Title: Gordon Stretch
1- Gordon Stretch
- Director Standard Commercial and Residential
Product Engineering
2- Introducing the 90 Efficient A. O. Smith
- Residential Power-VentGas Water Heater
3- With Vertex, A. O. Smith innovation has
revolutionized residential water heater design
and performance!
4- Vertex was developed by A. O. Smith in
conjunction with the U.S. Department of Energy,
to help meet the D.O.E.s goal to provide
American homeowners with a greater choice of
energy-efficient products.
5- Vertex Highlights
- 90 thermal efficiency
- Power-vent
- 76,000 BTU
- 127 gallon first hour delivery
- 92 gallon recovery _at_ 90 rise
- Endless hot water, always delivers one more hot
shower - Recirculating side taps for combination systems
6- The Challenges
- Satisfy any homeowner who needs more hot water
than a standard 40 or 50-gallon heater can
deliver - Increase energy-efficiency to reduce energy costs
- With Vertex, A.O. Smith has provided an
easy-to-install option to meet both challenges!
7Options to meet the challenge
- Install 75-gallon or larger water heater
- Install two 40 or 50-gallon water heaters
together - Install multiple on-demand water heaters
- The A. O. Smith residentialline includes all
these options. Now, theres an easier and better
way!
8- The source of the power and efficiency of theA.
O. Smith Vertex is a fully-submerged internal
coil heat exchanger.
9- A. O. Smith Vertex Heat Exchanger
- Greatly improves heat transfer surface compared
to standard gas flue tube - Helps keep hot combustion gases in the tank
longer to lengthen heat transfer cycle - Allows 76,000 BTU input in a50-gallon tank
10- A. O. Smith Vertex Heat Exchanger
- Harmful sediment is less likelyto build up on
heat exchanger - Inside and outside of heat exchanger, and the
entire Vertex tank, are protectedby A. O.
Smiths exclusive commercial-grade PermaGlas
Ultra Coat lining
11- Because of its 90 thermal efficiency, Vertex is
a fully condensing water heater - Condensate elbow and outlet are supplied for
installation at the heat exchanger outlet at the
bottom of the unit
12- A. O. Smith Vertex is also equipped with separate
hot and cold side taps for - Combination systems providing domestic hot
water, plus - Forced-air space heating, or
- Radiant floor heating
- Any system requiring a recirculating hot water
loop
Hot Out
Cold In
13Vertex
14Compare Vertex First-Hour Delivery to
Conventional Residential Units
15Compare Vertex 90 RiseRecovery to
Conventional Residential Units
16- Vertex will provide all the hot water homeowners
need, without requiringthem to change their
lifestyle! - Lets compare to on-demand water heaters.
17- As the leading providerof hot water
solutions,A. O. Smith offers allthe products
plumbing contractors need andwant, including our
ProStar on-demand line!
18- On-Demand has a niche in the market
- Smaller homes and families
- Room additions
- Point-of-use applications
- New construction projects where on-demand venting
and water/gas line requirements, plus adequate
on-demand sizing can be built into the plan - However
19- A single On-Demand Water Heater delivering 6-8
gpm at 45º rise simply cannot handle a high peak
demand load. - With 127 gallon first hour delivery and 92 GPH
recovery at 90º rise, the A. O. Smith Vertex can
handle the load!
20Compare Vertex Thermal Efficiency to
Conventional Residential Units
With gas prices continuing to rise, Vertex will
heat more water, and reduce a homeowners energy
bills!
21Vertex Installation
- No surprises!
- Vertex delivers revolutionary performance with
contractor or DIY-friendly installation!
22Vertex Installation
- 22" Footprint means Vertex will be an easy fit
for replacement of almost any conventional 40 or
50 gallon water heater
22"
23Vertex Installation
- Standard 3/4" water connectionson 8" centers
24Vertex Installation
- Standard 1/2" gas line sizing into side-mounted
connection to Intelli-Vent Control Valve
25Intelli-Vent Control Valve
- Advanced electronic circuitry for precise
temperature control - Easy touch-pad temperature adjustment
- Advanced diagnostics, with easy-to-understand LED
error codes
26Vertex Installation
- Comes with all PVC pipe and fittings to connect
heat exchanger outlet to blower, including
condensate elbow and outlet
27Power-Vent Installation Versatility
- Vertex uses inexpensive, contractor-friendly PVC
vent pipe, instead of metal B-Vent or Category
III Stainless Steel - Allows vent runs terminating horizontally or
vertically, as follows - 2" pipe up to 25 equivalent feet
- 3" pipe up to 65 equivalent feet
- 4" pipe up to 128 equivalent feet
28Another A. O. Smith Innovation
- Vertex comes with new A. O. Smith Vent
Attenuation Assembly (V.A.A.) for installation
where an extra-quiet operating environment is
essential!
29A. O. Smith V.A.A.
- Can be installed in vertical or horizontal
position within vent run
30- Finally, the best of everything for todays high
demand homes! - Exceptional output
- 90 thermal efficiency
- Easy installation guide DVD available
31For more information on Vertex, visit
www.aosnewproducts.com