Tevatron progress: Aug04 to Feb05 - PowerPoint PPT Presentation

1 / 8
About This Presentation
Title:

Tevatron progress: Aug04 to Feb05

Description:

Tevatron progress: Aug'04 to Feb'05. Luminosity: (average initial peak L) ... MP9 studies of separator sparking 10 times /10kV (Prokofiev) Diagnostics: ... – PowerPoint PPT presentation

Number of Views:34
Avg rating:3.0/5.0
Slides: 9
Provided by: shil3
Category:

less

Transcript and Presenter's Notes

Title: Tevatron progress: Aug04 to Feb05


1
Tevatron progress Aug04 to Feb05
  • Luminosity (average initial peak L)
  • Aug.04 (7 stores 3657-3678)
    L84.4
  • End of Jan (9 stores 3925-3953) L92.9 (10)
  • -6 N_p, 6 N_pbar, (??eff ) reduced -10
  • record L as of Aug.04 103e30 store
    3657
  • record after FY04 shutdown 105.2e30 store
    3952
  • Same lifetimes L 8.1?8.7 hrs, ?eff 16?17 hrs
    N_pbar 25?22hrs, N_p 90hrs
  • Int L is about same (15-18.5 then ?16 pb-1/wk
    now)
  • FY05 goal integral 470 pb-1 (now 100 pb-1)

2
Shutdowns
  • FY04 shutdown 12 weeks, 28 jobs, including
  • SNEG pipes at D0 and CDF LB Q columns BH, McGee
  • 2 separators _at_D17polarity switches RM et al
  • 412 dipoles reshimmed D.Harding
  • 7 um FWs at E11 N.Eddy et al
  • Kaiser coil and roll measmnts JA,
    J.Volk
  • B0 and D0 HLS systems installed J.Volk et al
  • 4 houses warmed up MechSupport
  • Short 3 days shutdown Feb05 15 jobs including
  • F17 kicker magnet replaced Bruce
  • Crystal collimator fixed Dean
  • Vacuum leak A49 fixed Scott

3
Highlights on Operations/Reliability
  • Beam startup took 24 shifts ( as planned)
  • A bit slowed by troubles with vacuum
    valves Dean!
  • Reached pre-shutdown L60e30 after 9 stores
  • Suffered from separator sparks for 12 days in
    Dec04
  • 3 stores lost , 2 damaged
  • lowered voltages by 10 on Dec 18, 2004 ? one
    spark since then
  • Mixed source shots regular ? very long stores
    (record 45.3hrs in 3920)
  • Stores lost due to QFA4, cryo(1), controls(1), RF
    trips (5 trips, 1 lost), longitudinal damper off
    (1)
  • D0 and (less) CDF halo rates are down, LOSTP
    spiky after 20hrs, no motion at 12 Hz
  • Superb lifetimes at 150, ramp losses low
  • Losses in squeeze 1-2 p/pbars, dropped Q 20?8,
    still
  • Scallops were regular, disappeared after dQ
    -0.002 change
  • No transv-dampers at injection ? either higher
    Q or Octupoles
  • CDF and D0 IP positions and angles corrected
    (upto 3mm) with correctors or by alignment of B0
    LB quadrupoles
  • Lifetime at 150 is great, losses on ramp smaller
  • P-lifetime at LB wandering 60hrs?160hrs?60hrs

4
Tevatron Beam Physics Progress
  • Octupoles O1 O2 commisioned for differential
    chromaticity control, OZF OZD for stability at
    150 ? chromaticit reduced as well as losses (esp
    pbar) (Petr, Yuri and Jerry)
  • Longitudinal blowup is multibunch mode 1 (Tan)
  • Lattice re-measured after shutdown at 150 LB
    OK (Valery)
  • WP scan at EoS ? better proton tunes (ZXL, VS,
    JPC)
  • Pbar bunch-by-bunch orbits at 150 as modeled
    (Sasha Valishev)
  • Tev B-Beam Phenomena paper in progress (many)
  • Wake field effects seen in head-tail motion
    (Vahid)
  • Beam-beam modeling ? Q0 and 23 RFC idea
    (Velery, Sasha Valishev)
  • Theory of b-b resonance diffusion with noise
    (Yuri)
  • P-loss rate analysis at HEP and 150 Na/emma2at
    (VS)
  • IBS emittance growth study, 2100 hrs lifetime
    (Vladimir, Alvin)
  • Analysis of losses of pbars from RR and AA
    (Aimin, Tanaji)
  • MP9 studies of separator sparking ? 10 times
    /10kV (Prokofiev)

