Luminosity Monitoring For PrimEx - PowerPoint PPT Presentation

About This Presentation
Title:

Luminosity Monitoring For PrimEx

Description:

You don't quantify this effect and do not include in final error' ... HYCAL collimation of TAC 0.25 (worst case, no photon collimator) ... – PowerPoint PPT presentation

Number of Views:22
Avg rating:3.0/5.0
Slides: 12
Provided by: jlab5
Learn more at: https://www.jlab.org
Category:

less

Transcript and Presenter's Notes

Title: Luminosity Monitoring For PrimEx


1
Luminosity Monitoring For PrimEx
  • Dan Dale
  • PrimEx Collaboration Meeting
  • February 23, 2007

2
E.P. point 14
  • Electron counting systematics listed as 0.8.
    How did you get this number?

Electron Counting Systematics
0.8 discrepancy between CLOCK and OUT-OF-TIME
methods
3
E.P. point 15
  • You discuss in the Appendix effects of beam
    intensity instabilities on rate sampling. You
    dont quantify this effect and do not include in
    final error

0.8 discrepancy between CLOCK and OUT-OF-TIME
methods CLOCK trigger sampling used -gt
insensitive to beam instabilities
4
Point 11Clock frequency, window width
  • Ne ne / (W x ntrigs) Live1
  • Clock frequency 195.3125 -0.020 kHz
  • W 7 microseconds
  • integral linearity lt 25 ppm
  • differential linearity 100 psec

5
DS point Different PS dipole settings--run 4339
collimator 0.1 off
6
Effect of Collimator Position on Tagging Ratios
7
Effect of Collimator Position on Tagging Ratios
units are inches
8
TAC losses
0.1 interact in vacuum window Helium
overwhelmingly pair production
9
Point 13 Section 25 all numbers in two tables
identical except last one. Something is not right
  • Luminosity Error Budget
  • ________________________________________
  • effect error()
  • Uncorrected leakage current 0.5 (1.4/3)
  • TAC statistics 0.2 (0.5 per T channel)
  • Electron counting systematics 0.8 (clock versus
    out of time)
  • Electron counting statistics negligible
  • TAC reproducibility 0.4
  • HYCAL collimation of TAC 0.25 (worst case, no
    photon collimator)
  • Beam position/collimator effect 0.2
  • Absorption in TAC runs not yet evaluated
  • __________________________________________________
    _____________
  • 1.1

10
What we can ultimately do.
  • Luminosity Error Budget
  • ________________________________________
  • effect error()
  • Corrected leakage current 0.3 (1.4/3/2)
  • TAC statistics 0.2 (0.5 per T channel)
  • electron counting systematics 0.8 (clock versus
    out of time)
  • Electron counting statistics negligible
  • TAC reproducibility 0.4
  • HYCAL collimation of TAC 0.25 (worst case, no
    photon collimator)
  • Beam position/collimator effect 0.2
  • Absorption in TAC runs not yet evaluated
  • __________________________________________________
    _____________
  • 1.0

11
  • Points 1,3 Please define meaning of T-counter
    and T channel
  • Point 2, 16 In section 4 (2002 run analysis)
    just T counters used. E-T coincides since
    implemented. Needs to be written up.
  • Point 5 absolute efficiency of TAC
  • dedicated run????
Write a Comment