Title: Kein Folientitel
1CyberAir ...the new world of close control air
conditioning
2CyberAir - Product Line
- One complete product line
- 5 unit sizes
- 8 cooling systems
- All cooling systems available in downflow and
upflow - All cooling systems available in all unit sizes
- 2 DX-Versions Standard and Low Noise/Energy
- new controller philosophy
- latest fan technology as standard
38 cooling systems
- A Direct expansion - air cooled
- G Direct expansion - water cooled
- GE1 Direct expansion - water cooled AND
freecooling (Standard version) - GE2 Direct expansion - water cooled AND
freecooling (Low Noise/Energy version) - CW Chilled water
- ACW Dualfluid - Direct expansion - aircooled
and chilled water - GCW Dualfluid - Direct expansion - watercooled
and chilled water - CW2 Dual chilled water
4All cooling capacities in 5 unit sizes
Size1 Size 2 Size 3
Size 4 Size 5
1000
1400
1750
2150
2550
17,5 20 25
30 35
43 51
70 85
61 70
22
28 34
44 48
85 101
101 115
30 39
54 68
74 90
121 146
79
26
49
63
103
A,G,GE,ACW,GCW 1 circuit
A,G,GE,ACW,GCW 2 circuits
CW
CW2
5Standard and Low Noise/Energy
Size 1 Size 2
Size 3 Size 4
Standard ASD/U
24 kW
35 kW
51 kW
79 kW
Increased footprint per cooling capacity
gt reduced power consumption reduced noise level
Size 2 Size 3
Size 4 Size 5
LowNoise/Energy ALD/U
24 kW
35 kW
51 kW
79 kW
6Standard and Low Noise/Energy
Standard ASD 521 A
Footprint 1,56 m² tot abs power 11,0 3,1
kW Noise level 56 dBA COP 4,64 EER 3,62
Size 3
51,0kW
Footprint 0,35 m² tot abs power - 1,8
kW Noise level - 7 dBA COP 0,19 EER 0,71
LowNoise/Energy ALD 521 A
Footprint 1,91 m² tot abs power 11,0 1,3
kW Noise level 49 dBA COP 4,85 EER 4,33
gt savings 1577 /year _at_ 0,1 /kWh
Size 4
53,3kW
7EC fan technology
Standard Motor
EC Motor
8GE1, GE2 - Energy saving systems
GE1 with Standard Version ASD/U only
GE2 with LowNoise/Energy Version ALD/U only
- 3-way cooling water valve
- 3-way GE-valve
- requires external pump
- Small internal speed controlled cooling water
pump - Small internal speed controlled chilled water
pump - no valves
- Zero internal water pressure drop
9Consistent developmentof modular design
- Installation of up to 31 units in one room
controlled via one C7000 System - Combine units with different loads
- Configure number of stand-by units
10CyberAir with C7000
- Decentralised Intelligence on C7000 (I/O
controller) - Unit Sequencing up to 31 units without add boards
as standard - Interfacing on board such as Modbus/SDC/KP
- Different communication levels according to
customer requirement - without Display C7000
- with small display C7000 Plus
- with graphic display C7000 Advanced
11Options
- Electric reheat, up to 21kW, up to 3 steps,
on/off or proportional control - Hot water reheat
- Refrigerant reheat
- Steam Humidification, 3 sizes, proportional
controlled - Raised floor stands
- Ducts, dampers, flexible duct connections
- Ducts with bag type filters or sound attenuators
- Double skin doors and panels
- Capacity control by hot gas bypass or capacity
control valve - special voltages
- .....any many more.....
