23D/4D Ultrason
- 2D 2 boyutlu
- 3D 3 boyutlu
- 4D 3 boyutlu canli (zamanli) real-time goruntu
34D Ultrason
- 2D ultrason gebelik tetkikinde kullanilan belki
de en onemli metottur - 3D/4D ultrasonun yayginlasmasi, gebelik
takibinde gerekli olup olmadiginin tartismasini
yaratmistir - 3D/4D ultrason, bilhassa 2D ile yapilan tetkikte
tespit edilmis bazi anomalilerin daha iyi analiz
edilmesinde faydali oldugu gorulmustur - Fetal vucutta protruzyon yapan anomalilerin
tetkikinde onemlidir- noral tup defekti,
omfalosel, gastroskisis - Cardiac
- American Institute of Ultrasound in medicine.
Acoustic output measurement standards for
diagnostic ultrasound equipment. Laurel (MD)
AIUM 1998 - .
44D Ultrason
- Ultrasonun guvenilirligi uzun zamandan beri
bilinmektedir - Insan calismalarinda yan etki gorulmemistir
- Bazi hayvan deneylerinde yani etki gorulmusse de
bu calismalar baskalari tarafindan
tekrarlandiginda ayni sonuclar elde edilmemistir - Bilhassa 3D/4D ultrasonda termal endeks ve de
mekanik endeks otomatik olarak kontrol edilmekte,
ultrason muayenesi sirasinda dokuya yayilan
enerji miktari minimumda tutulmaktadir - Stark CR et al. Short and long term risks after
exposure to diagnostic ultrasound in utero.
Obstet Gynecol 1984 63 194-200
53D/4D Ultrason
- 3D popularitesi artmakta
- iU22 (Phillips), Prosound Alfa-10 (Aloka),
Voluson 730 Expert (GE) - Ortalama muayene suresi 21 dakika
- 2D mean termal indeks (TI) - 0.28, mekanik indeks
(MI) 1.12 - 3D mean TI - 0.27, MI 0.89
- 4D mean TI - 0.24
- 3D/4D muayenesi 2.5 dakika ek
- Akustik seviye, enerji seviyesi yaklasik ayni
- Sheiner E et al. A comparison between acoustic
output indices in 2D and 3D/4D ultrasound in
obstetrics. Ultrasound Obstet Gynecol 2007, 29
(3) 326-8
62D/3D/4D Ultrason
- 2D ultrason ve fetal fizyolojik cevap
- 100 hasta
- 18-24 gebelik haftasi,
- Fetal kalp atis hizi
- AF dikey olcumu
- Umbilical arter Doppler
- Muayene suresi
- Amniyotik sivi da azalma- Istatistiki fark ()
- Fetal kalp hizinda artis- Istatistiki fark (-)
- Doppler, sure- Istatistiki fark (-)
- Akut fetal hemodinamik degisiklikler
- Ural SH, Repke J et al. Does 2nd trimester
ultrasound effect normal fetal physiology. - Oral Presentation, International Society of
Ultrasound in Obstetrics and Gynecology - Chicago, USA, Agustos 2008
7 How Useful Is 3D and 4D Ultrasound in Perinatal
Medicine
- 3D/4D hakkinda tip literaturunde su ana kadar
yayinlanmis 575 makale/calisma var, 438 tanesi
sirf 3D/4D hakkinda - Yuz anomalileri
- Noral tup defektleri
- Iskelet anomalileri
- Konjenital kalp defektleri
- Intrakraniyel anomaliler
- Davranis
- Kurjak A et al. How useful is d and 4D
ultrasound in perinatal medicine. J Perinat Med
2007, 35 (1) 10-27
83D/4D Ultrason
- 3472 fetal anatomik tarama, 2D ve 3D
- 906 tanesinde 1-5 anomali
- 2D ile karsilastirildiginda 3D - multiplanar
tomografik inceleme - 70 daha avantajli
- Defektin ciddiyetinin ve de normalitenin
degerlendirilmesinde 2Dden daha mi iyi
93D/4D Ultrason
- 99 fetus, once 3D/4D, sonrasinda 2D
- 2D 54 fetus normal, 45 fetusta 82 anomali
- 2D ve 3D/4D arasinda anomali tanisinda anlasma
orani 90, intraclass correlation coefficient,
0.834 95 CI, 0.774-0.879 - 3D/4D 2Dden 6 eksik anomali teshis etmis
- VSD (2)
- IVC blokaji
- Tetralogy of Fallot
- Bobrek
- Cystic adenmatoid malformasyon
- Dogum sonrasi tani ile karsilastirma,
sensitivite/spesifisite - 2D 96 - 73
- 3D/4D 92 - 76
- Istatistiki olarak ciddi fark yok
10(No Transcript)
113D/4D Ultrason
- 13-34 gebelik haftalarinda
- 3D/4D ile kalp fonksyon tesbiti
- Tomografik real-time 3D
- Sistolik/diyastolik, atriyal/ventrikuler
hemodinamik tesbit - Anatomik anomali gorulmese de kalp anomalilerine
bagli degisiklikler - Hata T et al. 4D ultrasound in spatiotemporal
image correlation for fetal heart visualization.
