Atomic parity violation in ytterbium - PowerPoint PPT Presentation

1 / 28
About This Presentation
Title:

Atomic parity violation in ytterbium

Description:

... induced PBC mirror deterioration in vacuum. Slow drifts. Technical noise (above shot ... Substrates were provided by Rainbow Research Optics, Inc, Denver, CO ... – PowerPoint PPT presentation

Number of Views:62
Avg rating:3.0/5.0
Slides: 29
Provided by: simonmro
Category:

less

Transcript and Presenter's Notes

Title: Atomic parity violation in ytterbium


1
Atomic parity violation in ytterbium
Dmitry Budker University of California,
Berkeley Nuclear Science Division, LBNL
PREX Workshop JLAB, August 16-18, 2008
http//socrates.berkeley.edu/budker/
2
Outline
  • Motivation
  • The Yb system
  • Measurement principle
  • Apparatus
  • Preliminary parity-violation results
  • Experimental issues
  • Outlook (Yb and Dy)

3
Motivation
  • Verification of large predicted atomic PV effect
  • (x100 Cs DeMille, Kozlov et al, Das et al)
  • Isotopic ratios and neutron distributions
    (6 stable isotopes ?N8)
  • Nuclear spin-dependent PV anapole moments
    (valence neutrons)

4
Isotopic ratios and neutron distributions
  • Atomic PV calculation errors cancel in isotopic
    ratios
  • Dzuba, Flambaum, and Khriplovich, Z. Phys. D 1,
    243 (1986)
  • But enhanced sensitivity to the neutron
    distribution rn(r)
  • Fortson, Pang, Wilets, PRL 65, 2857 (1990)
  • Atomic PV ? Neutron distributions
  • For 170Yb-176Yb, QW ? -100
  • ?QW(Standard Model) ? 6
  • ?QW(Neutron Skin) ? 3

5
Isotopic ratios and neutron distributions new
development (ArXiv)
  • Neutron-skin effects in different isotopes are
    correlated

6
Anapole Moments
Ya
. B. Zeldovich, V. G.
Vaks

1959
AM first introduced
V.V. Flambaum, I.B. Khriplovich

1980
-
84
O.P. Sushkov
Nuclear AM detectable in atoms

1995
E.N.Fortson and co-workers
Tl AM small

1997
C. E. Wieman and co-workers
Cs AM detected !
PNC within nucleus ! ?probe of weak meson
couplings
7
Atomic Yb energy levels and transitions
5d6p
PNC amplitude ?10-9ea0 DeMille (1995)
M1?10-4 µB J.E. Stalnaker, et al, PRA 66(3),
31403 (2002)
ß?210-8 ea0/(V/cm) C.J. Bowers et al, PRA 59(5),
3513 (1999) J.E. Stalnaker et al, PRA 73, 043416
(2006)
8
Stark-PV-interference Geometries and
invariants
9
PV effect on line shapeseven isotopes
PV-Stark interference terms
168,170,174,176Yb
or ?
10
PV effect on line shapesodd isotopes
xNSD10-11 ea0 for odd Yb isotopes x10-9 ea0 x
must be measured with 0.1 accuracy
11
The Yb PNC Experiment
Electric and magnetic fields define handedness
12
Optical system and control electronics
Light powers Ar 15W TiSapp (816 nm) 1
W Doubler (408 nm) 50 mW
PBC Confocal design, 25 cm Finesse 10,000
(upgrading to 40000 ??) Locking Pound-Drever-Hal
l technique
13
Typical signal
  • 174Yb resonance split by B?70 G E3 kV/cm
  • Expected PV asymmetry 210-4/ E/(kV/cm)
  • Asymmetric lineshape ? AC Stark effect

14
Atoms in electric field the Stark effector
LoSurdo phenomenon
Johannes Stark (1874-1957) Nazi Fascist
15
Reversals and pseudo-reversals
  • E-field reversal (14 ms 70-Hz modulation)
  • Lineshape scan (200 ms/point x 100 pts/lineshape
    40 s)
  • B-field reversal (every few minutes)
  • Polarization angle (occasionally)
  • E-field magnitude
  • B-field magnitude
  • Angle magnitude

For ???/4?
16
Reversals and pseudo-reversals
17
Statistical Sensitivity
  • With parameters presently achieved, the shot
    noise limit is
  • 10 hrs should correspond to a 0.5 measurement

18
But there are some problems
  • Photo-induced PBC mirror deterioration in vacuum
  • Slow drifts
  • Technical noise (above shot-noise)
  • Stray electric fields ( up to a few V/cm)

19
Power-buildup cavity design and characterization
C. J. Hood, H. J. Kimble, J. Ye. PRA 64, 2001
Ringdown spectroscopy
20
Power-buildup cavity design and
characterization mirrors
Substrates were provided by Rainbow Research
Optics, Inc, Denver, CO
Finesse of 29000 seen with REO mirrors Photodegrad
ation is still a problem Locking electronics
needs work
21
The 70-Hz E-modulation schemeto avoid
low-frequency noise and drift issues
20-s integration
Due to bias ex ? 25 V/cm
Different pattern and polarization dependence
for PV
22
Present status PV results
  • About 14 hours of data collection
  • Limited by shot noise and stray fields ? to be
    improved
  • Systematics checks in progress

23
Present status systematics
Average stray ex-field 150 mV/cm
24
Progress towards measuring PV in Yb
  • Completed Work
  • Lifetime Measurements
  • General Spectroscopy (hyperfine shifts,
    isotope shifts)
  • dc Stark Shift Measurements
  • Stark-Induced Amplitude (ß) 2 independent
    measurements
  • M1 Measurement (Stark-M1 interference)
  • ac Stark shifts measured
  • Almost there
  • Verification of PV enhancement
  • And then
  • PV in odd isotopes NSD PV, Anapole Moments
  • PV in a string of isotopes neutron
    distributions,

25
Yb the team
K. Tsigutkin A. Family
D. Dounas-Frazer post-doc
undergrad new grad.student
J. E. Stalnaker grad. student ? prof. _at_ Oberlin
26
The parity violation experiment in Dy
evolved into
27
Phys. Rev. Lett. 98, 040801 (2007)
28
? PV with mHz sensitivity Status setting up
Write a Comment
User Comments (0)
About PowerShow.com