Title: Lecture 21 Bar Development
1Lecture 21 - Bar Development
- October 18, 2002
- CVEN 444
2Lecture Goals
3Bar Cutoff Points
Why do you want to put in cut off points?
Economy!
4Bar Cutoff Points
Factors Affecting Bar Cut-off Points
5Bar Cutoff Points
Factors Affecting Bar Cut-off Points
6Bar Cut of Points
Factors Affecting Bar Cut-off Points
7Determining Locations of Flexural Cutoffs
Given a simply supported beam with a distributed
load.
8Determining Locations of Flexural Cutoffs
Note Total bar length Fully effective length
Development length
9Determining Locations of Flexural Cutoffs
ACI 12.10.3 All longitudinal tension bars must
extend a min. distance d (effective depth of
the member) or 12 db (usually larger) past the
theoretical cutoff for flexure (Handles
uncertainties in loads, design approximations,etc.
.)
10Determining Locations of Flexural Cutoffs
Development of flexural reinforcement in a
typical continuous beam. ACI 318R-95
11Bar Cutoffs - General Procedure
Determine theoretical flexural cutoff points for
envelope of bending moment diagram. Extract the
bars to satisfy detailing rules (from ACI Section
7.13, 12.1, 12.10, 12.11 and 12.12) Design extra
stirrups for points where bars are cutoff in zone
of flexural tension (ACI 12.10.5)
1. 2. 3.
12Bar Cutoffs - General Rules
All Bars Rule 1. Rule 2.
Bars must extend the longer of d or 12db past the
flexural cutoff points except at supports or the
ends of cantilevers (ACI 12.11.1)
Bars must extend at least ld from the point of
maximum bar stress or from the flexural cutoff
points of adjacent bars (ACI 12.10.2 12.10.4 and
12.12.2)
13Bar Cutoffs - General Rules
Positive Moment Bars Rule 3.
- Structural Integrity
- Simple Supports At least one-third of the
positive moment reinforcement must be extend 6
in. into the supports (ACI 12.11.1). - Continuous interior beams with closed stirrups.
At least one-fourth of the positive moment
reinforcement must extend 6 in. into the support
(ACI 12.11.1 and 7.13.2.3)
14Bar Cutoffs - General Rules
Positive Moment Bars Rule 3.
- Structural Integrity
- Continuous interior beams without closed
stirrups. At least one-fourth of the positive
moment reinforcement must be continuous or shall
be spliced near the support with a class A
tension splice and at non-continuous supports be
terminated with a standard hook. (ACI 7.13.2.3).
15Bar Cutoffs - General Rules
Positive Moment Bars Rule 3.
- Structural Integrity
- Continuous perimeter beams. At least one-fourth
of the positive moment reinforcement required at
midspan shall be made continuous around the
perimeter of the building and must be enclosed
within closed stirrups or stirrups with 135
degree hooks around top bars. The required
continuity of reinforcement may be provided by
splicing the bottom reinforcement at or near the
support with class A tension splices (ACI
7.13.2.2).
16Bar Cutoffs - General Rules
Positive Moment Bars Rule 3.
- Structural Integrity
- Beams forming part of a frame that is the primary
lateral load resisting system for the building.
This reinforcement must be anchored to develop
the specified yield strength, fy, at the face of
the support (ACI 12.11.2)
17Bar Cutoffs - General Rules
Positive Moment Bars Rule 4.
- Stirrups
- At the positive moment point of inflection and at
simple supports, the positive moment
reinforcement must be satisfy the following
equation for ACI 12.11.3. An increase of 30 in
value of Mn / Vu shall be permitted when the ends
of reinforcement are confined by compressive
reaction (generally true for simply supports).
18Bar Cutoffs - General Rules
Positive Moment Bars Rule 4.
19Bar Cutoffs - General Rules
Negative Moment Bars Rule 5.
- Negative moment reinforcement must be anchored
into or through supporting columns or members
(ACI Sec. 12.12.1).
20Bar Cutoffs - General Rules
Negative Moment Bars Rule 6.
- Structural Integrity
- Interior beams. At least one-third of the
negative moment reinforcement must be extended by
the greatest of d, 12 db or ( ln / 16 ) past the
negative moment point of inflection (ACI Sec.
12.12.3).
21Bar Cutoffs - General Rules
Negative Moment Bars Rule 6.
