FULL BUSINESS CASE' THE RELOCATION OF SHETTLESTON CAMPUS - PowerPoint PPT Presentation

1 / 23
About This Presentation
Title:

FULL BUSINESS CASE' THE RELOCATION OF SHETTLESTON CAMPUS

Description:

Cartridge Filter UV. Break Tank. Water Conservation. 100% ... Cartridge Filter UV. Site Environmental Microclimate. Section - materials. Roof mounted ... – PowerPoint PPT presentation

Number of Views:36
Avg rating:3.0/5.0
Slides: 24
Provided by: KenN102
Category:

less

Transcript and Presenter's Notes

Title: FULL BUSINESS CASE' THE RELOCATION OF SHETTLESTON CAMPUS


1
GREATER EAST END BUSINESS CLUB 28 APRIL 2005
JOHN WHEATLEY COLLEGE EAST END CAMPUS
2
Presentation on Haghill/South Carntyne Campus
  • IAN GRAHAM
  • COLLEGE PRINCIPAL

3
Figure 3.2
4
Figure 5.3
5
(No Transcript)
6
Figure 5.7
7
Figure 5.2
8
(No Transcript)
9
(No Transcript)
10
(No Transcript)
11
EW Section
Elevation to Haghill Road
Elevation to Carntyne Road
Section and Elevations
12
(No Transcript)
13
(No Transcript)
14
Sunpath Diagram
Prevailing Winds
Street noise and pollution
The site is very exposed on the South and East
aspects
Site Environmental Microclimate
15
Sunpath Diagram
Prevailing Winds
The site is very exposed on the South and East
aspects
Site Environmental Microclimate
16
  • Double Glazing
  • For South Façade light transmittence of 0.6 or
    less or 1m overhang
  • Low E coating to reduce heat loss
  • Top and bottom opening lights preferable
    (minimum 125mm)
  • Trickle vent to frame
  • High performance seals

Site Environmental Microclimate Section Optimum
Single Sided Ventilation
17
Heat Pumps
  • Uses buried pipe loops to reject heat - no visual
    impact
  • Provides cooling water for ICT rooms
  • Medium capital cost
  • Very low running rosts
  • No distribution of Chilled Water
  • No roof space required - avoids problems with
    water tank
  • Circuit can also be used for heating (heat pump)
  • Gives flexibility to spaces for underfloor
    heating

Ground Loops
Energy and Utilities Ground Source Cooling
18
600
500
Annual Energy Consumption (kWh/m2) Typical
Practice
400
300
200
100
0
Air-Conditioned Building
Naturally Ventilated Building
Annual Energy Consumption Target Setting
19
  • A biomass boiler uses waste material or
    renewable sources e.g. refuse, wood, crops etc to
    generate useful heat
  • Recommendation for a 100 kW heat-only system to
    be developed to meet the year round base load for
    the entire site
  • Any of three options for Biomass fuel are
    viable, namely
  • Short Rotation Coppice (SRC)
  • Miscanthus
  • Woodfuel
  • Woodchip fuel source from off-cuts from the
    forestry commission
  • 100kW biomass boiler 0.35GWh of carbon free
    energy per year for the John Wheatley College

Typical layout of modern biomass fired boiler
Energy and Utilities Alternative Energy Systems
20
Rainwater to Grey Water to Black Water
Rainwater
Break Tank
Break Tank
Urinal
WHB
WC
WHB
WC
WHB
Cartridge Filter UV
Cartridge Filter UV
Solar Powered Pump
Solar Powered Pump
Irrigation
Black Water to Reed Beds
Rainwater Retention Tank
Grey Water Retention Tank
Water Conservation 100 Sustainable
21
Roof mounted solar collectors
Exposed concrete soffits
Good window design
Site Environmental Microclimate Section -
materials
22
Biomass Boiler Plant
  • Wind Science Project
  • Biomass Boiler Unit
  • Ground water cooling for ICT rooms
  • Rainwater and Grey Water Recycling
  • Solar collectors for domestic hot water
  • Photocell bollards to external circulation
    lighting
  • Rainwater and Grey Water Recycling
  • Considerations for Reed bed
  • PIR control of
  • Lighting
  • Security
  • Waste recycling

Solar Energy Solar Collectors
Harnassing wind energy
Energy and Utilities Alternative Energy Systems
23
(No Transcript)