Title: Nuclear Power Regulatory Overview
1Nuclear Power Regulatory Overview
- The Keys To Our Success
- By
- Bob Wills RRPT
- GEL Laboratories, LLC
2Key Objectives
- REMP-RETS 10 CFR 61 Activities
- NRC ODCM REG Guides NUREG-BTPs
- Isotopes of Concern (How Hard To Look)
- QA/QC Regulatory Requirements
- Review Rad-Waste BTP REMP BTP
- MARLAP
3What Factors Drive QA/QC in US Nuclear Facilities?
4Key Elements Outlined In Title 10 CFR 61
- Classification of waste for near surface disposal
- Considerations given to long lived radionuclides
and their shorter lived precursors (Parent to
Daughter) - Consideration must be given to the concentration
of the radionuclide - Consideration must be given to the physics form
of the radionuclide (Normal or Special Form)
5Key Isotopes For Waste ClassificationAs Noted In
10 CFR 61.55
- C-14
- Ni-59
- Nb-94
- Tc-99
- I-129
- Pu-241
- Cm-242
- Alpha emitting nuclides with T1/2 greater than 5yr
- All nuclides with T1/2 less than 5yr
- H-3
- C0-60
- Ni-63
- Sr-90
- Cs-137
6NRC NUREG 6239
- Radioanalytical technology for 10 CFR 61 selected
radionuclides - Analytical methods for C-14, Co-60,Ni-63/59,
Tc-99, Sr-90, Nb-94, I-129, Cs-137 - Additional isotopes
- Be-7/10, Al-26, Cl-36, Mo-93,
- Cd-109/113m, Sn 121m/126
7How low do you need to gofor 10 CFR 61 isotopes?
- Limits as noted in the BTP page 5 are 0.01 times
the value as noted in Table 1 or Table 2 - GELs administrative limits are 1000 times lower
than the required limits - Lets review the values in BTP page 5...
8Analytical Requirements in the ODCM
- Within the ODCM you have license requirements for
analytical testing - The Environmental Monitoring section lists
requirements for interlaboratory comparison
programs - This may apply to 10 CFR 61 programs
- Would this be a good work practice for INPO?
9Key Isotopes for REMP
- Gross Alpha / Beta (Air Samples)
- Tritium (Ground and Drinking Water)
- Co-60 (Ground and Drinking Water / Food)
- Cs-137(Ground and Drinking Water/ Food)
- I-131 (Milk and Air Samples)
- Ni-63 (Ground and Drinking Water)
- Fe-55 (Ground and Drinking Water)
- Sr-89 90 (Ground and Drinking Water
10How low do you need to go for REMP analysis?
- All LLDs (MDC) listed are a-priori or prior to
the count (page 40 NUREG-1301) guidance for ODCM - Limits as noted in the REMP BTP NUREG-1301 page
64 Table 3.12-2 - All programs are driving MDCs well below the
required limits - Many plants are requesting Tritium at 150 pCi/L
11Need a Break?
12NRC Regulatory Guides NUREGs
13NRC Regulatory Guide 4.15
- Records Track and Control of Samples, Instrument
Data (Backgrounds, Calibration Data etc.) - Radionuclide Reference Standards used for
Calibration (NIST traceable) - Performance checks required with control charts
- Corrective action program to review conditions
that fall outside the predetermined control value
144.15 Guide Continued
- Alpha and gamma detectors energy calibration
- Energy resolution checks for spectrometry systems
- Quality control samples
- Intralaboratory Analysis (Duplicates), LCS,
Method Blank - Data Review and Computational Checks
- Audits of laboratory systems
15MARLAP
- Overview of MARLAP Volume I, II, III
16MARLAP Table Of Contents Review
- Volume 1 section 3.0 Sample Matrix Planning
- Volume 1 section 8.0 Data VV / Quality Control
Samples etc. - Volume II section 12.0 Laboratory Sample Prep.
- Volume II section 15.0 Quantification of
Radionuclides - Volume II section 16 Data Acquisition, Reduction
and Reporting - Volume II section 18 Laboratory QC
17Questions?
18Ni-63 Beta Spectrum
19Tc-99m Beta/Gamma Spectrum
20Tc-99 Beta Spectrum
21Fe-55/Fe-59 Beta Spectrum