12CyberAir ...facts and benefits
13Complete Product Range- the perfect solution for
every requirement
- Facts
- All systems are available in Downflow and Upflow
air direction - A complete line in Standard and LowNoise/Energy
version - Standard dual chilled water CW/CW units
- Full range dualfluid units ACW and GCW
- 8 cooling systems in all unit sizes
- Largest single compressor units up to 85kW
- Advanced indirect free cooling GE2
- Benefits
- What every you need, with CyberAir youll get it
14EC fan technology
Benefits
Facts
- High efficiency / Low power consumption
- Energy savings up to 30 compared to standard
fans Reduced operating costs - Increased net cooling capacity
- Scalable air volume setting via C7000
- Easy adaption to changing local conditions
- Additional energy savings
- Reduced noise levels
- Direct drive technology, no belt
- Long and maintenance-free operation
- No abraison, no need for aditional filtration
- Antivibration fan mounting
- Vibration free, silent running AC unit
15EC fan technology
-28
-20
-10
16Integrated Sound Absorbtion
- Facts
- Absorption instead of reflection
- Silent operation through flowoptimised fan design
- Intelligent, silent air ducting
- up to 5dBA less than double skin panels
- Benefits
- Less noise emission to the room
- No need for expensive external noise reduction
measures
17Optimised air path
- Facts
- Smooth air path
- Maximised surface for DX/CW coils
- Enlarged surface and depth for return air filter
- Compressors isolated from the air path
- Benefits
- Reduced internal pressure drop Energy savings
18Consistent development of modularity
Flexibility
- Facts
- Stand alone intelligence of the control system
- Installation of up to 31 units per room
controlled by one C7000 control system - Combination of different unit sizes in one system
- Scalable airvolume adjustment for each unit
- The CyberAir Modular system consists of units !
- Benefits
- Flexible sytem for easy adaption to any site
requirement
19GE 2 - Advanced indirect free cooling
- Facts
- EC fans variable air volume in free cooling
operation - Oversized housing design of the ALD/ALU units
with reduced internal pressure drop - Frequency driven pumps Variable glycol flow
according to the required cooling capacity - Intelligent management of the stand-by capacity
through VarioLogic
- Benefits
- Maximum reduction of energy consumption
20Control system C7000
- Facts
- 31 unit control system
- BMS-protocols Modbus KP on board
- Scaleable graphical recording of temperature and
humidity between 1 and 1440 days - Event log recording the last 200 events
- Connectivity to Internet
- Benefits
- No additional costs for hardware for
BMS-connection - Documented unit reliability and precision due to
recorded room conditions and A/C events
21Filter Control Management
- Facts
- Intelligent airflow control in case of dirty
filter - A required filter change will automatically be
indicated
- Benefits
- Protection against low airflow and hot spots
22Radial electrical heater
- Facts
- Radial electrical heater positioned at the fan
discharge - Optimal heat transfer from the heater to the
airflow due to high air velocity - Minimized risk of overheating
- Benefits
- Save operation in heating mode
- High heater efficiency
2396mm zick zack filters
- Facts
- Increased filter height leads to larger filter
surface - ...reduces airflow resistance
- ...reduces absorbed fan power
- ... extends filter service intervals
- Benefits
- Reduced lifecycle costs (energy saving)
- Reduced costs for spare filters
24Small footprint with new dimensions
- Facts
- Extremely favourable proportion of footprint and
cooling capacity - Front maintenance access
- Benefits
- Save expensive footprint
- Higher cooling capacity in the data centre
25Microprocessor controlled airflow
- Facts
- Increase of airflow in case of dirty filter
- Proportional reduction of airflow in case of low
temperature - Airflow reduction during de-humidification
- Benefits
- Considerable energy savings
- Reduced noise levels
26Microprocessor controlled airflow
- Sample
- 3x ASD1500CW at 24C/50
- with 7/12C water
- incl.
- 1/3 standby capacity
Airflow 2x 29.000 m³/h Fan absorbed power
2x 8,0 16,0 kW Lpa,2m 2x 59,7dBA 62,7dBA
Standby
2x 112,1 224,2 kW net sensible
Airflow 3x 19.000 m³/h Fan absorbed power
3x 2,3 6,9 kW Lpa,2m 3x 50,8dBA 55,6dBA
3x 75,1 225,3 kW net sensible
- Benefits
- Considerable energy savings
- Reduced noise levels
gt Energy savings 9,1 kWh/year 7972
/year _at_ 0,1 /kWh
gt Noise reduction -7,1 dBA
27Proportional heater control
- Facts
- Heater capacity will be controlled proportional
depending on temperature
- Benefits
- Energy saving
- more precise temperature control
28...thank you for your attention.