J Clin Ultrasound Mayis 2008364204-7.
12(No Transcript)
13(No Transcript)
143D/4D Ultrason
- The effects on maternal anxiety of 2D vs. plus
3D/4D ultrasound in pregnancies at risk of fetal
abnormalities A randomized study - 4D ultrason uygulanan annelerin 80i, 2D ile
karsilastirildiginda, bebegin normal oldugunun
daha inandirici oldugunu - Fakat anksiyetenin istatistiki olarak daha dusuk
olmadigi
153D/4D Ultrason
- 2D ve 3D/4D ultrason kullanildiginda annenin
bebegine psikolojik bagi - Yayinlanmis bazi calismalarda bu bagin ultrasonla
guclendigi, ve de uzun vadede anne ve bebegin
daha az hastaliga yakalanmasina sebep olabilecegi
varsayilmistir - 3D/4D ultrason daha mi etkili
- Penn State Universitesinde calisma
- Rados C. FDA cautions against ultrasound keepsake
images. FDA Consum 2004 38 (1) 12-6
16Ultrasound Research Symposium
- Nisan, 2010
- Philadelphia
- Best Research Prize
17Does Ultrasound Influence the Bond between Mother
and Fetus? Serdar Ural, MD, and MFM Team Penn
State University, College of Medicine
Figures
- Results
- The data from the entire study population (Group
A, 100 patients) was analyzed based on 21
questions while the data of 35 patients (Group B)
was analyzed based on 25 questions. - Group A and Group B both resulted in a p value
lt.0001 indicating that the difference in MFA
scores before and after the ultrasound is
statistically significant. - Questions 22-25, assessing prenatal care, were
analyzed individually. Question 23 was
statistically significant with a p value of
.0156. - Conclusions
- The ultrasound experience is one of many major
events that occur during pregnancy. It becomes a
lasting memory, especially if it is the first
pregnancy. - This study determined that 2D ultrasound
significantly increases the bond between mother
and fetus in addition to 3D and 4D imaging. - The fact that ultrasound has such a profound
impact on the thoughts of mothers suggests that
it can be a stepping stone to incorporate other
aspects of prenatal care into the appointment. - Confounding variables multiple ultrasound
technicians and less than ideal results of
anatomical survey. - Future research fathers reaction to ultrasound
experience, the effect of other patients having
an ultrasound on the MFA, the use of ultrasound
to prevent maternal use of alcohol and tobacco.
- Introduction
- Maternal-fetal attachment (MFA) is a new concept
that encompasses the behaviors mothers evoke
toward their babies. - A handful of studies have been conducted to
determine if fetal ultrasounds are a means for
increasing or even inducing a mothers attachment
towards her unborn child. - Many studies have compared the effects of 3D and
4D ultrasounds on MFA, however, few have
investigated the influence of the basic 2D
ultrasound, considering it is the most common
type of scan used in practice. - It is hypothesized that the ultrasound experience
will have a positive impact on a mothers
feelings for her fetus by increasing her
attachment to the fetus. - Methods
- 100 women obtaining a routine ultrasound scan at
the Department of Maternal-Fetal Medicine at
Hershey Medical Center were recruited. - The 25-question survey given before and after the
ultrasound was based on the MFA questionnaire
developed by Cranley with additional statements
addressing prenatal care. - Group A (64 patients) completed a 21-question
survey. Group B (35 patients) completed a
25-question survey, which included 4 questions on
prenatal care. - The difference between the pre-ultrasound mean
and post-ultrasound mean was analyzed by a
nonparametric 1-sample Wilcoxon signed ranks test.
