Title: Recycler VME Damper Update


1
Recycler VME Damper Update
  • Systems-Instrumentation-SDA Meeting
  • 2/6/08

2
Event on 1/06/08
3
Timing in the FPGA
4
Install New VME Crate on 1/15/08
  • Replace Horizontal 8 slot Tracewell with Vertical
    21 slot Dawn crate
  • Better cooling
  • Bigger power supply
  • Horizontal Board did not come up with new crate
    installed
  • Found FPGA dead
  • Replaced Horizontal Board with Spare
  • No firmware change
  • No glitches observed for 1 week

5
Install Firmware Update on 1/23/08
  • Add more data latches around arithmatic
    operations to improve timing stability
  • Add more diagnostic peak detectors kick alarms
    on both systems
  • Fixed onboard diagnostic buffers
  • Record Inputs (A-B), Intensity(AB), Kick data
  • Capture 7 turns at 212MHz