Title: Report from Florence
1Report from Florence
Mirko Brianzi 20 April 2004
2Bonding Setup in Florence
There is a new Pull Tester in our system, now we
are finally able to make good pull test.
Delvotec 6400
3Status
- Since March bonded 22 new modules (6 chips).
- For this L12p modules the loop height is very
important, so it took a lot of time to set all
the loop parameters and solve some problem. - Now a new program for Delvotec is ready and it
automatically bonds all the front side of the
module, making all the loop shapes more
reproducible (as much as possible). - The failure rate for these modules has been
3fail/module because they are the first ones and
we had to fix some problem, actually the last
ones hadnt any fail.
4PA moving
- The main reason of failure is the PA not glued at
the edge and this make often fail someone of the
last bonds.
Solution
Making some pull test on bad bonds we can say
that anyway too weak bonds are well visible.
Insert of teflon
5Gold pad moving
- Similar problem bonding Bias to Filter Pad
because the bond position is outside the Jig.
bonds
Lateral View
silicon
carrier
support
end of jig
6Dirt
- Sometimes bonding pads on PA are dirty and this
has caused some fail.
7PA gap
Very difficult to reproduce exactly the same loop
height because the mechanical assembly of the
module influence the bond loop.
- For example
- PA-Si gap can vary between 100µm and 220µm.
100
302 000 200 35 277
220
302 000 200 35 278
8Vacuum
- Because the mechanical difference between each
module, sometimes the vacuum flex the silicon
during bonding
so the central bonds can result 50µm higher (or
more).
9Readout bonds
340
240
- Loop heights are as much as possible (within the
specifications).
Specifications min. 200µm max. 350µm?
10Bias bonds
- Bonds in this module are too high but they have
been corrected to 250µm.
370
Specifications min. 200µm max. 350µm?
11Filter bonds
- Its very difficult to stay inside the
specifications.
525
420
In case that some bond is too low, we could
accept it if its above a safe limit (350µm?).
3kV/mm (dry air) 500Vgt170µm
Specifications min. 500µm max. 600µm
12Pull Test on PA
- Results of Pull Test on test bonds on PA
- for 8 modules
Mean force 9.6g Standard deviations 0.22 -
0.37g Abs. minimum value 8.4g
13Pull Test on Readout bonds
- Results of Pull Test on Readout bonds
- for 5 modules
Mean force 11.1g Standard deviations 0.69
0.99g Abs. minimum value 9.0g
( Correction Factor 1.4 )
14Pull test correction
- Measured geometry of bonds used for pull test to
define the correction factor.
Angles can vary depending on the exact point
where the wire is pulled 25-27 for PA test
bonds gt factor 1 16-20 for readout bonds gt
factor 1.4
Factors 161.81 181.62 201.46 251.18 271
.10 301.00
These factors seems very high
15Pinholes after bonding
- Found after bonding
- 2 pinholes not present
- in the Database.
- 1 of them is probably caused by a fail during
bonding.
The correspondent bond have been removed in
this case do we have to update the Bonding
Database?
16Conclusion
- New bonding program for Delvotec include also the
automatic pattern recognition and it is fast and
efficient (using some trick to avoid failure on
PA). - No problems with Data Base, it has been updated
to the last version. - Good and uniform pull test results.