Title: LAT EMI Test
1LAT EMI Test
- LAT test levels derived from LAT-SS-0778
- Use CAL EMI test procedure as template
- LAT-PS-03929-03
- Test Suite
- CE102 Conducted Emissions, Power Leads, 10 kHz to
10 MHz, MIL-STD-462, CE03 - CECM Conducted Emissions, Time Domain, 150 MHz
Bandwidth - CS102 Conducted Susceptibility, Power Leads, 10
kHz to 10 MHz, MIL-STD-462, CS02 - CSCM Conducted Susceptibility, Common Mode, 30 Hz
to 150 MHz, MIL-STD-462, CS02 - CS06 Conducted Susceptibility, Spike, Power
Leads, MIL-STD-462 - RE101 Radiated Emissions, Magnetic Field, 20 Hz
to 50 kHz - RE102 Radiated Emissions, Electric Field, 10 kHz
to 18 GHz, MIL-STD-461E - RS101 Radiated Susceptibility, Magnetic Field, 20
Hz to 50 kHz - RS103 Radiated Susceptibility, Electric Field, 30
MHz to 18 GHz
2LAT Power Interfaces
- SC-LAT Power Interfaces
- SC PRU (P) - LAT PDU
- SC PRU (R) - LAT PDU
- SC PRU (P) - LAT SIU (P)
- SC PRU (R) - LAT SIU (R)
- SC PRU (P) - LAT VCHP Y
- SC PRU (P) - LAT VCHP -Y
- SC PRU (R) - LAT VCHP Y
- SC PRU (R) - LAT VCHP -Y
- SC PDU (P) - LAT MAKEUP
- SC PDU (R) - LAT MAKEUP
3Test Limitations
- RS103 upper limit of 18GHz (40GHz)
- Limited area of RS101 test
- Requires scanning each 10cm x 10cm area,
16min/scan - 1450 scans for the LAT, another 1200 for the
radiators (29 days) - Scan selected locations around connectors, PMTs,
BEA - Limited B side conducted testing
- Emissions tests and susceptibility only where
noted on A side - Limited VCHP htr testing
- Emissions only
4EMI Test Configurations
- Split EMI test
- Conducted tests performed in the high bay
integration area - Radiated testing performed in anechoic chamber
- Conducted emissions and susceptibility tests with
SIU and PDU do not require radiators, but do
require good access to connectors
- LAT z axis vertical to provide access to LAT
connectors with 2m cable lengths
5Radiated Test Configuration
6Radiated Test Configuration
7LAT Cable Feedthrough
8Conducted Test Considerations
- Fully test
- SC PRU (P) - LAT PDU
- SC PRU (P) - LAT SIU (P)
- Limited test
- SC PRU (R) - LAT PDU
- SC PRU (R) - LAT SIU (R)
- Need to resolve operating constraints on VCHP
htrs - Can they be run for extended periods of time at
ambient temp? - Thermostatic overtemp protection
- Limited power, 4W/circuit
- No plan to test PDU - LAT Makeup
- Thermostatic control, open circuit at ambient
temp - Conducted susceptibility tests may require
disabling bus protection unit
9Conducted Test Harness
- Require access to power harness 2m from LAT I/F
- CE102, CS102 (10kHz - 150kHz), CSCM (30Hz -
150kHz), CECM - All conductors of power circuit must be connected
to a single 1/4 lug on line conditioner - All conductors must be gathered into a bundle so
that a current probe may be connected around them - Require access to power harness 5cm for LAT I/F
- CS102 (150kHz - 150MHz), CS06, CSCM (150kHz -
150MHz) - Small bare section of a single conductor to
attach clip lead for hf injection - EMI shielding not required on harnesses
10Radiated Test Harness
- No access to conductors required
- Harness must be fully shielded
- Includes all connector savers
- Any test ports must be closed out or have
shielded harnesses - back door
- Test harnesses must be shielded
- Accelerometers
- TCs thermistors
- Harness supports not directly connected to the
LAT should be nonconducting material, wood or PVC
11Test Software
- Emissions Testing
- Utilize the FSW Charge Injection Calibration
function to inject charge into a large number of
detectors. The number of channels into which
charge can be injected will be limited by a) FSW
design (which is not yet complete) and b) The
number of channels which can physically be
injected with charge in any given one second
cycle. The one second cycle is required to
provide repeatability during the Emissions
frequency sweeps. - Susceptibility Testing
- A variation of the test described in the
End-to-End (ETE) Test Plan, LAT-MD-03489,
paragraph 2.2.1, item 4, "Nominal Rate Cosmic Ray
Test" will be used. This test is run at ambient
temperature and at nominal voltage, timing,
threshold, and trigger configurations. Both
Cosmics and the external trigger function are
used to create on-orbit trigger rates. The
external trigger rate will be set so that the
total trigger rate will be at or near the nominal
expected on-orbit values. - The externally triggered events should have very
low occupancy, monitor to see if occupancy goes
up - The cosmic ray events should remain constant,
monitor to see if rate goes up.
12Test EGSE Software Tools
- Displays of natural trigger rates and occupancy
of externally triggered events should be strip
chart type - Other error status, checksum, etc. should latch
13RE102 - Integrated LAT
14RE101 All LAT Equipment
15CE102 Spacecraft PRU LAT DAQ
16CE102 Spacecraft PRU LAT SIU (IL), VCHP Heaters
17CE102 Spacecraft PDU LAT Anti-freeze and
Make-up Heaters
18Conducted Emissions Common Mode All LAT
Equipment
19RS103 Perform BEA and Tracker Tower
20RS101 Perform BEA and Tracker Tower
21CS102 Spacecraft PRU LAT DAQ
22CS102 Spacecraft PRU LAT SIU (IL), VCHP Heaters
23CS102 Spacecraft PDU LAT Anti-freeze and
Make-up Heaters
24Conducted Susceptibility Common Mode All LAT
Equipment
25CS06 Operate All LAT Equipment
26CS06 Perform All LAT Equipment
27(No Transcript)
28Back-up Slides
29CE 102 LAT PDU TPS (TEM, CAL, TRKR), EPU
(IL),GASU (ACD BEA, IL), PDU (IL)
30CS102 LAT PDU TPS (TEM, CAL, TRKR), EPU
(IL),GASU (ACD BEA, IL), PDU (IL)