5
Diagnostics
  • Abort gap monitor operational (Randy, Eugene)
  • New BPMs at A3 and B3, see pbars, TBT (SW, JS,
    BW, et al), finish in April05
  • Noisy MUX removed? better 1.7GHz spectra
    (Andreas, Ralph)
  • 7 um FWs _at_E11 acceptable for CDFD0 (Nathan Eddy)
  • SBD reports dP/P and long-Emittance (Bob Flora)
  • First results from long phase detector (Aisha,
    BW, JPC)
  • BBQ shows 60 Hz lines here and there (Tan)
  • HLS systems at B0 works (Jim Volk)
  • 90 of p-SLite found, nice modeling, progress
    toward more believable data (Randy)
  • Q from 21MHz Schottky under test (TSen, Paul)
  • IPM electronics to be ready at the end of March
    (AJ et al)

6
Misc
  • MTF measurement mini-review 0.7 unit b1 drift,
    broken anchors not a problem (Pierre B. et al)
  • BBCompensation review OKd FY05 plan (VS, ZXL,
    et al)
  • CDF/D0 lumi ratio still unresolved, D0 admitted
    errors (Vaia et al)
  • BTeV cancelled
  • 6 invited speakers for PAC05 from Tevatron
  • Personnel Out Aimin Xiao ? AID
  • Claudio Rivetta
  • Vinay Boocha
  • Sasha Valishev
  • Kip Bishofberger (Mar)

  • In Jean-Paul Carneiro (Jan)
  • Elmie Peoples (Jan)
  • Seva Kamerdzhiev (end of March)
  • Eliana Wendt (mid March)
  • Sasha Valishev (April)
  • Alex Koschik (offer sent)
  • Part-timers MM ? Run II Upgr, TS?LARP
    (TanAndreas active)
  • Letter of recognition to Mike McGee

7
Next Steps
  • Increase Np 230?250?280 (same Emm) ? 1020 in L
    Tev coord
  • Lifetime improvements at HEP ?
    6-12 in ?L
  • Octupoles_at_HEP to reduce chromas Petr/Yuri
  • Stabilize pbar tunes in stores Ron
  • Explore new proton WPs 7/12 lt Q lt 3/5
    Jerry et al
  • Reduce ? 35? 28 cm ? 8-12 in
    L Sasha/Val
  • Reduce p-loss at 150 helix (octupoles, tunes) ?
    2-4 in L coord
  • Fly only E11 Wires at 150 to save 1 pi ? 1-2 in
    L Nathan
  • Other items
  • Finish BPM installation and Commissioning (BPM
    project team)
  • Pbar SL mirror move in/out (Randy, Stephen, Todd)
  • Commission tune-tracker (CYTan)
  • Commission head-tail monitor and orbit
    stabilization (Vahid Ranjbar)
  • Test magnets, assemble and test TEL-2 (BBC team)
  • Install IPMs and OTRs (Andreas, Vic et al)
  • Minor SBD improvements, and FWs OAC with AT dP/P
    (Flora et al)
  • Commission Long Phase Monitor (Aisha, Jean-Paul)
  • Replace RF cavity water-heaters (JohnReid)
  • Make B0 D0 HLS systems operational (Jim Volk)

8
Next Three Months Expectations
  • Over the next 3 months, I expect
  • stable operation at 90-100 e30, combined shots
  • D0 luminosity monitor fixed (?6 in AVG lumi)
  • less study time as reliability improves
  • possible improvements
  • 10-20 increase in proton intensity with same
    emittance
  • 5-10 more pbars from RR ? smaller Emm, 120mA
    stash
  • 5-10 lumi-lifetime improvements? WPs, octupoles,
    etc
  • ? 35? 28 cm studies to start and may be even
    cashed in
  • As the result, I expect peak CDF luminosity to be
    around 120-130e30 by May 1, 2004
Write a Comment
User Comments (0)
About PowerShow.com