Nessun titolo diapositiva - PowerPoint PPT Presentation

About This Presentation
Title:

Nessun titolo diapositiva

Description:

High frequency, constant potential technology with ripple lower than 2%. ... This value is at the highest levels in the market. ... – PowerPoint PPT presentation

Number of Views:34
Avg rating:3.0/5.0
Slides: 18
Provided by: fabio70
Category:

less

Transcript and Presenter's Notes

Title: Nessun titolo diapositiva


1
(No Transcript)
2
Completely new
  • Endos DC has been designed from scratch.
  • Every component of the system is completely new
  • new generator
  • new tubehead
  • new arm
  • new timer

3
New generator
  • High frequency, constant potential technology
    with ripple lower than 2.
  • Inverter operating at 100kHz frequency. This
    value is at the highest levels in the market.
  • The two features above help in giving the maximum
    energy efficiency ant to keep the patient dose as
    small as possible.

4
New generator
  • Duty cycle 115, adaptive.After a 200ms
    exposure, you just have to wait 3.2 seconds for
    the next exposure. The adaptive duty cycle,
    automatically sets the waiting time according to
    loading conditions.
  • Exposure parameters 65kV, 4/5 mA
  • with DLC technology

5
New generator
  • The choice of a single high voltage (65kV)
    optimizes the range of visible gray levels by
    operating in the optimal dynamic range of digital
    detectors and films
  • This value gives the best representation of all
    the interesting anatomic structures.

6
DLC Technology
  • DLC Dual Low Current
  • It is possible to select two anodic current
    values 4 or 5 mA.
  • The two mA values and the 65kV high voltage have
    been studied to give the best results with
    digital sensors and high speed films
  • Those values allow to operate with highly stable
    and repeatable times (not too short, thus
    unstable not too long, thus subject to patient
    movement)

7
Energetic efficiency
  • Endos DC has been designed to make the best use
    of the electric energy taken from the mains
  • Endos DC is already compliant to the forthcoming
    IEC standards on the reduction of the mains
    harmonics which will be in force starting from
    2004

8
New Tubehead
  • Compact design
  • 0.7mm focal spot
  • weight 4.5 kg
  • new design
  • accessories
  • 30cm cone
  • 35x45mm collimator

9
New arm
10
New timer
  • Selection of 4 receptors
  • Standard film (5mA)
  • High speed film (5mA)
  • Digital (4mA)
  • Programmable (4 or 5mA)
  • The selection of the receptor optimizes
  • Current (4 or 5 mA)
  • Exposure times (depending also on the selected
    tooth)

11
New timer
Anodic current 4/5mA indication
30cm cone indication
X-ray on indication
Manual time selection
Ready indication
Patient size selection
Anatomic tooth selection
X-ray pushbutton
Receptor selection
12
New timer
  • A control on the keyboard, with a signal lamp,
    can be used to automatically increase the
    exposure times when the 30cm extension cone is in
    use
  • Display brightness adjustment
  • Automatic compensation of mains fluctuations
  • Exposure times from 0.01 to 2 s

13
Remote timer
  • Gives complete control over the system from
    outside the examination room.
  • The same keyboard installed on the local timer
    can be removed and installed outside the room by
    means of a simple adapter kit

14
Remote Timer
  • Connection is made with a simple telephone-type
    connector
  • Its possible to convert a local system into a
    remote system at any time by using an adaptation
    kit

15
Connectivity
  • Endos DC incorporates a RS232 serial interface
    which will allow in the future to communicate
    with external devices and perform service
    functions

16
Configurations
  • Mounting options
  • standard wall mount with 30, 60, 80cm extension
    arms
  • wall mount with remote timer keyboard
  • Mobile

Wall mounted units can be installed using two
(single stud) or three fixation holes. Two holes
out of three are compatible with Explor-X 70
holes.
17
Service
  • Average installation time 4 hours, 1 technician
  • Tubehead replacement
  • 1 hour, one technician
  • Minimum adjustments required
Write a Comment