an S8910U logic failure.
    Start a new call for heat and if the three-flash
    signal returns, replace the S8910U.

18
Product Cross Reference
19
Product Cross Reference
  • Where do I find Honeywell electronic ignition
    cross reference and selection information?
  • www.customer.honeywell.com
  • Honeywell Application Selection and Cross
  • Reference Guide Form 63-9575
  • Honeywell Laminated Truck Visor Form 63-9581
  • Honeywell Gas Counter Mat Form 63-9580
  • Honeywell Residential Technical Support
    1-800-468-1502

20
Product Cross Reference Guide
Forms 63-9575 and 63-9581 information also
found in product installation sheets.
21
www.customer.honeywell.com
  • See Cross Reference Search box in right column

22
The S8910U Advantage
  • When promoting the S8910U keep these advantages
    in mind
  • The S8910U replaces over 100 Honeywell and
    competitors ignition modules reduces inventory
    by stocking one versus many and saves time and
    money looking for the right part.
  • Easy to use instructions and adaptation
    accessories saves the contractor valuable time
    and resources.
  • Personality Plug-Ins - match the ignition
    sequence of the model being replaced using the
    plug in selector tabs for a true Universal
    replacement.
  • The S8910 is application flexible and can be used
    with single rod or dual rod systems, and natural
    or LP gas.
  • The diagnostic LED makes troubleshooting simple,
    identifying ignition lockout, flame rectification
    signal and control failure, solving the problem
    quickly and satisfying the customer.

23
S8910U Universal Electronic Ignition Knowledge
Test
24
Universal Electronic Ignition Knowledge Test
  • Now that you completed this training module, take
    the short quiz to test your knowledge.

25
Test
  • The S8910U1000 is a hot surface ignition module?
    T or F
  • The S8910U is application flexible and works with
    single or dual rod systems? T or F
  • The S8910U can be used with LP gas only? T or F
  • The LED light displays the following normal
    operation, lockout, weak flame signal and
    internal error? T or F
  • If the internal error signal is still present
    after a new call for heat the S8910 can be
    repaired, it does not have to be replaced? T or
    F

26
Test
  • The S8910U has personality plug-ins to match
    the ignition sequence of the control being
    replaced? T or F
  • An ignition sequence must be chosen as there is
    no factory set sequence? T or F
  • The adaptation accessory kit includes parts to
    convert from White Rodgers and Robertshaw
    controls? T or F
  • The Honeywell S8910U replaces over one hundred
    Honeywell and competitive ignition modules? T or
    F
  • The Honeywell S8910U is widely recognized in the
    industry as a top performer in the industry? T or
    F

27
Answer Key
  • T
  • T
  • F
  • T
  • F
  • T
  • F
  • T
  • T
  • T