Table 1 Analysis of Group A maternal-fetal
attachment scores (Q1-Q21)
Observations 100
Mean 0.130
Std Deviation 0.182
Wilcoxon Signed Rank Statistic 1469.5
p value lt.0001
Table 2 Analysis of Group B maternal-fetal
attachment scores (Q1-Q25)
Observations 35
Mean 0.181
Std Deviation 0.208
Wilcoxon Signed Rank Statistic 198
p value lt.0001
Table 3 Analysis of prenatal care questions 22-25
Wilcoxon Statistic p value
Question 22 3 0.25
Question 23 14 0.0156
Question 24 1.5 0.5
Question 25 -1 1.0
184D Ultrason
- Prenatal invaziv tani ve tedavisi icin 4D, 93
fetus - Amniosentez, amnioinfuzyon, CVS, kordosentez
- Prosedur mean 5 dakika, 100 basari
- Oligohidramniyoz, ince plasenta, ince kord
- Zaman, komplikasyon riski daha dusuk
- Kim S et al. 4D ultrasound guidance of prenatal
invasive procedures. Ultrasound Obstet Gynecol
2005, 26 (6) 663-5
19Maternal Obezite ve Fetal Anomali Taramasi2D
- Fetal anatomy ultrasound screening
- American Institute of Ultrasound in Medicine
(AIUM) - Over 25 structures
- 18-22 weeks of gestation
- Variable sensitivity
- 34-60
- Decreases with increased BMI
- Absence of markers, 80 reduction in Down
syndrome risk - Experience
- Standardization
20Obezite2D
- Significant ultrasound impairment
- Visualization decreases
- Mostly cardiac and spine others
- Suboptimal visualization
- Obezite 17
21Maternal Obezite ve Fetal Anomali Taramasi3D/4D
- 18-24 hafta
- 11,000 vaka
- Body mass index (BMI) gt25
- BMI gt25, gt30, gt40
- Sensitivite 66dan 49, 25lere inmis
- 3D/4D yarari?
- Dashe et al. Obstetrics/Gynecology, Mayis, 2009.
223D/4D Ultrason
- 4D 3 boyutlu canli (zamanli) real-time goruntu
- 4D tomografik ultrason incelemesi
- Hacim olcumu icin ideal
- Operatif prosedurlerde daha guvenilir
- Hasta/fetuse yan etki kaniti yok
- 3D/4D yayinlanmis calisma sayisi az
- 2D 3D/4D su anda en faydali yontem
- Tek basina 3D/4D muayene icin yeterli veri yok
234D Ultrason Davranis
- Bugune kadar yapilan deney ve calismalarda fetal
davranis bicimlerinin ultrason ile incelenmesi
sonucu fetal saglik hakkinda bilgi verip
veremeyecegi yonundedir - Bu calismalarda fetal davranis dendiginde el kol
hareketlerinden tutun yuz ifade degisikligine
kadar bircok hareket edebilen bolge ele
alinmaktadir - Fetal davranis incelenmesinin en iyi bilineni ve
standart yontemi olan biyofizik profildir (BPP) - Burda el, kol, govde gibi hareket edebilen
bolgelerin incelenmesi sonucu evet fetus
saglikli, ya da hayir fetus saglikli degil,
dogurmak gerekir gibi sonuclara ulasmaktayiz
24BPP
- Fetal hareket 2
- Fetal tonus 2
- Solunum 2
- Amniyotik sivi 2
- NST 2
- Toplam 10/10
254D Ultrason Davranis
- 14 hareket 4D ile incelenebilir
- Goz kapagi
- Agiz
- Dil
- Dudak bukme
- Gulumseme
- Somurtma
- Esneme
- Elin basa
- Elin yuze (goz, kulak, agiz)
- Bas antefleksyon/retrofleksyon
- Emme
- Yutkunma
264D Ultrason Davranis
- Neonatal donemdeki yuz ifadeleri incelendiginde
fetal surecte 4D ile gorulenlerle ayni oldugu
tespit edilmis - Dogum sonrasi streste olan bebegin yuz
ifadeleri, fetal donemde streste olan bebegin
ifadeleriyle benzerlik gostermekte - Fetal noral gelisim hakkinda bilgi vermekte
- Santral sinir sisteminin gelisimi direk olarak bu
davranislara yansir - Spesifik hareket duzeni (SMP) mevcuttur
274D Ultrason Davranis
- Fetal davranisin dinamik analizi, santral sinir
sisteminin maturasyonu ve gelismesi ile direk
baglantilidir - Norolojik hastaliklarin erken teshisi
284D Ultrason Davranis
- Cok az data
- Arastirma ve dergi yayin kalitesi?
- Standart olusturmak icin cok erken
- Tekrarlanabilir sonuclar gormek sart
- Ornegin BPP
- Yani konumuz cok yeni ve henuz gelismekte olup
literaturde temsili az
294D Ultrason
- Yani fetal davranis sadece tibbi bilgi vermekle
kalmayip psikolojik ve emosyonel yani da var
304D Ultrason Davranis
- Intrauterin gelisme geriligi (IUGR) oldugu
bilinen fetuslerde fetal yuz ifadesi ve de
vucut hareket kalitesinde degisikler oldugu
tespit edilmis - Bu da acaba beyin gelisiminde aksakliktan oturu
olabilecegi teorisini gelistirmis - Yani IUGR olan fetuslerde oksijenlenme aksakligi
beyni etkileyip indirek yolla fetal davranisi da
etkileyebilmektemidir? - Bu da bize davranissal tanida yardimci olabilirmi
sorusunu sordurtmaktadir
31Fetal Behaviour of IUGR Fetuses by 4D USG
- Fetal yuz ifadesi, vucut hareket kalitesi
- Beyin gelisiminde aksaklik?
