Title: Data Acquisition Components
1(No Transcript)
2Software Components
Data Acquisition Components
The "Base" software components require neither
technical expertise nor programming, enabling you
to easily setup hardware and start operating your
data acquisition system as soon as possible.
High Added-Value Components
The Add-on software components offer advanced
functions such as customized windows, monitoring
clients, multi-logging, and data acquisition
trigger conditions.
Interface Components
The Gate software components enable data
acquisition using power measuring instruments and
Modbus devices in combination with data
acquisition units. With these components, you
can quickly connect OPC servers and network
cameras.
3Model Codes and Pricing
4Simplifies Installation
- Integrated Installer
- All installers centralized into a single program
- Install only the apps you need, all at once
- Select apps to install, enter serial numbers for
each - To put additional component(s) later, type in
appropriate password(s) to the component(s) you
want to install.
5Model Codes and Pricing for UPGRADING
6DAQLOGGER WX101
- Real-time trend, numerical, meter, and bar graph
display modes - Supports most YOKOGAWA DAQ products
- DAQStation DX, DXA, MV, CX, FX
- DARWIN, MX100, uR recorders
- - Supports up to 32 devices in a single system
- Supports up to 1600 channels and 3 communication
interfaces - Ethernet, RS-232C, RS-422/485
- - 1 sec maximum (fastest) data logging interval
- - Client Server system
7DAQLOGGER Connectivity Image
Support up to 32 devices / 1600ch multi connection
RS-232C/422A Converter
Ethernet
RS-232C
Lantronix Terminal Server With Redirector
RS-422A
RS-232C
8Unique Functions on DAQLOGGER
Event Processor E-Mail (with text data, PNG or
message), FTP data transfer and Data Conversion
are activated by Event detection. File
utility File merge/divide on viewer
software Tag editor Beep Sound for Alarm
Monitoring
9What is Event Processor
This software can send a message by e-mail when
a selected event condition occurs, and attach
predefined files to the message, transfer them
through FTP, or automatically convert them to
ASCII, Excel or Lotus1-2-3 format.
Event Conditions Alarm, Regular time interval,
End of data file creation, End of report file
creation, User event Target files Data file,
Report file, PNG file, User file(text file or
instantaneous values) Actions E-mail transfer,
FTP transfer, File conversion
10What is Event Processor
Example of sending an E-mail with a PNG file of a
monitor screen
11DAQ32 Plus WX102 (for DARWIN)
- - Works with all DARWIN Series
- DAQ32- standard software
- DAQ32Plus- optional software
- - Supports everything from Setup to Data
Processing. - - Supports DARWIN IP setting
- - 500msec/300ch data logging
- - Wide Variety of Display options
12MXLOGGER WX103 (for MX100)
- Software components
- Launcher, Configuration, Monitor, Viewer, Monitor
server - Functions
- - Supports up to 20 MX100 units and up to 1200
channels with single PC system. - - 600ch/100msec, 1200ch/200msec interval data
logging available. - - 3 individual log-intervals in one system
- - Support Math (same as MX100 standard)
- - Manual alarm output via MX100 unit
- - Monitor server function for remote monitoring
with DAQLogger and/or DAQLogger client
13Client/Server with MXLOGGER
Unit1, 10msec
DAQLogger Client
MXLOGGER 10msec/100msec Monitor Server
Unit1, 100msec
Unit2, 100msec
Unit2, 1sec
- Use MXLOGGER and DAQLogger Client
- - Supports up to 960ch as client/server system.
- 960ch60chx16units or 16connections
- - Individual windows for each hardware and
sampling speed. - Data update rate at client PC is same as MXLogger
setting. - - 495.00 195.00/each (up to 16 connections)
14DAQExplorer WX104
- Supporting DAQ devices
- DAQStation DX, MV, CX and FX
- Desktop
- Easy icon operation
- Download, upload data and setup files through
easy operation like clicking, dragging and
dropping icons. - Remote Monitor(16 connections)
- Data monitoring alarm overview on the PC via
network - Configuration
- Data viewer
- File Conversion
- Conversion to ASCII, Lotus1-2-3 or Microsoft
Excel file
15AddObserver WX11
- Add-on software for DAQ32Plus, DAQLOGGER,
DAQEXPLORER - Easy screen design without
requiring specialized knowledge - Creates a
realistic image of the site using background
bitmapped images. - Wealth of picture elements
including trend/level, analog, digital meters and
thermometer
16AddMulti WX12
- Multiple Interval File Data Logging software
running as a simple add-on to existing
DAQ32Plus/DAQLogger software - - 50 measurement groups with 32 channels per
group. - - Each group has individual measurement interval.
- - Each group has individual start/stop conditions
with a wide range of triggers. - - Each group logs to an independent data file of
separate folder on PC. - - Simultaneous multi-group start or single group
start.
