Components for the calculation of the OCvar for
Combustion (1)
  • Electricity cost ?e ce 103 k/PJ fuel
    input/a
  •   ?e additional electricity demand (new total
    consumption old total consumption) GWh/PJ fuel
    input
  • ce energy price /kWh
  • Sorbent cost ?s cs efunabated ? / 103
    k/PJ fuel input/a
  •   efunabated unabated emission factor of
    pollutant t pollutant/PJ fuel input
  • ?s specific sorbents demand (e.g. NH3) ton/t
    pollutant removed
  • cs sorbents price /ton
  • ? removal efficiency ( 1 -
    efabated/efunabated)
  • Catalyst cost (?cat cicat / ltcat) (103 /
    3,6) k/PJ fuel input/a
  • ?cat catalyst volume (per unit of installed
    capacity) m3/MWth
  • cicat unit costs of catalysts k/m3
  • Ltcat life time of catalyst 103 hrs
  •   Labour cost man-year/MWth (?l cl) 106 /
    (3,6 pf) k/PJ fuel input/a
  • ?l labour demand man-year/MWth
  • cl labour cost/wages k/man-year
  • pf annual operating hours at full load h/a

2
Components for the calculation of the OCvar for
Combustion (2)
  • Waste disposal cost ?d cd efunabated ? /
    103 k/PJ fuel input/a 
  • efunabated unabated emission factor of
    pollutant t pollutant/PJ fuel input
  • ?d demand for waste disposal ton/ t pollutant
    removed
  • cd byproduct/waste disposal cost /ton
  • ? removal efficiency ( 1 - efabated/efunabated
    )
  •  
  • Fuel switch/efficiency improvement k/PJ fuel
    input/a
  • SUM (new consump/prod)i (new price)i SUM
    (old consump/prod)i (old price)i
  • Energy consumption ()
  • Energy production (-)
  • Consumption MJ/GJth input
  • Fuel price /GJ
  •  
  • Cost of low S fuel ?low S clow S 103 k/PJ
    fuel input/a
  • ?low S S difference (Sfuel old - Sfuel new)
    S
  • clow S extra cost of low S fuel /GJ/S
  • Supplementary Cost k/PJ fuel input/a
  • (for cost parameters others than mentioned above,
    e.g. process emissions)

3
Components for the calculation of the OCvar for
Processes (1)
Electricity cost ?e ce 103 k/t/a ?e
additional electricity demand (new total
consumption old total consumption) GWh/t ce
energy price /kWh    Sorbent cost ?s cs
efunabated ? / 103 k/t/a   efunabated
unabated emission factor of pollutant t
pollutant/t ?s specific sorbents demand (e.g.
NH3) ton/t pollutant removed cs sorbents
price /ton ? removal efficiency ( 1 -
efabated/efunabated)    Catalyst cost (?cat
cicat / ltcat) k/t/a   ?cat catalyst volume
(per unit of installed capacity) m3/t cicat
unit costs of catalysts k/m3 ltcat life
time of catalyst 103 hrs    Labour cost (?l
cl / pf) k/t/a   ?l labour demand
man-year/t cl labour cost/wages
k/man-year pf annual operating hours at
full load h/a    
4
Components for the calculation of the OCvar for
Processes (2)
Waste disposal cost ?d cd efunabated ? /
103 k/t/a   efunabated unabated emission
factor of pollutant t pollutant/t ?d demand
for waste disposal ton/ t pollutant removed cd
byproduct/waste disposal cost /ton ?
removal efficiency ( 1 - efabated/efunabated)    
Fuel switch/efficiency improvement k/t/a  SUM
(new consump/prod)i (new price)i SUM (old
consump/prod)i (old price)i Energy
consumption () Energy production
(-) Consumption GJ/t Fuel price
/GJ    Supplementary Cost k/t/a (for cost
parameters others than mentioned above, e.g.
process emissions)  