- 50 IUGR, 50 kontrol
- Hareket duzeni tamamen farkli, hareketlerde
farklilik - IUGR azalmis hareket, sayi, bicim, duzen
- Elin basa hareketi
- Elin yuze hareketi
- Bas retrofleksyon
- Andonotopo W et al. The assessment of fetal
behaviour of growth restricted fetuses by 4D
ultraound. J Perinatol Med 2006, 34 (6)471-8
324D Ultrason Davranis
- Anensefalik fetuste motor hareketlerde
anormallikler - IUGRda benzer hareket degisiklikleri
33Fetal Behaviour of IUGR Fetuses by 4D
- Dogum oncesi bilgi icin
- Iyi fizyolojik bilgi
- 4D 3Dnin canli gosterimidir, 2Dye gore daha
iyi? - Standart henuz yok
344D Ultrason Davranis
- Eger tedavisi olan bir risk ise bilhassa
biyofizik profil ile davranissal degisiklikler
takip edilerek fetuste duzelme olup olmadigi
gorulebilir - Fakat bunun standart olarak kullanilmasi henuz
erkendir - Daha fazlaca sayida kaliteli yayin gerekmektedir
- Cok merkezli calismalara acilen ihtiyac vardir
- Bu sayede fetal norodavranis ve cocuk gelisimsel
sonuclari normativ data elde edilerek,
aralarindaki prediktebilite teyit edilmelidir
353D/4D Ultrason
- 4D 3 boyutlu canli (zamanli) real-time goruntu
- 4D tomografik ultrason incelemesi
- Hacim olcumu icin ideal
- Operatif prosedurlerde daha guvenilir
- Hasta/fetuse yan etki kaniti yok
- 3D/4D yayinlanmis calisma sayisi az
- 2D 3D/4D su anda en faydali yontem
- Tek basina 3D/4D muayene icin yeterli veri yok
36Sonuc
- 2D 3D/4D rutin kullanilmasi gebelikte en
faydali yaklasim - Guvenilir, yan etki yok
- Anne-bebek bagi ve anne anksiyete
- 3D/4D belli anomalilerin incelenmesinde daha
faydali - Yumusak doku, protuzyon, kalp
37Sonuc
- 4Dden elde edilen tomografik goruntuler
bilgisayar araciligiyle anatomik
reconstructiondan gecip 2D ve 3Dye gore
organlar/olcumler daha net goruntu verecek - 4D muayenesi hasta icin cok kisalacak
- Anomali ve de normal teshislerin dogruluk orani
100e yaklasacak
38Referans
- American Institute of Ultrasound in medicine.
Acoustic output measurement standards for
diagnostic ultrasound equipment. Laurel (MD)
AIUM 1998 - Stark CR et al. Short and long term risks after
exposure to diagnostic ultrasound in utero.
Obstet Gynecol 1984 63 194-200 - Rados C. FDA cautions against ultrasound keepsake
images. FDA Consum 2004 38 (1) 12-6 - Martin J et al. Births final data for 2002. Natl
Vital Stat rep 2003, 52 (10)1-113 - Long G et al. A comparative study of routine vs.
selecyive fetal anomaly scanning. J Med Screen
1998 5 6-10 - Ewigman B et al. Effect of prenatal ultrasound
screening on perinatal outcome. RADIUS study
froup. N Engl J Med 1993 329 821-7 - Kurjak A et al. How useful is d and 4D
ultrasound in perinatal medicine. J Perinat Med
2007, 35 (1) 10-27 - Sheiner E et al. A comparison between acoustic
output indices in 2D and 3D/4D ultrasound in
obstetrics. Ultrasound Obstet Gynecol 2007, 29
(3) 326-8 - Goncalves L et al. What does 2 dimensional
imaging add to 3D/4D obstetric ultrsound. J
Ultrasound Med 2006, 25 (6) 691-9 - Kim S et al. 4D ultrasound guidance of prenatal
invasive procedures. Ultrasound Obstet Gynecol
2005, 26 (6) 663-5 - Leung et al. The effects on maternal anxiety of
2D vs. plus 3D/4D ultrasound in pregnancies at
risk of fetal abnormalities A randomized study.
Ultrasound Obstet Gynecol 2006, 28 (3) 249-54
39(No Transcript)