Airfield Design Criteria - PowerPoint PPT Presentation

1 / 5
About This Presentation
Title:

Airfield Design Criteria

Description:

... ends of the Graded Area of the Clear Zone must be frangible (see Attachment 14) ... constructed to be frangible, low impact resistant structures, or semi-frangible ... – PowerPoint PPT presentation

Number of Views:56
Avg rating:3.0/5.0
Slides: 6
Provided by: airfie
Category:

less

Transcript and Presenter's Notes

Title: Airfield Design Criteria


1
Airfield Design Criteria
Zones are on the ground surfaces are in the air
Primary Surface 1,000 E/S of CL Extends 200
into overruns
Graded Area 1K x 2K
Graded Area 1K x 2K
Primary Surface The elevation of any point on
the primary surface is the same as the elevation
of the nearest point on the RWY C/L.
Lateral Clearance Zone Must be clear of fixed or
mobile objects. (1) Fixed obstacles include
manmade or natural features such as buildings,
trees, rocks, terrain irregularities and any
other features constituting possible hazards to
moving aircraft. Navigational aids and
meteorological equipment will be sited within
these clearances where essential for their proper
functioning. For Army and Air Force, this area to
be clear of all obstacles except for the
permissible deviations noted in Attachment
14. (2) Mobile obstacles include parked
aircraft, parked and moving vehicles, railroad
cars, and similar equipment. Taxiing aircraft,
emergency vehicles, and authorized maintenance
vehicles are exempt from this restriction.
Graded Area Cleared and grubbed of stumps and
free of abrupt surface irregularities, ditches,
and ponding areas. No aboveground structures (see
note 3), objects, or roadways are permitted in
the area to be graded, but gentle swales,
subsurface drainage, covered culverts and
underground structures are permissible. The
transition from the graded area to the remainder
of the clear zone is to be as gradual as
feasible. No part of either area must penetrate
the approach/departure clearance surface. For
policy regarding permissible facilities,
geographical features, and land use in the
remainder of the clear zone, refer to guidance
furnished by each individual Service, and DoD Air
Installations Compatible Use Zone (AICUZ)
guidelines for Clear Zones and Accident Potential
Zones
Frangibility Zone All items sited within this
area to the ends of the Graded Area of the Clear
Zone must be frangible (see Attachment 14). Items
located beyond the Graded Area of the Clear Zone
must be constructed to be frangible, low impact
resistant structures, or semi-frangible
2
Approach/Departure Zones
3,000
3
500
25,000
Clear Zone
APZ I
APZ II
9,000
2,000
3,000
5,000
7,000
500
4
(No Transcript)
5
500
25,000
Clear Zone
APZ I
9,000
APZ II
2,000
3,000
5,000
7,000
500
Write a Comment
User Comments (0)
About PowerShow.com