Why/When is Taguchi Method Appropriate? - PowerPoint PPT Presentation

About This Presentation
Title:

Why/When is Taguchi Method Appropriate?

Description:

all 8 columns assigned. Column 1 to a 2-Level Control Factor and. all other columns to 3-Level Factors (3 s) No need to keep any column empty' ... – PowerPoint PPT presentation

Number of Views:137
Avg rating:3.0/5.0
Slides: 19
Provided by: drpr2
Category:

less

Transcript and Presenter's Notes

Title: Why/When is Taguchi Method Appropriate?


1
Why/When is Taguchi Method Appropriate?
  • A new tip Every Friday

Friday, 20th July 2001
2
Taguchi Method inner L18 array with outer
L4 and L9 NoIsE arrays (next 9 slides)
New Tip 14
Friday, 20th July 2001
3
inner L18 array with outer L4 and L9 NoIsE
arrays
  • all 8 columns assigned
  • ? Column 1 to a 2-Level Control Factor and
  • all other columns to 3-Level Factors
    (3 slides)
  • No need to keep any column empty
  • ? To study interaction between
  • Control Factors A and B
  • assigned to columns 1 and 2
    (3 slides)
  • Column 1,2 assigned
  • ? to a single 6-Level Control Factor
    (3 slides)

4
L18 expt. with 2 Noise Factors (K, M)
(7B) Taguchi Method for QR L18 expt. with 2
noise factors
Measurements to Capture Noise
Control Factors
Expt.No.
A is a 2-level factor
and B-to-H are 3-level factors
5
L18 expt. With L4 Noise Array
Measurements to Capture Noise
(7) Taguchi Method for QR L9 expt. with 2
noise factors
L4 Array

N
Control Factors
M
K
K, M and N are noise factors with 2 level each, 4
combinations as per L4 Array are K1M1N1 ,
K1M2N2, K2M1N2 and K2M2N1
6
L18 expt. With L9 Noise Array
(7) Taguchi Method for QR L9 expt. with 2
noise factors
L9 Array
Control Factors
Measurements to Capture NoIsE
K, M, N and P are noise factors with 3 level
each, 9 combinations as per L9 Array are used
for measurements 1 to 9
7
(7B) Taguchi Method for QR L18 expt. with 2
noise factors
L18 expt. with 2 Noise Factors (K, M)
Measurements to Capture Noise
Control Factors
C
D
E
F
G
H
A x B can be studied
8
L18 expt. With L4 Noise Array
Measurements to Capture Noise
(7) Taguchi Method for QR L9 expt. with 2
noise factors
L4 Array

N
Control Factors
M
K
C
D
E
F
G
H
K, M and N are noise factors with 2 level each, 4
combinations as per L4 Array are K1M1N1 ,
K1M2N2, K2M1N2 and K2M2N1
A x B can be studied
9
L18 expt. With L9 Noise Array
(7) Taguchi Method for QR L9 expt. with 2
noise factors
L9 Array
Control Factors
Measurements to Capture NoIsE
C
D
E
F
G
H
K, M, N and P are noise factors with 3 level
each, 9 combinations as per L9 Array are used
for measurements 1 to 9
A x B can be studied
10
(7B) Taguchi Method for QR L18 expt. with 2
noise factors
L18 expt. with 2 Noise Factors (K, M)
Measurements to Capture Noise
Control Factors
C
D
E
F
G
H
R is entirely a new Control Factor (consuming
columns 1,2 and 3). Even though it may be
constructed out of A and B, Interaction between
AXB can not be studied
11
L18 expt. With L4 Noise Array
Measurements to Capture Noise
(7) Taguchi Method for QR L9 expt. with 2
noise factors
L4 Array

N
Control Factors
M
K
C
D
E
F
G
H
K, M and N are noise factors with 2 level each, 4
combinations as per L4 Array are K1M1N1 ,
K1M2N2, K2M1N2 and K2M2N1
R is a 6-Level Factor
12
L18 expt. With L9 Noise Array
(7) Taguchi Method for QR L9 expt. with 2
noise factors
L9 Array
Control Factors
Measurements to Capture NoIsE
C
D
E
F
G
H
K, M, N and P are noise factors with 3 level
each, 9 combinations as per L9 Array are used for
measurements 1 to 9
R is a 6-Level Factor
13
More Tips Links below
  • Friday, 3rd Aug 2001
  • Friday, 27th July 2001
  • Friday, 20th July 2001
  • Friday, 13th July 2001
  • Taguchi Method
  • 1st Priority Variance Reduction 2nd Priority
    Factor Effects
  • 15. inner L9 array with outer L4 and L9
    NoIsE arrays
  • Taguchi Method
  • inner L18 array with outer L4 and L9 NoIsE
    arrays
  • Taguchi Method Why/When is Taguchi Method not
    Appropriate?

Tips 12, 11, 10 ?
14
More Tips Links below
  • Friday, 6th July 2001
  • Friday, 29th June 2001
  • Friday, 22nd June 2001
  • Taguchi Method
  • inner L8 array with outer L4 and L9 NoIsE
    arrays
  • Taguchi Method
  • Useful at ALL Life-stages of a Process or
    Product
  • Taguchi Method
  • Performs Process centering or fine tuning

Tips 9, 8, 7 ?
15
More Tips Links below
  • Taguchi Method Identifies the right NoIsE
    factor(s) for Tolerance Design
  • Taguchi Method
  • Finds best settings to optimize TWO quality
    characteristics Simultaneously
  • 7. Taguchi Method
  • When to select a Larger OA to perform
    Factorial Experiments
  • Friday, 15th June 2001
  • Friday, 8th June 2001
  • Friday, 1st June 2001

Tips 6, 5, 4 ?
16
More Tips Links below
  • Friday, 25th May 2001
  • Friday, 18th May 2001
  • Friday, 11th May 2001
  • Taguchi Method Using Orthogonal Arrays for
    Generating Balanced Combinations of NoIsE Factors
  • Taguchi Method Signal-to-Noise Ratio for Quality
    Characteristics approaching IDEAL value
  • 4. Taguchi Method improves " quality at
    all the life stages
  • at the design stage itself

Tips 3, 2, 1 ?
17
More Tips Links below
  • Friday, 4th May 2001
  • Friday, 27th April 2001
  • Friday, 6th April 2001
  • 3. Taguchi Method Appropriate for Concurrent
    Engineering
  • 2. Taguchi Method can study Interaction
  • between Noise Factors and Control
    Factors
  • 1. Taguchis Signal-to-Noise Ratios are in Log
    form

18
end
Write a Comment
User Comments (0)