Future Cooling Solutions
In-Row Considerations for Next Generation
  • Current Design
  • Converted platform for upflow and downflow CRAC
    unit
  • kW per rack space 16.7
  • Utilizes three rack positions
  • Constant airflow design _at_ 6450 cfm
  • New Design
  • New platform with in-row in mind
  • kW per rack space 33.4
  • Utilizes ½ rack footprint _at_ 16.7 kW
  • Variable airflow design
  • Dehumidification
  • Light load conditions

3
Future Cooling Solutions
  • In-Row Enhancements
  • Twice the Cooling Density per Foot Print Area
  • Further Increase in usable IT space
  • DX Products as well as Chilled Water
  • Smaller systems
  • Modularity
  • Ease of redundancy
  • Flexible configurations
  • High Density Capable
  • Up to 60 kW/rack

4
Future Cooling Solutions InRow RC
Next Generation In-Row
  • Half Rack Wide
  • Chilled Water
  • Capacity 17kW _at_ 85 return air temp.
  • 2700 CFM
  • Variable Speed Fans
  • Modular
  • Between Racks
  • End of Row
  • Laterally Stackable High Density Redundancy
  • Dual Power Input
  • kW Metering
  • Network Manageable
  • ISX Manager Integration
  • Hot Aisle Containment

5
20 kW Per Rack Zone with current IR40
14 Rack Spaces per Hot Aisle Total cooling
capacity 300KW
6
20 kW per Rack Data Center
Total Room Space for 224 Racks 44 ft x 232
ft Total Cooling Capacity 4.8MW
7
20 kW per Rack Zone with InRow RC
22 Rack Spaces per Hot Aisle Total Air flow per
zone 54,000 CFM Total Cooling Capacity 440
kW (22 kW per unit _at_ 28 F delta T)
8
20 kW per Rack Data Center
Total Room Space for 220 Racks 44 ft x 148
ft Total Room Cooling Capacity 4.40MW
9
Future Cooling Solutions InRow RP
DX and Chilled Water
  • One Rack Wide
  • DX
  • Split System Air Cooled Product R407C
  • Capacity 25kW
  • 4000 CFM
  • CW
  • Capacity 37kW
  • 7200 CFM
  • Precision Capable
  • Dehumidify/Reheat/Humidifier
  • Critical load power input
  • kW Metering
  • Network Manageable
  • ISX Manager Integration
  • Hot Aisle Containment

DX Unit
CW Unit
10
InRow SC
  • Half Rack Width
  • Self Contained Air Cooled Product
  • Capacity 5kW - R410A
  • Brings Portable AC Sizes into In-Row Applications
  • Global Product(s)
  • SX Rack Compatible
  • Network Manageable
  • ISX Manager Integration
  • Dual Power Input

11
Future Cooling Solutions - RACS
Rack Air Containment System
  • Support IR Products
  • Hot Air Scavenging System
  • Ducted Return / Free Supply
  • Ducted Return and Supply
  • Use for High Density Applications
  • Supports InRow RC, RP, and SC
  • Environmental Containment

12
Future Cooling Solutions Cooling Distribution
Unit
CDU Cooling Distribution Unit
  • Indoor Central Distribution Unit for Single Point
    Service
  • Support up to 12 InRow RC CRAC Units
  • Utilizes Flexible Engineered Tubing
  • Isolation Balancing Valves
  • Top or Bottom Connections

13
Chiller Pump Package
  • Air Cooled Remote Chiller
  • Capacity 50kW to 220kW
  • Support 3 to 12 IR 17kW CRACs
  • Dual Pump System Integrated
  • Separate Electrical Feed for Pump
  • Water Storage Tank
  • OEM Name Brand
  • Storage Tank
  • Modbus

14
Air Removal Unit 2nd Generation
  • Rack Air Removal Unit (ARU) Generation 2
  • Redesign Effort
  • SX and VX Rack Compatible
  • Improved Serviceability
  • Reduce Cost
  • Maximize Shipping Container Volume
  • Reduce Unit Weight
  • Global Universal SKU
  • Network Manageable ISX Integration

15
FM 100 kW Precision Floor Mount
  • FM 100kW 4-Bay CW DX
  • New Design Effort
  • Fully Configured Precision AC Product CW and DX
  • Complete feature set as existing FM Product Line
  • Front Accessible only
  • Global Product
  • Network Manageable ISX Integration

16
Wrap-up
  • Significant Investment in In-Row Products
  • Developing product to support tomorrows Heat
    Densities
  • Modular, Flexible, Scaleable

17
Sales Tool Support
  • Brochures
  • Update cooling brochure
  • New InRow brochure
  • Videos
  • Update cooling products video
  • Update InRow video
  • White Papers 3 New Releases
  • Central humidification
  • Cooling architecture Row/Room/Rack (including
    overhead
  • Water piping methodologies
  • Application Notes
  • Support for all new products
  • FAQ
  • Support for all new products

18
Sales Tool Support
  • Performance Program
  • Web based, chilled water interpolated performance
  • Submittal sheets for specific design points
  • Presentations
  • 8/1 Slide overviews
  • Technical presentations
  • Case Studies
  • TCO analysis Internal and external
  • Real customer write-up
  • Paper dolls
  • InRow Planning guide
  • Site prep, best practices and layout
  • ISX Designer
  • Support for InRow RC, Chilled Water Distribution,
    ARU, WCVU, RACS

19
Sales Tools Support
  • Technical Data Manuals
  • InRow RC, CDU
  • Competitive Comparisons
  • Head to head product comparisons
  • How to Sell documents

20
(No Transcript)
Write a Comment
User Comments (0)
About PowerShow.com