Firmware Upgrading - PowerPoint PPT Presentation

1 / 7
About This Presentation
Title:

Firmware Upgrading

Description:

Upgrading Firmware ... Firmware (.cbf files) can be downloaded from www. ... Only the same firmware type is allowed to be upgraded, eg Ultra II to Ultra II, ... – PowerPoint PPT presentation

Number of Views:221
Avg rating:3.0/5.0
Slides: 8
Provided by: luyun
Category:

less

Transcript and Presenter's Notes

Title: Firmware Upgrading


1
Firmware Upgrading
  • With UCM05 and Comfigurator

2
Firmware Upgrading
  • Why Upgrade Firmware?
  • To fix bugs
  • To add new features
  • UCM05 is required to upgrade Comfort II Flash
    versions (ie min 5.100). UCM 5.174 min is
    recommended. UCM 5.147 is min version able to
    upgrade UCM, Slaves and MPU01. UCM5.156 able to
    upgrade Comfort
  • Comfort II, Slaves, UCMs can be upgraded for
    firmware gt 5.100

3
Upgrading for Firmware lt 5.100
  • For Comfort II and Slave lt 5.100, use MPU plug in
    to upgrade to Flashable. Once MPU is plugged in,
    it can be upgraded.

4
Upgrading Firmware
  • Connect Programming Cable with 2 ends (6 way and
    2 way) to UCM doing the programming. The other
    end with 6 way is connected to the Module being
    upgraded
  • Shunt PP2 header to enable firmware upgrade

5
Upgrading Firmware
  • UCM to Module to be programmed

6
Upgrading Firmware
  • Upgrading UCMs You need a UCM05 to upgrade a
    UCM05.
  • Upgrading UCMs and Slaves. The module being
    upgraded should not be connected to Comfort
  • Upgrading Comfort. If UCM05 is upgrading its own
    Comfort, after programming cable is connected,
    Comfort does not work, and keypads will start
    beeping. Disconnect siren and keypads if too
    noisy.

7
Upgrading Firmware
  • Firmware (.cbf files) can be downloaded from
    www.comfortforums.com/upgrades.html
  • Comfigurator gt Menu Transfer gt Firmware Upgrade
  • Browse and select the .cbf file
  • Only the same firmware type is allowed to be
    upgraded, eg Ultra II to Ultra II, UCM/CBUS to
    UCM/CBUS etc.
  • Transfer starts and takes 30 seconds to several
    minutes depending on the file. See Progress bar
  • After upgrading is completed, remove programming
    cable, remove PP2 and Reset Comfort
  • If any errors occur during upgrade, repeat the
    process
Write a Comment
User Comments (0)