LIST Vorstellung - PowerPoint PPT Presentation

1 / 25
About This Presentation
Title:

LIST Vorstellung

Description:

Control and evaluation unit, with total front-panel control, ... Tunnels: Benelux LISTEC GmbH. E-mail: LISTEC_at_t-online.de. Reference List. Further Tunnels ... – PowerPoint PPT presentation

Number of Views:48
Avg rating:3.0/5.0
Slides: 26
Provided by: hbal
Category:

less

Transcript and Presenter's Notes

Title: LIST Vorstellung


1
LIST
Welcome to the information pages of the LIST
linear fire detection system
2
Sensor Control Unit SCU 3000
Control and evaluation unit, with total
front-panel control, for fire detection in
special applications.
3
Sensor Control Unit SCU 2000
Control and evaluation unit with all the
necessary control for fire detection in special
applications.
4
Sensor Control Unit SCU 800
Control and evaluation unit for digital sensors
in applications such as covered parking, false
ceilings etc.
5
Sensor Control Unit SCM 4000
Master control unit controls up to 8 slave units
as far as 4km apart.
6
Sensor Control Unit SCS 4010
Slave control with up to 2 500m sensor cable for
connection to the LIST star network.
7
Differential Alarms
Freely adjustable differential alarm threshold,
e.g. 3,4º
º C
4
Differential alarm
Temperature
3
2
Pre-alarm at 50 of the threshold
1
0
10
20
30
40
50
60
t
Measuring cycle no.
8
Reference Profiles
C
40
30
Temperature
20
Reference value
10
0
t
10
30
50
60
20
40
Time (minutes)
9
Maximum TemperatureAlarms
Freely adjustable absolute alarm threshold, e.g.
50ºC
  • Absolutalarmschwelle frei definierbar, z.B. 70,0
    C

º C
80
60
Absolute alarm
Temperature
Pre-alarm at 90 of the threshold
40
20
0
1
2
6
3
4
5
t
Measuring cycle no.
10
Frost Alarms
º C
Measuring cycle no.
10
0
4
1
3
5
6
2
t
Temperature
-10
Pre-alarm at 5 over threshold
-20
UT-Alarm (frost alarm)
-30
Freely adjustable minimum temperature threshold,
e.g.. - 25,0 C
11
Software LISTgraph II
LISTgraph II Graphic program for WINDOWS incl.
LISTTERM LISTterm Terminal- and
commissioning program for PCs,.
Alarm / Fault
No fault
Fire
Legend
Fire terminal station
Sensor control unit
3
/
2
1
1
/
6
1
/
5
2
/
1
1
2
/
1
2
2
/
1
3
1
/
4
3
/
2
0
3
/
2
2
Sensor cable with measuring point
1
/
7
2
/
1
0
Path for fire brigade
2
/
1
4
1
/
3
3
/
2
3
Entry / Exit
1
/
8
2
/
9
Current position
2
/
1
3
/
2
4
1
/
2
5
3
/
1
8
4 Alarm section 37 Sensor no.
4
/
3
7
LIST
2
/
1
6
1
/
1
3
/
1
7
3
/
2
5
Fire Detection
4
/
3
4
4
/
3
3
4
/
3
7
4
/
3
6
4
/
3
5
4
/
3
2
Covered parking
4
/
2
9
4
/
2
7
4
/
3
1
4
/
3
0
4
/
2
8
LISTEC GmbH
4
/
2
6
Münchenerstr.58
84424 Isen
12
Test Fire in a Tunnel
13
Test fire in a tunnel with 10m/s wind speed
14
Cold Storage at - 28 C
15
SEC 20Sensor Cable
Measuring range -40C ... 200C Operating
temp. range -40C ... 85C Resolution 0,1 Me
asuring cycle 10 sec / 312 sensors
Diameter approx. 18 mm Bending
Radius min. 30 cm Cable Length lt 2500 m /
SCU Marking each sensor
16
Reference ListTunnels Germany
17
Reference ListTunnels Austria
18
Reference ListTunnels Switzerland
19
Reference ListTunnels Benelux
20
Reference ListFurther Tunnels
21
Reference ListConveying systems
22
Reference ListMetro Marshalling Yards
23
Reference ListCable Trays
24
Reference ListFurther References
25
Good Bye
We hope that this presentation has awakened your
interest in this unique fire detection system
for special applications.
Give your LISTEC team a call!
Write a Comment
User Comments (0)
About PowerShow.com