Title: TrueSTEAM
1TrueSTEAM Humidification Systems
- Module 3 Basic Installation
2Module 3 Basic Installation
- Definition of a basic Installation
- Whats included in the TrueSTEAM box
- Step by step Installation Instructions
- Cautionary measures for avoiding common
installation mistakes - What homeowners can expectafter a TrueSTEAM
installation
3Whats Included in the TrueSTEAM Box?
4Tools and Parts Needed
- Tools needed to install TrueSTEAM
- Wire cutter/stripper
- Torx driver T-20 and T-30
- Standard screwdriver
- 1-3/4-in. diameter hole saw
- 1/8-in. drill bit
- 18-gauge wire (up to 5 conductor)
- Other Optional Parts
- Condensate pump rating of 212F (100C) if used.
- Drip pan with water sensor shut-off required
underneath TrueSTEAM if installed in or above
finished space.
5Tips and Precautions
- Be sure to read and understand the Installation
Guide and complete list of precautions before
starting work! - Adhere to voltage, heavy equipment and hot water
warnings in the manual - Comply to all install, plumbing, wiring
guidelines in the manual, as well as those listed
in your local guidelines - Wear safety glasses
- Do not install in locations which are
- Outside operating temperature range 34F to
104F - In confined space (less than 1 foot of clearance)
- Exposed to outside weather
DEDICATED TRUESTEAM HOTLINE 800-814-9452
6Step 1 Choosing a Location
- Choose a location that has access to a
- Vertical surface with adequate clearances.
- Cold water supply line must be used.
- Drain with a high-temperature water rating.
- Electrical circuit rated to your humidifier.
Required Minimum Circuit Capacity
HM506 7 Amps HM509 10
Amps HM512 12 Amps
Model
7Step 2 Mounting on the Supply Duct
- Position template on supply duct, and ensure
proper - clearances from A-coil.
8Step 3 Mount Bracket
- Secure bracket to duct using provided
self-drilling sheet - metal screws.
9Step 4 Insert Duct Nozzle
- Install duct nozzle by ensuring o-ring gasket is
properly - seated in the groove, and slide foam gasket
down over - nozzle.
- Insert nozzle and twist clockwise to ensure
tight seal of - nozzle to TrueSTEAM.
10Step 5 Mounting TrueSTEAM
- Push down to secure humidifier to bracket arms.
- Ensure gasket forms tight seal in duct hole.
- Allow 4 inches clearance from
- nozzle outlet to any duct wall
- and allow 24 inches of
- downstream open duct
- air space to prevent duct
- condensation.
11Step 6 Plumbing
Use only cold water. Do not use hot water
supply. a. Water Filter. Insert 1/4-inch copper
or plastic water line. Apply modest pull to
ensure a tight fit. b. Back-flow preventer
valve. Insert 1/4-in. copper or plastic water
line. Apply modest pull to ensure a tight fit.
c. Connect 1/2-in. drain tube. Secure drain tube
to barbed fitting with hose clamp. d. Shut off
the water supply. Secure 1/4-in. copper or
plastic water feed tube.
12Step 6 Plumbing
13After Installation
- Educate the homeowner on what to expect next.
- It may take up to a week of continuous operation
to achieve the humidity control set point. - A slight plastic smell may be detectable the
first week of operation. This is normal and will
dissipate after running a short time. - There may be a slight increase in the homeowners
energy bill even when TrueSTEAM is sized and
operating correctly. Set the expectation that
comfort costs money to avoid callbacks.
14Support Materials
- Additional Materials on TrueSTEAM Installation
are available. - Visit www.forwardthinking.honeywell.com
- Click on Humidification
- Enter literature form 69-2285 TrueSTEAM
Installation Manual
15Module 3 Basic Installation
- Definition of a basic Installation
- Whats included in the TrueSTEAM box
- Step by step Installation Instructions
- Cautionary measures for avoiding common
installation mistakes - What homeowners can expectafter a TrueSTEAM
installation.