Title: SAMPLE SLIDES OF THE 2-DAY SEMINAR FOR ENGINEERS
1SAMPLE SLIDES OF THE 2-DAY SEMINAR FOR ENGINEERS
As you will notice there are few words on these
slides, your trainer will provide you with his
experience which will make these images come
alive providing you with the opportunity to
reflect and ask questions, the more the
better. All of the presentation slides are
available in a binder supplied with the seminar.
2PUMP SYSTEM ANALYSIS
3A BRIEF HISTORY OF PUMPS
4A BRIEF HISTORY France 1600S
5 HYDROSTATIC PRESSURE VS. FLUID COLUMN HEIGHT
The weight of a fluid column is
Pressure (p) is equal to the weight of the fluid
(F) divided by the surface area (A) at the bottom
of the fluid column
6PRESSURE VS. THE SHAPE OF CONTAINERS
7OPEN SYSTEMS AND ENTHALPY
Conservation of energy demands that
8PUMP TOTAL HEAD
The energy balance is
The specific energy or head balance is
Subsituting other expressions for head terms
9THE CONTROL VOLUME APPLIED TO A REAL SYSTEM
10PRESSURE HEAD ANYWHERE ON THE SUCTION SIDE OF THE
PUMP
0
11NET POSITIVE SUCTION HEAD AVAILABLE (N.P.S.H.)
DEFINITION NPSH is the head at the pump suction
minus the vapor pressure head
What is vapor pressure ?
12N.P.S.H. REQUIRED
13HOW IS THE N.P.S.H. REQUIRED LEVEL DETERMINED?Â
14SPECIFIC SPEEDÂ
Example
15NPSH REQUIRED CURVES
16OPTIMAL SELECTION OF THE IMPELLER DIAMETER AND
PUMP
17SYSTEM CURVE
18Why increase the impeller diameter when the flow
must be increased?
19MEASURING TOTAL HEAD
20SOURCES OF INFORMATION ON MOTOR EFFICIENCIES
DATA BASE - MotoMaster Department of Energy USA
(DOE)
21Opportunities with higher return
Opportunities in electrical energy reduction Possible decrease in electrical consumption 1 Winning conditions
1. Replace a standard motor with a high efficiency motor Replace a standard efficiency motor with one that meets or surpasses the NEMA Premium standard Typically 1.5 to 5 and as much as 8 When the motors are defective or at the end of their useful life or when a motor must be replaced to accommodate a VFD.
22High efficiency motors
23Opportunities with higher return
Opportunities in electrical energy reduction Possible decrease in electrical consumption 1 Winning conditions
2. Install a variable frequency drive (VFD) A VFD can adjust the speed of a motor in response to a variable demand avoiding the throttling of control valves or the opening of recirculation control valves and the energy losses incurred. Typically 12 to 15 and as much as 27 Ideal solution when the flow varies between 40 and 60
246
PUMP SYSTEMS
25Pumps in parallel - Instability
26Minimum submergence of the pump inlet
27The effect of air (or gas) entrainment in the
pump suction
28VARIOUS ITEMS Quick guide Viscosity ASME max.
pressure allowable
29 DYNAMIC VISCOSITY
30THE EFFECT OF VISCOSITY ON PUMP PERFORMANCE