17AddMulti Functional Image
Target
DAQs hardware
Measurement Group
Measurement Conditions of each Group
A
Gr.1
Gr.2
B
C
Gr.3
?
?
??????
??????
GR.n
n
18Logging start/end conditions
- A wide range of data acquisition start/end
conditions are provided to each group. - - Start conditions Immediate, Timer, Alarm
Trigger, Level Trigger - - End conditions Continuous, Timer, Alarm
Trigger, Level Trigger, Data Records
19Considerable application of AddMulti
Data monitoring of multiple test chambers
DAQLogger AddMulti
Centralized monitor, Data storage
Remote monitor from QA Manager
Remote monitor from Developing Manager
Chamber
Chamber
Chamber
Chamber
///////////////////
- - Create individual file to each chamber.
- - Each file is created with individual
measurement interval, if required. - Each file can be created only when the chamber
is running. Various start/stop condition setting
allows to collect only the necessary data. - - Centralized monitoring, remote monitoring is
also available.
20Unique application of AddMulti
- When you want to create a long term continuous
data file with a slower measurement interval, and
when you need faster interval for an abnormal
data, AddMulti can provide a solution.
Stored into file A with slower sampling interval
Stored into file B with faster sampling interval
when alarm is detected
The same tag data can be assigned into the
different groups of AddMulti. If the different
intervals are set to the groups, you can get two
individual files created with the different
intervals. If an alarm condition is set to the
group, the data collecting starts just when the
alarm is detected.
21AddTrigger WX13
- Software components
- Launcher, Monitor, Logger, Viewer
- Functions
- - Various trigger
- - Pre-Trigger
- Pre-trigger up to 1800 data
- - Channel level, Alarm, Daily fixed time trigger
- - Auto Conversion
- - Excel/Lotus/ASCII
-
22Gate Series WX1
- Gate Functions
- Gate applications handle the special
communication needs of certain Yokogawa products
ltORgt - They handle special communication protocols
- Gate applications serve this data to other
DAQWORX applications
23Gate Series WX1
- GateOPC
- Functions
- - Get data from OPC servers
- - Supports 16 OPC servers
- - Supports OPC browsing function
- - Fastest log rate is 500ms
24- GateMODBUS
- Functions
- - Gets data from the hardware which support
MODBUS RTU protocol - - Fastest log rate is 500ms
- - Scaling function
- - Supports various data type16bit
integer/unsigned 16bit integer,32bit
integer/unsigned 32bit integer
25- GateDXP
- Functions
- - Gets data from DX100P/DX200P (style4 or later))
via Ethernet or serial - - Supports up to 16 DX100P/DX200P units
- Fastest log rate is 500ms
- GateDXP must be specified when connectivity to a
DX100P/DX200P is required
26- GateMX/MW
- Functions
- - Acquires data from the MW100 or MX100, and
outputs the latest data to connected DAQLOGGER
and Add-on software groups. - - Supports up to 32 MW100 or MX100 units in any
combination - GateMX/MW must be specified when connectivity to
MW100 or MX100 is required
27 Gate MX100 ( Group Connection Mode )
GateMW/MX functional image When used with MX100,
GateMW/MX acquires data on a measurement group
basis, serving the latest data to connected
DAQLOGGER and Add-on software groups.
Max. 10ms
Max. 10ms
Max. 10ms
Max. 10ms
Max. 1sec
Gr.A
Gr.H
Gr.M
Gr.C
Gr.E
Max. 10ms
Max. 10ms
Max. 10ms
Max. 10ms
Max. 10ms
Measurement Groups
Measurement Groups
Measurment Groups
Measurement Groups
28- GateWT
- Functions
- - Gets data from WT(GPIB/RS232C)
- - Output data to DAQLOGGER via DAQWORX data
highway - - Supports 16 WTs max
- - Fastest time interval is 500ms
- Support WT series
- - WT100 series(WT110/110E/130)
- - WT200 series (WT200/210/230)
- - WT1000 series (1010/1030/1030M)
- - WT2000 series (2010/2030)
29- GateEye
- Functions
- - Get image data from network camera
- - Get DX/CX/MV snapshot data
- - Supports 4 DX/CX/MV/network cameras max
- - Fastest time interval is 500ms
- Always AddObserver is required as client software.
Proven compatibility with WEB cameras from AXIS
communications Model AXIS2100(basic model),
AXIS2120(motion detection model) WEB http//www.a
xis.com/us/index.htm Price AXIS2100 274.99 _at_
insight.com to 299.00 _at_ CDW.com AXIS2120
899.99 _at_ insight.com
30Multi Clients
BuilderRun timer Build 15 different screens.
Monitor Server
Run-time Only. 15 AddObserver licenses. Each PC
has a different license and a different screen.
31With LabView
DAQLogger
GateOPC
OPC Server
32High redundancy system
GateOPC
OPC Server
Secure redundancy
DA100 100ch