Title: Design Studies of an X-band Multi-beam Klystron


1
Design Studies of an X-band Multi-beam Klystron
  • S. Fukuda
  • KEK

2
Motivation to develop x-band MBK
  • X-band compact linac are desired for the medical
    use and non-destructive inspection ex.
    Cyber-knife machine, handy X-ray inspection for
    chemical plant.
  • We have developed the compact linac of 900keV
    collaborating between KEK and Tokyo university.
    RF source was a commercial magnetron.
  • It is desired to develop a mbk for the next
    stage.
  • If we are succeeded in obtaining the competitive
    budget, we want to develop an X-band mbk.

3
Achieving goal of MBK design
  • Lower applied voltage not to use the insulation
    oil or to use a small insulation oil cup.
  • Output Power (1) Output power of 2 MW.
  • (2) Output power of a10 MW or more.
  • Two approach
  • (1) usual multi-gun assemblies for MBK and
  • (2) magnetic compression gun for MBK (more high
    power version).
  • Designs were performed by Russians of BINP Dr.
    Vladimir Teryaev and Dr. Alexsander Larionov at
    KEK .

4
Project and Parameters (1)
  • Required parameters
  • Vbeam 50kV
  • Prf out 2MW
  • P rf in lt 50W
  • Loading of the cathode should be no more than
    7A/cm2

5
Parameters (2)
6
Sketch of whole MBK
7
Gun Simulation
Bz2.5kG, Bz/Bb2
Focusing by 2-lenses compensation of transverse
Field, less than 0.005Bz Magnetic field is a
key point.
Micro-perv. of a beam-let1.25 Current of a
beam-let14A
8
Cavity simulation
TM410 Mode is used. 6 cavities system
9
Electromagnet Design
10
Klystron simulation one dimensional and Magic
simulation
11
Design Difficulties and Drawback
  • Hot dimension of the cathode
  • Different expansion factors between copper and
    iron for magnetic lens
  • High perveance of 10 microperv. can lead the
    instability, and beam tester is required.
  • Collector is also possible source of instability
    and model test is required.
  • Drawback low efficiency of 40 due to a high
    microperv of a beam-let.

12
More high power version Larionovs
approachMagnetically compression for MBK
More larger cathodes are possibly used. (
more beam intensity) Number of the cathodes
(i.e. beamlets) are possibly used.
13
(No Transcript)
14
10.3MW
10.1MW
9.8MW
15
Summary
  • X-band mbk is desired for an application of a
    compact linac such as medical use and
    non-destructive inspection use.
  • Design attempts of X-band mbk in KEK are shown.
  • Features of low applied voltage to the klystron
    around 50-60kV are achieving goal of these
    designs.