- Structural Integrity
- Perimeter beams. In addition to satisfying rule
6a, one-sixth of the negative reinforcement
required at the support must be made continuous
at mid-span. This can be achieved by means of a
class A tension splice at mid-span (ACI
7.13.2.2).
22Moment Resistance Diagrams
Moment capacity of a beam is a function of its
depth, d, width, b, and area of steel, As. It is
common practice to cut off the steel bars where
they are no longer needed to resist the flexural
stresses. As in continuous beams positive moment
steel bars may be bent up usually at 45o, to
provide tensile reinforcement for the negative
moments over the support.
23Moment Resistance Diagrams
The nominal moment capacity of an
under-reinforced concrete beam is To determine
the position of the cutoff or bent point the
moment diagram due to external loading is drawn.
24Moment Resistance Diagrams
The ultimate moment resistance of one bar, Mnb
is The intersection of the moment resistance
lines with the external bending moment diagram
indicates the theoretical points where each bar
can be terminated.
25Moment Resistance Diagrams
Given a beam with the 4 8 bars and fc3 ksi and
fy50 ksi and d 20 in.
26Moment Resistance Diagrams
The moment resistance of one bar is
27Moment Resistance Diagrams
The ultimate moment resistance is 2480 k-in. The
moment diagram is drawn to scale on the basis A
bar can be terminated at a, two bars at b and
three bars at c. These are the theoretical
termination of the bars.
28Moment Resistance Diagrams
It is necessary to develop part of the strength
of the bar by bond. The ACI Code specifies that
every bar should be continued at least a distance
d, or 12db , which ever is greater, beyond the
theoretical points a, b, and c. Section 12.11.1
specify that 1/3 of positive moment reinforcement
must be continuous.
29Moment Resistance Diagrams
Two bars must extend into the support and moment
resistance diagram Mur must enclose the external
bending moment diagram.
30Example Cutoff
For the simply supported beam with b10 in. d
17.5 in., fy40 ksi and fc3 ksi with 4 8 bars.
Show where the reinforcing bars can be
terminated.
31Example Cutoff
Determine the moment capacity of the bars.
32Example Cutoff
The minimum distance is
33Example Cutoff
The minimum amount of bars are As/3 or two bars
34Example Cutoff
Determine the location of the bar intersections
of moments.
35Example Cutoff
Determine the location of the bar intersections
of moments.
36Example Cutoff
The resulting moment-resistance diagram is
37Bar Splices
38Tension Lap Splices
39Types of Splices
40Types of Splices
Class B Spice
(ACI 12.15.2)
All tension lay splices not meeting requirements
of Class A Splices
41Tension Lap Splice (ACI 12.15)
where As (reqd) determined for bending ld
development length for bars (not allowed
to use excess reinforcement modification
factor) ld must be greater than or
equal to 12 in.
42Tension Lap Splice (ACI 12.15)
Lap Spices shall not be used for bars larger than
No. 11. (ACI 12.14.2) Lap Spices should be placed
in away from regions of high tensile stresses
-locate near points of inflection (ACI 12.15.1)
43Compression Lap Splice (ACI 12.16)
44Compression Lap Splice (ACI 12.16)
45Example Splice Tension
46Example Splice Tension
For 8 bars, db 1.0 in and a b g l 1.0
47Example Splice Tension
The As(provided) /As(required) gt 2, class A
splice applies therefore lst 1.0 ld gt12 in.,
so lst 43 in. gt 12 in. The bars spliced are
less than half the number
The As(provided) /As(required) lt 2, class B
splice applies therefore lst 1.3 ld gt12 in.,
so lst 1.3(42.4 in.) 55.2 in. use 56 in. gt 12
in..
Class B splice applies and lst 56 in. gt 12 in.
48Example Splice Compression
Calculate the lap splice length for a 10
compression bar in tied column when fc 5 ksi and
when a) fy 60 ksi and b) fy 80 ksi
49Example Splice Compression
For 10 bars, db 1.27 in.
Check ls gt 0.005 db fy 38.1 in. So ls 39 in.
50Example Splice Compression
For 10 bars, db 1.27 in. The ld 23 in.
Check ls gt (0.0009 fy 24) db
(0.0009(80000)-24)(1.27in.) 61 in. So use ls
61 in.
51Homework
Problem 10.3 Problem 10.4