Title: Photovac Discount Structure 2002
1 Voyager Gas Chromatograph Concept
2Voyager Basics
- Truly portable
- Only 15 pounds (6.8kg) with battery installed
- 15.4 (39cm) long x 10.6 (27cm) wide x 5.9
(15cm) high - Multiple Column, Dual Detector Portable GC
- 3 Columns (Heavy, Middle, and Light Compounds)
- PID (Photoionization Detector) and optional ECD
(Electron Capture Detector) - 3 Levels of Instrument Operation
- Factory programmed methods
- User modified methods
- Total VOC quick screen mode
- Intrinsically Safe (Class 1, Division 1, Groups
A,B,C D) - The only portable GC with this classification
3Voyager Basics
- Completely self-contained
- Internal carrier gas cylinder
- Oven
- Battery
- Internal data logger
- On-board data handling provides immediate results
- No laptop needed in field
- Comprehensive Windows software for data download
and reports - Easy to use
- Minimal training required for point press
operation
4Voyager Chromatography
- Carrier Gas
- High Purity Nitrogen or Ultra Zero Air
- Carrier Life 8 hours at 1800 psi
- Carrier Flow Control via Software (Pressure)
- Column Oven
- Isothermal 55oC to 80oC
- Higher temperatures help clean out columns and
avoid contamination - Detector Injection Port Heated to Column
Temperature - Two Sampling Methods
- Variable Volume Sample Loop
- Syringe Injection
5Voyager Chromatography
- Benefits of the 3 column set
- Overlapping selectivities cover
- Heavy compounds (C7 to C12)
- Middle compounds (C3 to C7)
- Light compounds (C1 to C3)
- Simplified method development
- Columns do not degrade
- Vapor phase injections only
- Moderate temperatures with no ramping
6Column Scheme Voyager GC Assay 1
Carrier Gas (N2)
Column A
70
Column B
ECD
30
Pre-Column
Column C
Make-Up Carrier Gas
Precolumn 4m x 0.53mm
x 2.0 um SPB-35 Column A (HEAVY) 8m
x 0.25mm BLANK Fused Silica Column B
(MID-RANGE) 20m x 0.32mm x 1.0 um
Supelcowax10 (PEG) Column C (LIGHT)
15m x 0.32mm x 12 um Quadrex 007-1
7Column Scheme Voyager GC Assay 2 - 7
Column A
Carrier Gas (N2 or UZ Air)
Column B
PID
Precolumn
Column C
Precolumn 2.5m x 0.53mm x
2.0 um SPB-35 Column A (Heavy) 8m x
0.32mm BLANK Fused Silica Column B (Mid-Range)
20m x 0.32mm x 1.5 um Supelcowax 10 (PEG) Column
C (Light) 1.2m x 1.6mm 1 SP1000 on
60/80 Carbopack B
8Voyager Assays
- Target Compounds grouped into Assays (1-7)
- Each Assay includes
- GC Method
- Integration Settings
- Compound Library
- Assay 1 Environmental Assay
- Most comprehensive with 40 compounds
- Assay 2-7 Occupational Health and Safety
- Targeted by industry segment
9Assay 1 Environmental Compound List
- Chloromethane
- Vinyl Chloride
- Bromomethane
- Chloroethane
- Methylene Chloride
- 1,1-Dichloroethylene
- Acetone
- Carbon Disulfide
- Vinyl Acetate
- t-1,2-Dichloroethylene
- Methyl Ethyl Ketone
- c-1,2-Dichloroethylene
- Chloroform
- 1,1,1-Trichloroethane
- 1,1,2-Trichloroethane
- Dibromochloromethane
- Chlorobenzene
- Ethylbenzene
- m-Xylene
- p-Xylene
- o-Xylene
- Styrene
- Bromoform
- 1,1,2,2-Tetrachloroethane
- 1,3-Dichlorobenzene
- 1,4-Dichlorobenzene
- 1,2-Dichlorobenzene
Carbon Tetrachloride Benzene 1,2-Dichloroethane Tr
ichloroethylene 2-Chloroethyl Vinyl
Ether 1,2-Dichloropropane Bromodichloromethane Met
hyl Isobutyl Ketone c-1,3-Dichloropropene Toluene
t-1,3-Dichloropropene 2-Hexanone Tetrachloroethyle
ne
10Assays 2-7 Occupational Health Safety
- Assay 2 Petroleum and Petrochemical
- Methanol
- Ethanol
- MTBE
- TAME
- Benzene
- Toluene
- Ethylbenzene
- m-, o-Xylenes
- Naphthalene
- Assay 6 Surfactant Manufacture
- Ethylene Oxide
- Propylene Oxide
- Assay 4 ABS Rubber
- Acrylonitrile
- 1,3-Butadiene
- Styrene
- Assay 5 Pulp Paper
- Hydrogen Sulfide
- Methyl Mercaptan
- Ethyl Mercaptan
- Dimethyl Sulfide (DMS)
- Dimethyl Disulfide (DMDS)
- Acetone
- Methyl Ethyl Ketone (MEK)
- a-Pinene
- Methanol
- Assay 7 Latex Paint Monomers
- Methyl Acrylate
- Methyl Methacrylate
- Ethyl Acrylate
- n-Butyl Acrylate
- iso-Butyl Acrylate
- Acrylic Acid
- Vinyl Acetate
- Ethylene
- Styrene
11Assay Customization
- Preprogrammed assays can be customized in the
SiteChart software for specific applications - Existing assays are modified by adding or
deleting compounds - Full control of all hardware and software methods
development and calibration parameters - Customized assays are then sent to Voyager from
the PC