Title: Aucun titre de diapositive
1(No Transcript)
2(No Transcript)
3Standard Version CD12
- Inputs 8 - 4 Digital and 4 configurable for
Digital or 10 bit Analog - Outputs4 - 8 amp Relays or 700ma Transistors (1
PWM) - 4 Line by 18 Character fully user programmable
display - 6 User configurable Buttons.
- Back-Lit Display
- Modbus Ascii Communications via programming port
- Double the memory of Millenium II
4Standard Version CD20
- Inputs 12 - 6 Digital and 6 configurable for
Digital or 10 bit Analog - Outputs8 - 8 amp Relays or 700ma Transistors (4
PWM) - 4 Line by 18 Character fully user programmable
display - 6 User configurable Buttons.
- Back-Lit Display
- Modbus Ascii Communications via programming port
- Double the memory of Millenium II
5Economy Version CB Series
- Same features as Standard Controller without
Display and Buttons - 12 and 20 I/O Models
- Cost Saving Design
- 10 bit Analog inputs on DC powered controllers
- Relay and Transistor models
- Modbus Ascii Communications via programming port
- Double the memory of Millenium II
6Expandable Version XD10
- Inputs6 - 2 Digital and 4 configurable for
Digital or 10 bit Analog - Outputs4 - 8 amp Relays or 700ma Transistors (1
PWM) - 4 Line by 18 Character fully user programmable
display - 6 User configurable Buttons.
- Back-Lit Display
- Modbus Ascii Communications via programming port
- 4 times the memory of Millenium II
- Wide array of expansion modules
7Expandable Version XD26
- Inputs16 - 10 Digital and 6 configurable for
Digital or 10 bit Analog - Outputs10 Relays(8x8a / 2x5a) or 700ma
Transistors (4 PWM) - 4 Line by 18 Character fully user programmable
display - 6 User configurable Buttons.
- Back-Lit Display
- Modbus Ascii Communications via programming port
- 4 times the memory of Millenium II
- Wide array of expansion modules
8Expansion Options
- Expand up to 50 I/O
- RS485 Modbus Communication module
- Modbus TCP/IP Ethernet Communication module
- 2 Input 2 Output 10 bit analog expansion module
- 6, 10, and 14 I/O expansion modules
- 2 modules can be added to 1 base controller
- Simplified wiring and installation of modules
9(No Transcript)
10 Expansion Modules XA03 PT100 Module XA04
Analog I/O Module
XA03
XA04
- 3 PT100 Inputs
- 10 bit resolution
- Heating Control
- Cooling Control
- 2 Analog 10 bit Inputs
- 2 Analog 10 bit Outputs
- 0-10VDC Input
- 0-20ma Input
- Direct Connection of PT100
11XN03
XN05
- Serial RS485
- Modbus RTU or Ascii
- 4 16 bit Input registers
- 4 16 bit Output registers
- Perfect for external HMIs
- Ethernet Modbus TCP/IP
- Static or Dynamic IP
- 8 16 bit Input registers
- 8 16 bit Output registers
- Easy SCADA Integration
12Communications
13 Modem Communications
M3MOD Modem Interface
- Interfaces to wired or GSM cell phone modems
- Monitor remote applications via PC or cell
phone - Send text messages to cell phones
- Control the M3 via cell phone or PC
- Using M3 Alarm software use your PC to log
alarms - Modify or download a new program remotely
14 M3 Alarm Software Screen
1 Local/Remote 2Menu Bar 3Icon
Bar 4Alarm Display
15Millenium 3 offers the largest display available
on micro-PLCs. The 4 line by 18 character
display provides the ability to add more
descriptive text to applications.
No More Abbreviations!!!
16Programming and Communications Interfaces
- Standard RS232 DB9 Programming Cable
- New USB cable- No converter required
- New Bluetooth Interface Program wirelessly
- All interfaces can be used to access the Modbus
functionality of the programming port.
17DC to DC Converters
- Input 9-18 VDC output 12 VDC
- Input 16-36 VDC output 24 VDC
- Nominal Power 10W
- For use in applications with power fluctuations
18(No Transcript)
19Millenium 3 Software Enhancements
20Software Enhancements
- Function Block Programming
- SFC Sequential Flow Control
- Combine Function Block SFC
- Ladder Logic
- Faster Cycle Time
- Create Macro Make your own functions!
- New Simulation features
21(No Transcript)
22Software Enhancements
All timers grouped into a single icon with
dynamic operation.
23Timer LI Function Block
Added function for
starting with OFF Time First
24Software Enhancements
Timers can now be configured with an external set
point. The value can come from another function
block or an Analog Input / Potentiometer.
25Software Enhancements
Timers can now be adjusted in units other than
.1s All timers can be set for a base unit of .1s
or Hours/Minutes/Seconds or based on the cycle
time of the controller.
26Software Enhancements
- The controller can now be switched into run mode
without resetting non-retained values.
27Software Enhancements
- Save values at power break added on all
function with actual values - Modification allowed added on all function
with parameters - Edit menu, added function re-do in addition
to the undo (multi-level) - Added new function block which gives
information about the state of the controller
28Software Enhancements
Data can now be sent and retrieved through the
programming port. The SL In and SL Out
function blocks give access to 48 16 bit words.
24 In and 24 Out. A PLC or PC can be used to
log data or set values in the controller
29Software Enhancements
Input and Output blocks can now be assigned a
custom icon.
30Software Enhancements
New simulation mode features allows easy
verification of Time Prog Function block events.
31Software Enhancements
Slider bars have been added to easily modify
analog values durring simulation.
32Millenium 3 Applications
33Software Enhancements